Measure of negative ion density in a large negative ion source using Langmuir probes

被引:1
作者
Poggi, C. [1 ]
Spolaore, M. [1 ]
Barbisan, M. [1 ]
Brombin, M. [1 ]
Cavazzana, R. [1 ]
Marconato, N. [1 ,2 ]
Pasqualotto, R. [1 ]
Pimazzoni, A. [1 ]
Sartori, E. [1 ,2 ]
Serianni, G. [1 ]
机构
[1] Univ Padua, Consorzio RFX, ENEA, INFN,Acciaierie Venete SpA,CNR, Corso Sati Uniti 4, I-35127 Padua, Italy
[2] Univ Padua, Via 7 Febbraio 2, I-35122 Padua, Italy
关键词
Plasma diagnostics - probes; Ion sources (positive ions; negative ions; electron cyclotron resonance (ECR); electron beam (EBIS));
D O I
10.1088/1748-0221/18/08/C08013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutral Beam Injectors (NBIs) based on negative ions are the workhorses of future fusion reactors, such as ITER, which they are expected to provide with up to 33 MW of power to heat the fusion plasma. The negative hydrogen ions are extracted from a RF plasma, in which a magnetic filter field cools down the electrons reaching the so-called expansion region and allows the formation and survival of negative ions near the apertures in the plasma grid. To further improve the production of negative ions, cesium is usually evaporated inside the source and deposited onto the plasma walls, reducing the work function of the surfaces. This dramatically increases the density of negative hydrogen ions near the surfaces, causing the transition to an electronegative plasma in the vicinity of the plasma grid. This condition can be observed with Langmuir probes, which can then be used to provide a local meaurement of negative ion density in the ion source. In this paper we use the measurements provided by the Langmuir probe sensors embedded in the plasma grid of SPIDER, the prototype ion source of ITER NBIs, to determine the density of negative ions. A fitting method based on the determination of the collection area of the different plasma species is proposed and adapted to SPIDER experimental condition, taking into account the shape of the probes and the local topology of the magnetic field. The method is then applied to the experimental data, determining the densities of the positive and negative ions and of the electrons during a plasma pulse. Finally, a vertical array of four probes in the plasma grid is used to assess the vertical profile of plasma parameters.
引用
收藏
页数:12
相关论文
共 18 条
[1]   Development and first operation of a cavity ring down spectroscopy diagnostic in the negative ion source SPIDER [J].
Barbisan, M. ;
Pasqualotto, R. ;
Agnello, R. ;
Pilieci, M. ;
Serianni, G. ;
Taliercio, C. ;
Cervaro, V ;
Rossetto, F. ;
Tiso, A. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05)
[2]   Langmuir probe analysis in electronegative plasmas [J].
Bredin, Jerome ;
Chabert, Pascal ;
Aanesland, Ane .
PHYSICS OF PLASMAS, 2014, 21 (12)
[3]   Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions) [J].
Brombin, M. ;
Spolaore, M. ;
Serianni, G. ;
Pomaro, N. ;
Taliercio, C. ;
Dalla Palma, M. ;
Pasqualotto, R. ;
Schiesko, L. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11)
[4]  
Chabert P, 2011, PHYSICS OF RADIO-FREQUENCY PLASMAS, P1, DOI 10.1017/CBO9780511974342
[5]  
Fadone M., 2023, Summary of caesium evaporation and deposition during SPIDER first campaign, submitted to JINST
[6]   Overview of the design of the ITER heating neutral beam injectors [J].
Hemsworth, R. S. ;
Boilson, D. ;
Blatchford, P. ;
Dalla Palma, M. ;
Chitarin, G. ;
de Esch, H. P. L. ;
Geli, F. ;
Dremel, M. ;
Graceffa, J. ;
Marcuzzi, D. ;
Serianni, G. ;
Shah, D. ;
Singh, M. ;
Urbani, M. ;
Zaccaria, P. .
NEW JOURNAL OF PHYSICS, 2017, 19
[7]  
Lieberman MA, 2005, PRINCIPLES OF PLASMA DISCHARGES AND MATERIALS PROCESSING, 2ND EDITION, P1
[8]   Numerical and Experimental Assessment of the New Magnetic Field Configuration in SPIDER [J].
Marconato, Nicolo ;
Sartori, Emanuele ;
Serianni, Gianluigi .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2022, 50 (11) :3884-3889
[9]   Langmuir Probes as a Tool to Investigate Plasma Uniformity in a Large Negative Ion Source [J].
Poggi, Carlo ;
Spolaore, Monica ;
Brombin, Matteo ;
Cavazzana, Roberto ;
Fadone, Michele ;
Pasqualotto, Roberto ;
Pimazzoni, Antonio ;
Pomaro, Nicola ;
Sartori, Emanuele ;
Serianni, Gianluigi ;
Taliercio, Cesare .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2022, 50 (11) :3890-3896
[10]   Characterization of the SPIDER Cs oven prototype in the CAesium Test Stand for the ITER HNB negative ion sources [J].
Rizzolo, Andrea ;
Barbisan, Marco ;
Bizzotto, Luisa ;
Capobianco, Roberto ;
De Muri, Michela ;
Fadone, Michele ;
Ghiraldelli, Raffaele ;
Gorno, Sophie ;
Laterza, Bruno ;
Marchiori, Giuseppe ;
Marcuzzi, Diego ;
Migliorato, Luisa ;
Molon, Federico ;
Ravarotto, Diego ;
Rizzieri, Roberto ;
Rossetto, Federico ;
Sartori, Emanuele ;
Serianni, Gianluigi ;
Veltri, Pierluigi .
FUSION ENGINEERING AND DESIGN, 2019, 146 :676-679