Flexural strength, surface roughness, and color stability of various CAD-CAM denture teeth materials

被引:0
|
作者
Orgev, Ahmet [1 ]
Cakmak, Gulce [2 ]
Peng, Chin-chun [3 ]
Lavrentiadis, Grigoris [4 ]
Li, Rui [1 ]
机构
[1] SUNY Buffalo, Sch Dent Med, Dept Restorat Dent, 235 Squire Hall,3435 Main St, Buffalo, NY 14214 USA
[2] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[3] Univ Washington, Dept Restorat Dent, Seattle, WA USA
[4] Prosthodont & Implantol Tsimiski 111, Thessaloniki, Greece
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2024年
关键词
denture teeth; flexural strength; surface roughness; thermocycling; RESTORATIVE MATERIALS; MECHANICAL-PROPERTIES; BASE; CAD/CAM;
D O I
10.1111/jopr.13987
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To assess the flexural strength (FS), surface roughness, and color stability of additive manufactured (AM) and subtractive manufactured (SM) denture teeth materials, as well as the effect of thermocycling on these properties. Materials and Methods: Eighty strips (20/material type; 64x10x3.3 mm) and 60 discs (15/material type; 12x4 mm) were fabricated from four different denture teeth materials (Straumann, Flexcera, Ivoclar, and Candulor). The specimens were divided into two subgroups (nonthermal cycled and 5000 thermal cycled,10 per subgroup), and subjected to a 3-point test for FS using a universal testing machine at a crosshead speed of 5.0 mm/min. Surface roughness (R-a, mu m) and color differences (Delta E-00) of disc specimens were measured before and after thermocycling using a noncontact optical profilometer and a spectrophotometer, respectively. The CIEDE2000 formula was used to calculate the color differences (Delta E-00) before and after thermocycling. Data were analyzed using 2-way ANOVA followed by post hoc multiple comparison tests (alpha = 0.05). Results: There was no significant difference in flexural strength between nonthermal cycled SM materials (p = 0.15), which were significantly higher than AM materials (p < 0.001). The flexural strength values of all tested materials were significantly reduced after thermocycling (p < 0.05). The material type had a significant effect on the R-a values (p < 0.001), whereas thermocycling did not (p = 0.81). After thermocycling, all materials exhibited color changes lower than the clinical perceptible threshold (Delta E-00 = 2.7). Conclusions: Thermocycling decreased the FS of denture teeth materials manufactured with AM and SM, but did not affect the surface roughness. The FS values of SM groups were significantly higher than AM materials, irrespective of thermocycling. No clinically significant color changes of the denture teeth material were noted.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Effect of Simulated Gastric Acid on Aesthetical Restorative CAD-CAM Materials' Microhardness and Flexural Strength
    Gulakar, T. L.
    Comert, G. N.
    Karaman, E.
    Cakan, U.
    Ozel, G. S.
    Ahmet, S. O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (10) : 1505 - 1511
  • [22] CAD-CAM complete denture resins: an evaluation of biocompatibility, mechanical properties, and surface characteristics
    Srinivasan, Murali
    Kalberer, Nicole
    Kamnoedboon, Porawit
    Mekki, Mustapha
    Durual, Stephane
    Oezcan, Mutlu
    Mueller, Frauke
    JOURNAL OF DENTISTRY, 2021, 114
  • [23] Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials
    Atalay, Sevda
    Cakmak, Gulce
    Fonseca, Manrique
    Schimmel, Martin
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05) : 787 - 795
  • [24] Repair Bond Strength and Surface Roughness Evaluation of CAD/CAM Materials After Various Surface Pretreatments
    Dikici, Burcu
    Basaran, Elif Turkes
    Sirinsukan, Nazli
    Can, Esra
    COATINGS, 2025, 15 (04):
  • [25] Effect of storage and aging conditions on the flexural strength and flexural modulus of CAD/CAM materials
    Porto, Thiago Soares
    Roperto, Renato Cassio
    Akkus, Anna
    Akkus, Ozan
    Teich, Sorin
    Faddoul, Fady
    Porto-neto, Sizenando Toledo
    Campos, Edson Alves
    DENTAL MATERIALS JOURNAL, 2019, 38 (02) : 264 - 270
  • [26] Effect of various surface treatments on the bond strength of resin luting agent and the surface roughness and surface energy of CAD/CAM materials
    Chuenjit, Pakorn
    Suzuki, Masaya
    Shinkai, Koichi
    DENTAL MATERIALS JOURNAL, 2021, 40 (01) : 16 - 25
  • [27] Color stability of CAD-CAM hybrid ceramic materials following immersion in artificial saliva and wine
    Nagai, Toshiki
    Alfaraj, Amal
    Chu, Tien-Min G.
    Yang, Chao-Chieh
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [28] Effect of artificial toothbrushing and water storage on the surface roughness and micromechanical properties of tooth-colored CAD-CAM materials
    Flury, Simon
    Diebold, Elisabeth
    Peutzfeldt, Anne
    Lussi, Adrian
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (06) : 767 - 774
  • [29] The Effects of Salivary pH on Color Stability and Surface Roughness of Different Denture Acrylic Resin Materials
    Alfadda, Sara A.
    Al-Otaibi, Hanan N.
    Al Shaalan, Nouf S.
    Al Qarni, Roba
    AlMutairi, Ree M.
    Al Taweel, Sara M.
    AlFouzan, Afnan
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (03): : 1287 - 1294
  • [30] Are Dental Prophylaxis Protocols Safe for CAD-CAM Restorative Materials? Surface Characteristics and Fatigue Strength
    da Rosa, Lucas Saldanha
    Souza, Luiza Freitas Brum
    Pilecco, Rafaela Oliveira
    Kluch, Thais Andressa Cavalcante
    Binotto, Felipe Somavilla
    Henriques, Vitoria Zanetti
    Kleverlaan, Cornelis Johannes
    Pereira, Gabriel Kalil Rocha
    Tribst, Joao Paulo Mendes
    COATINGS, 2024, 14 (12):