The effect of intraoperative fluoroscopy on acetabular component positioning and patient anatomy restoration during total hip arthroplasty: A systematic review and meta-analysis

被引:1
作者
Sun, Changjiao [1 ]
Gao, Hong [2 ]
Ma, Qi [1 ]
Li, Huimin [3 ]
Zhang, Xiaofei [4 ]
Cai, Xu [1 ]
机构
[1] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Orthoped Sports Med Ctr, Beijing 102218, Peoples R China
[2] Beijing MEDERA Med Grp, Beijing, Peoples R China
[3] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Nurse, Beijing, Peoples R China
[4] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Clin Epidemiol & Biostat, Beijing, Peoples R China
关键词
dislocation; intraoperative fluoroscopy; limb length difference; safe zone; total hip arthroplasty; LIMB LENGTH; POSTERIOR;
D O I
10.1097/MD.0000000000039528
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:In total hip arthroplasty (THA), the positioning of components holds critical importance for factors such as joint stability, polyethylene liner wear, and range of motion. This meta-analysis aimed to compare the effects of intraoperative fluoroscopy (IF) versus no use of IF on component positioning and the restoration of patient anatomy during THA. Methods:We conducted our systematic review following the recommendations outlined in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. The literature search was performed from the inception of medical databases up to August 2023. PubMed, Embase, Web of Science, Cochrane Controlled Trials Register, Cochrane Library, Highwire, Wanfang, China National Knowledge Infrastructure (CNKI), China Biology Medicine Disc (CBM), and China Science and Technology Journal (CSTD) databases were systematically searched to identify relevant studies comparing IF versus no IF during primary THA. Results:Thirteen studies involving 2195 patients (2207 hips) were incorporated in the Analysis. No statistically significant differences were observed between the groups in terms of acetabular cup inclination angle (ACIA, P = .9), ACIA within the safe zone rate (P = .87), acetabular cup anteversion angle (ACAA, P = .42), ACAA within the safe zone rate (P = .35), combined safe zone rate (P = .30), limb length difference (LLD, P = .13), dislocation rate (P = .76), and infection rate (P = .97). In comparison to the no fluoroscopy group, the IF group exhibited prolonged operation time (P < .00001) and reduced femoral component offset difference (FCOD, P = .03). Conclusion:IF did not demonstrate improvements in acetabular cup placement, limb length difference, or dislocation occurrence. Nonetheless, IF showed a significant enhancement in restoring femoral offset. It is noteworthy that surgeons operating in facilities with lower patient volumes may observe more pronounced benefits from IF.
引用
收藏
页数:10
相关论文
共 46 条
[1]   What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position [J].
Abdel, Matthew P. ;
von Roth, Philipp ;
Jennings, Matthew T. ;
Hanssen, Arlen D. ;
Pagnano, Mark W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) :386-391
[2]   Utility of Intraoperative Fluoroscopic Positioning of Total Hip Arthroplasty Components Using a Posterior and Direct Anterior Approach [J].
Belyea, Christopher M. ;
Lansford, Jefferson L. ;
Yim, Duke G. .
MILITARY MEDICINE, 2022, 187 (1-2) :E11-E16
[3]   Does Intraoperative Fluoroscopy Improve Limb-Length Discrepancy and Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty? [J].
Bingham, Joshua S. ;
Spangehl, Mark J. ;
Hines, Jeremy T. ;
Taunton, Michael J. ;
Schwartz, Adam J. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (09) :2927-2931
[4]  
Brown Nicholas M, 2021, Hip Pelvis, V33, P128, DOI [10.5371/hp.2021.33.3.128, 10.5371/hp.2021.33.3.128]
[5]  
Chen Qin, 2006, Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi, V20, P1172
[6]   The efficacy of patient specific instrumentation (PSI) in total hip arthroplasty (THA): A systematic review and meta-analysis [J].
Constantinescu, David S. ;
Costello II, Joseph P. ;
Dalling, Anil D. ;
Wagner, Jaxon D. ;
Al-Hardan, Waleed ;
Carvajal, Jaime A. .
JOURNAL OF ORTHOPAEDICS, 2022, 34 :404-413
[7]   Strengthening systematic reviews in public health: guidance in the Cochrane Handbook for Systematic Reviews of Interventions, 2nd edition [J].
Cumpston, Miranda S. ;
McKenzie, Joanne E. ;
Welch, Vivian A. ;
Brennan, Sue E. .
JOURNAL OF PUBLIC HEALTH, 2022, 44 (04) :E588-E592
[8]   Occupational Hazards to the Joint Replacement Surgeon: Radiation Exposure [J].
Daryoush, Joshua R. ;
Lancaster, Alex J. ;
Frandsen, Jeffrey J. ;
Gililland, Jeremy M. .
JOURNAL OF ARTHROPLASTY, 2022, 37 (08) :1464-1469
[9]   Total Knee Arthroplasty in Hemophilia: Survivorship and OutcomesdA Systematic Review and Meta-Analysis [J].
Fenelon, Christopher ;
Murphy, Evelyn P. ;
Fahey, Eoin J. ;
Murphy, Robert P. ;
O'Connell, Niamh M. ;
Queally, Joseph M. .
JOURNAL OF ARTHROPLASTY, 2022, 37 (03) :581-+
[10]   Lower limb length and offset in total hip arthroplasty [J].
Flecher, X. ;
Ollivier, M. ;
Argenson, J. N. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) :S9-S20