Wall heating effect modelling for street canyon environment prediction: Experimental and numerical investigation

被引:0
作者
Li, Shitong [1 ]
Han, Jialong [1 ]
Liu, Tianxiang [1 ]
Wang, Jiaqi [1 ]
Tan, Zijing [1 ]
机构
[1] Changan Univ, Dept Architecture & Civil Engn, Xian 710064, Peoples R China
基金
中国国家自然科学基金;
关键词
Urban street canyon; Water channel; Surface heating; Coupling effect; Airflow patterns; WIND-TUNNEL; BUOYANT FLOWS; POLLUTANT DISPERSION; BUILDINGS; IMPACT; CFD;
D O I
10.1016/j.buildenv.2025.112873
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wall heating effect has been demonstrated to be a significant factor for street canyon microclimate. To improve the accuracy and practicality of street canyon microclimate prediction, multiple surface heating schemes with the consideration of both steady and unsteady wall heating effect are provided based on measured data. Numerical simulations were performed to investigate the wall heating effect on urban street canyon environment under all these modelling schemes. A scale-down water channel experimental system was established for flow field observation and model validation. Ri and Gr number was adopted for quantitative evaluation of wall heating effect. The experimental and numerical results demonstrate that wall heating scheme profoundly affect airflow patterns and thermal environment inside street canyons. Without considering the coupling thermal effect of street canyon surfaces, buoyant flow could be underestimated in steady single-surface heating assumption especially for ground and leeward wall heating conditions. With the combined heating of ground and leeward wall, airflow rotation would be enhanced, velocity near the leeward wall and upper outflow regions in a street canyon would be increased, when the Ri < -10.5 on the ground or the Gr > 1.16 x 10(12) on the leeward, the velocity distribution is relatively stable. In contrast with steady modelling schemes, less vortices occur under continuous unsteady surface heating conditions. Due to the accurate prediction, numerical model with unsteady multi-surface heating scheme is suggested for street canyon environment assessment. The findings underscore the critical role of coupling thermal effect in shaping street canyon microclimates, providing insights for environment optimizing in dense cities.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Numerical investigation of the thermal effect on flow and dispersion of rooftop stack emissions with wind tunnel experimental validations
    Huang, Yuan-Dong
    Xu, Nuo
    Ren, Su-Qi
    Qian, Li-Bing
    Cui, Peng-Yi
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (09) : 11618 - 11636
  • [42] Dispersion study in a street canyon with tree planting by means of wind tunnel and numerical investigations - Evaluation of CFD data with experimental data
    Gromke, Christof
    Buccolieri, Riccardo
    Di Sabatino, Silvana
    Ruck, Bodo
    [J]. ATMOSPHERIC ENVIRONMENT, 2008, 42 (37) : 8640 - 8650
  • [43] Numerical coupling model to compute the microclimate parameters inside a street canyon Part II: Experimental validation of air temperature and airflow
    Athamena, Khaled
    Sini, Jean-Francois
    Rosant, Jean-Michel
    Guilhot, Julien
    [J]. SOLAR ENERGY, 2018, 170 : 470 - 485
  • [44] Experimental investigation of mixed and forced convection generated by displacement ventilation with radiant wall heating
    Camci, Muhammet
    Karakoyun, Yakup
    Acikgoz, Ozgen
    Dalkilic, Ahmet Selim
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 139
  • [45] Numerical and Experimental Investigation of the Influence of External Wall Moisture on Building Temperature Distributions
    Urzedowski, Arkadiusz
    Zaburko, Jacek
    Glen, Piotr
    Lagod, Grzegorz
    [J]. ADVANCES IN SCIENCE AND TECHNOLOGY-RESEARCH JOURNAL, 2021, 15 (03) : 297 - 308
  • [46] Numerical Investigation of the Wall Effect on Airborne Particle Dispersion in a Test Chamber
    Jin, Hanhui
    He, Chao
    Lu, Lin
    Fan, Jianren
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2013, 13 (02) : 786 - 794
  • [47] Experimental investigation of a Recursive Modelling MPC system for space heating within an occupied domestic dwelling
    Rogers, Dan
    Foster, Martin
    Bingham, Chris
    [J]. BUILDING AND ENVIRONMENT, 2014, 72 : 356 - 367
  • [48] Experimental and numerical investigation of PCM capsules as insulation materials inserted into a hollow brick wall
    Abbas, Hayder M.
    Jalil, Jalal M.
    Ahmed, Sabah T.
    [J]. ENERGY AND BUILDINGS, 2021, 246
  • [49] Numerical and Experimental Investigation on the Effect of Swirl Brakes on the Labyrinth Seals
    Sun, Dan
    Wang, Shuang
    Fei, Cheng-Wei
    Ai, Yan-Ting
    Wang, Ke-Ming
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2016, 138 (03):
  • [50] Experimental and Numerical Investigation of Coating Effect on Pump Impeller and Volute
    Kocaaslan, O.
    Ozgoren, M.
    Aksoy, M. H.
    Babayigit, O.
    [J]. JOURNAL OF APPLIED FLUID MECHANICS, 2016, 9 (05) : 2475 - 2487