Evaluation of Microleakage of Orthograde Root-Filling Materials in Immature Permanent Teeth

被引:0
作者
Das, Upma [1 ]
Gautam, Vanita [1 ]
Shubham, Snigdha [1 ]
Raut, Shristi [2 ]
机构
[1] Universal Coll Med Sci, Dept Conservat Dent & Endodont, Bhairahawa, Nepal
[2] Universal Coll Med Sci, Dept Microbiol, Bhairahawa, Nepal
关键词
adseal; apical microleakage; biodentine; dye penetration; fluorescence; MTA; MTA plus; open apex; root-end filling; MINERAL TRIOXIDE AGGREGATE; IN-VITRO EVALUATION; APICAL PLUG; SEALING ABILITY; ENDODONTIC SURGERY; APEXIFICATION; BIODENTINE; CALCIUM; MODEL;
D O I
10.1155/2024/8867854
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Introduction: The absence of a barrier in an open root apex makes endodontic treatment challenging as root-filling material can easily reach the surrounding tissue. The aim of the study was to compare the apical microleakage associated with mineral trioxide aggregate (MTA), biodentine, custom-made gutta-percha with MTA plus and custom-made gutta-percha with Adseal in immature permanent teeth by dye penetration method. Methods: Apical 2 mm of 60 single-rooted mandibular premolar teeth was resected to create divergent open apices and 10 teeth each were filled with Biodentine plug, MTA plug, custom-made gutta-percha with MTA plus sealer and custom-made gutta-percha with Adseal sealer. Ten teeth each acted as positive and negative controls. All the samples were stored at 37 degrees C at 100% humidity for 5 weeks and then immersed in 2% Rhodamine B dye for 24 h. Transverse sectioning was done apically at 1 mm and 3 mm to evaluate dye penetration under a fluorescence microscope using ImageJ software. Results: There was a significantly greater microleakage at 1 mm cross section compared to 3 mm (p<0.0001). At 1 mm cross section, the apical microleakage was the highest for the MTA plug with a mean leakage percentage of 48.08 +/- 16.38, a mean depth of leakage of 0.46 +/- 0.10 mm and a mean area of leakage of 1.35 +/- 0.74 mm2, compared to other groups, and the difference was statistically significant. However, at a 3 mm cross section, MTA plus sealer with gutta-percha demonstrated the highest mean leakage percentage (25.01 +/- 7.77) compared to other groups and the difference was statistically significant (p=0.03). Conclusion: It can be concluded that the 3-mm-thick apical plug provided better sealing of the open apex compared to the 1 mm apical plug and there was no significant difference in microleakage among the Biodentine plug, MTA plug and Adseal sealer with gutta-percha plug at 3 mm cross section.
引用
收藏
页数:10
相关论文
共 57 条
  • [1] Abbas Akhila, 2020, Int J Clin Pediatr Dent, V13, P656, DOI 10.5005/jp-journals-10005-1853
  • [2] Adel Mamak, 2021, J Dent (Shiraz), V22, P290, DOI 10.30476/DENTJODS.2020.85876.1157
  • [3] In-vitro evaluation of microleakage of an orthograde apical plug of mineral trioxide aggregate in permanent teeth with simulated immature apices
    Al-Kahtani, A
    Shostad, S
    Schifferle, R
    Bhambhani, S
    [J]. JOURNAL OF ENDODONTICS, 2005, 31 (02) : 117 - 119
  • [4] Alani AH, 1997, OPER DENT, V22, P173
  • [5] Alhabdan AA., 2017, Journal of International Oral Health, DOI [10.4103/jioh.jioh16017, DOI 10.4103/JIOH.JIOH16017]
  • [6] Arikatla Sampath Kumar, 2018, J Conserv Dent, V21, P373, DOI 10.4103/JCD.JCD_64_18
  • [7] Ballullaya SV, 2017, J CLIN DIAGN RES, V11, pZC65, DOI 10.7860/JCDR/2017/25780.10077
  • [8] Efficacy of Biodentine as an Apical Plug in Nonvital Permanent Teeth with Open Apices: An In Vitro Study
    Bani, Mehmet
    Sungurtekin-Ekci, Elif
    Odabas, Mesut Enes
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [9] Bansal R., 2019, Dental Journal of Advance Studies, V07, P006, DOI [10.1055/s-0039-1684154, DOI 10.1055/S-0039-1684154]
  • [10] Butt Naziya, 2014, Indian J Dent Res, V25, P692, DOI 10.4103/0970-9290.152163