Left bundle branch area pacing in children: case series

被引:0
作者
Jedrzejczyk-Patej, Ewa [1 ]
Mazurek, Michal [1 ]
Kowalski, Oskar [2 ,3 ]
Szulik, Mariola [1 ,4 ]
Tyc, Filip [5 ]
Pietruczuk, Armin [6 ]
Lenarczyk, Radoslaw [7 ,8 ]
Kalarus, Zbigniew [7 ,8 ]
机构
[1] Silesian Ctr Heart Dis, Dept Cardiol Congenital Heart Dis & Electrotherap, Sklodowskiej Curie 9, PL-41800 Zabrze, Poland
[2] Med Univ Silesia, Fac Hlth Sci, Dept Human Nutr, Poniatowskiego 15, PL-40055 Katowice, Poland
[3] Med Univ Silesia, Fac Hlth Sci, Dept Dietet, Katowice, Poland
[4] WSB Univ, Dept Med & Hlth Sci, Fac Appl Sci, Cieplaka 1c, PL-41300 Daabrowa Gornicza, Poland
[5] Med Univ Silesia, Fac Med Sci Zabrze, Dept Pediat Cardiol & Congenital Heart Dis, Poniatowskiego 15, PL-40055 Katowice, Poland
[6] Silesian Ctr Heart Dis Zabrze, Dept Congenital Heart Dis & Pediat Cardiol, Sklodowskiej Curie 9, PL-41800 Zabrze, Poland
[7] Med Univ Silesia, Div Med Sci Zabrze, Katowice, Poland
[8] Silesian Ctr Heart Dis, Dept Cardiol, Sklodowskiej Curie 9, PL-41800 Zabrze, Poland
关键词
Case series; Children; Left bundle branch area pacing; Conduction system pacing; Pacing; PREDICTORS;
D O I
10.1093/ehjcr/ytaf020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Left bundle branch area pacing (LBBAP) is a new concept that provides physiological pacing with a narrow QRS duration. Recently published data suggest that LBBAP may prevent deleterious effects of right ventricular pacing, namely pacemaker-induced cardiomyopathy, especially in patients with expected high ventricular pacing burden, which may be of particular importance in children.Case summary Herein, we report successful implantation of Medtronic SelectSecure (Model 3830, Medtronic Inc.) right ventricle electrode in the region of left bundle branch area in three consecutive children (two 16-year-old and one 8-year-old). Indication for pacemaker implantation was third-degree atrioventricular block in all cases. Implantations were performed under general anaesthesia, and there were no acute complications. During the median follow-up of 6 months, there were no adverse events and the electrical parameters of the device remained stable.Discussion Compared with adult patients, implantation of pacemakers in children may still be challenging, not only because of smaller body size but also due to continuing growth and a higher rate of lead and device-related complications. We have demonstrated that implantation of LBBAP in children is feasible and could be worth considering, particularly in patients with expected high ventricular pacing burden. Further studies are needed to assess the efficacy and safety of LBBAP in children during long-term observation.
引用
收藏
页数:7
相关论文
共 16 条
[1]  
Burri H, 2023, EUROPACE, V25, P1208, DOI 10.1093/europace/euad043
[2]   Conduction system pacing in pediatric and congenital heart disease [J].
Chubb, Henry ;
Mah, Douglas ;
Dubin, Anne M. ;
Moore, Jeremy .
FRONTIERS IN PHYSIOLOGY, 2023, 14
[3]   Progressive QRS Duration and Ventricular Dysfunction in Pediatric Patients with Chronic Ventricular Pacing [J].
Czosek, Richard J. ;
Gao, Zhiqian ;
Anderson, Jeffrey B. ;
Knilans, Timothy K. ;
Ollberding, Nicholas J. ;
Spar, David S. .
PEDIATRIC CARDIOLOGY, 2021, 42 (02) :451-459
[4]   Preliminary study on left bundle branch area pacing in children: Clinical observation of 12 cases [J].
Dai Wenlong ;
Guo Baojing ;
Dai Chencheng ;
Dong Jianzeng .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (07) :1558-1566
[5]   Predictors of left ventricular remodelling and failure in right ventricular pacing in the young [J].
Gebauer, Roman A. ;
Tomek, Viktor ;
Salameh, Aida ;
Marek, Jan ;
Chaloupecky, Vaclav ;
Gebauer, Roman ;
Matejka, Tomas ;
Vojtovic, Pavel ;
Janousek, Jan .
EUROPEAN HEART JOURNAL, 2009, 30 (09) :1097-1104
[6]   Conduction System Pacing in Pediatrics and Congenital Heart Disease, a Single Center Series of 24 Patients [J].
Gordon, Amanda ;
Jimenez, Erick ;
Cortez, Daniel .
PEDIATRIC CARDIOLOGY, 2024, 45 (06) :1165-1171
[7]   LONG-TERM PERFORMANCE OF ENDOCARDIAL PACING LEADS [J].
HELGUERA, ME ;
MALONEY, JD ;
PINSKI, SL ;
WOSCOBOINIK, JR ;
WILKOFF, BL ;
CASTLE, LW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (01) :56-64
[8]   A Novel Pacing Strategy With Low and Stable Output: Pacing the Left Bundle Branch Immediately Beyond the Conduction Block [J].
Huang, Weijian ;
Su, Lan ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Ellenbogen, Kenneth A. .
CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (12) :1736.e1-1736.e3
[9]   Left bundle branch area pacing outcomes: the multicentre European MELOS study [J].
Jastrzebski, Marek ;
Kielbasa, Grzegorz ;
Cano, Oscar ;
Curila, Karol ;
Heckman, Luuk ;
De Pooter, Jan ;
Chovanec, Milan ;
Rademakers, Leonard ;
Huybrechts, Wim ;
Grieco, Domenico ;
Whinnett, Zachary, I ;
Timmer, Stefan A. J. ;
Elvan, Arif ;
Stros, Petr ;
Moskal, Pawel ;
Burri, Haran ;
Zanon, Francesco ;
Vernooy, Kevin .
EUROPEAN HEART JOURNAL, 2022, 43 (40) :4161-+
[10]   Physiology-based electrocardiographic criteria for left bundle branch capture [J].
Jastrzebski, Marek ;
Kiebasa, Grzegorz ;
Curila, Karol ;
Moskal, Pawe ;
Bednarek, Agnieszka ;
Rajzer, Marek ;
Vijayaraman, Pugazhendhi .
HEART RHYTHM, 2021, 18 (06) :935-943