EXPERIMENTAL INVESTIGATION OF LOW HEAT FLUX WICKED HEAT PIPES PERFORMANCE WITH DIFFERENT WORKING FLUIDS AND TILT ANGLES

被引:0
|
作者
Sertkaya, Ahmet Ali [1 ]
Akyar, Yusuf [2 ]
Ozsoy, Ahmet [3 ]
机构
[1] Selcuk Univ, Fac Technol, Dept Mech Engn, Konya, Turkiye
[2] Selcuk Univ, Inst Sci, Dept Mech Engn, Konya, Turkiye
[3] Isparta Univ Appl Sci, Fac Technol, Dept Mech Engn, Isparta, Turkiye
关键词
heat pipe; two-phase closed thermosyphon; working fluid; thermal resistance; heat transfer coefficient; 2-PHASE CLOSED THERMOSIPHON; THERMAL PERFORMANCE; EVAPORATOR; COLLECTOR; RATIO;
D O I
10.1615/HeatTransRes.2024053190
中图分类号
O414.1 [热力学];
学科分类号
摘要
This experimental investigation focused on wicked heat pipe under different operating conditions. A single-layer 150- mesh wicked heat pipe was used in the experiments. The heat pipes were made of copper tubes with a diameter of 15 mm and a total length of 450 mm. The used working fluids were pure water, methanol, ethanol, acetone, and R134a. The working fluid charge rate was 50% of the evaporator volume. The power input from the evaporator surface was selected from five different values between 1.12 kW/m2 and 5.58 kW/m2, which can be considered as relatively low. The heat carried by the heat pipe was transferred to the water circulating around the condenser section. The heat pipes were operated at inclination angles of 0 degrees, 30 degrees, 60 degrees, and 90 degrees, and the performance was assessed based on the thermal input power and tilt angle. Over the range studied, the best performance in terms of heat pipe surface temperature distributions was achieved with R134a. Heat pipe performance was improved with increasing tilt angle. Increasing the tilt angle also increased the boiling heat transfer coefficient. The gradual increase in heat flux was observed to result in an average increase of 10-15 degrees C in surface temperatures in the evaporator section compared to the previous stage. The heat transfer coefficient by boiling increased with the increase in the tilt angle and heat input power. This increase was 67.54% for R134a at a heat input of 1.12 kW/m2 and a tilt angle of 90 degrees. The increase amounted to 214.43% for 5.58 kW/m2 heat input.
引用
收藏
页码:69 / 83
页数:16
相关论文
共 50 条
  • [21] Visualization and Heat Transfer Performance of Mini-Grooved Flat Heat Pipe Filled with Different Working Fluids
    Xin, Fei
    Lyu, Qiang
    Tian, Wenchao
    MICROMACHINES, 2022, 13 (08)
  • [22] Experimental investigation of thermal performance of metal foam wicked flat heat pipe
    Dhanabal, Somasundaram
    Annamalai, Mani
    Muthusamy, Kamaraj
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 82 : 482 - 492
  • [23] Theoretical and experimental investigation of the startup characteristics of cryogenic loop heat pipes
    Zhao, Chenyang
    Li, Nanxi
    Li, Junting
    Jiang, Zhenhua
    Wu, Yinong
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 201
  • [24] Investigaing thermal performance of a partly sintered-wick heat pipe filled with different working fluids
    Khalili, M.
    Shafii, M. B.
    SCIENTIA IRANICA, 2016, 23 (06) : 2616 - 2625
  • [25] Experimental study on heat transfer properties of gravity heat pipes in single/hybrid nanofluids and inclination angles
    Wang, Zhaoxiao
    Zhang, Hui
    Yin, Lei
    Yang, Di
    Yang, Gang
    Akkurt, Nevzat
    Liu, Dinghai
    Zhu, Lidong
    Qiang, Yujie
    Yu, Fan
    Xu, Qian
    Xiong, Yaxuan
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 34
  • [26] AN EXPERIMENTAL INVESTIGATION ON THE HEAT TRANSFER COEFFICIENT OF OSCILLATING HEAT PIPES
    Gao, Ling
    Geng, Wenguang
    Ma, Xiaoxu
    Ma, Xiuli
    Luo, Guangliang
    Li, Xuanyou
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 78 - 82
  • [27] Experimental investigation of indirect solar dryer integrated with wicked heat pipe
    Sachithanandhan, Vismaya K.
    Monicka, A. Asha
    Solomon, A. Brusly
    Jeevarathinam, G.
    Yadav, Tanmay
    Ajith, R.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (08) : 4397 - 4408
  • [28] An experimental inquisition of waste heat recovery in electronic component system using concentric tube heat pipe heat exchanger with different working fluids under gravity assistance
    Ramkumar, P.
    Sivasubramanian, M.
    Raveendiran, P.
    Kanna, P. Rajesh
    MICROPROCESSORS AND MICROSYSTEMS, 2021, 83
  • [29] Visualization and performance measurement of operating mesh-wicked heat pipes
    Wong, Shwin-Chung
    Kao, Yi-Huan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (17-18) : 4249 - 4259
  • [30] Experimental investigation of pulsating heat pipes with different evaporator roughness values
    Frey, Yannick
    Doerr, Aaron
    Lorenz, Marco
    APPLIED THERMAL ENGINEERING, 2023, 233