A MODIFIED CONTROL SCHEME TO MITIGATE HARMONICS, IMPROVE VOLTAGE REGULATION & POWER FACTOR USING SINGLE-PHASE SHUNT ACTIVE POWER FILTER

被引:0
作者
Samanta, Jotirmoy [1 ]
Sangno, Ralli [1 ]
Pudur, Rajen [1 ]
机构
[1] NIT Arunachal Pradesh, Dept Elect Engn, Jote, India
来源
SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY | 2024年 / 31卷 / 05期
关键词
Harmonics reduction; Power factor improvement; Power quality; Shunt Active Power Filter; DESIGN;
D O I
10.55766/sujst-2024-06-e03764
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents a modified control scheme to eliminate various power quality issues using a singlephase shunt active power filter (SAPF). The focus is primarily on harmonics mitigation, power factor (PF) correction, DC link voltage regulation, and reducing the settling time of the system. A nonlinear PID (NLPID) controller is employed to regulate the DC link voltage and reduce the system's settling time. The overall system is modeled for a 1 kW load and tested under 85% load condition. The results, obtained using the MATLAB/Simulink platform, are found to be quite satisfactory. After compensation, the total harmonic distortion (THD) is reduced to below 8%, in compliance with the IEEE 519-2022 standard, and the PF is improved to nearly unity.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 28 条
[1]   Proportional-integral/proportional-integral-derivative tuning procedure of a single-phase shunt active power filter using Bode diagram [J].
Angelico, Bruno A. ;
Campanhol, Leonardo B. G. ;
Oliveira da Silva, Sergio A. .
IET POWER ELECTRONICS, 2014, 7 (10) :2647-2659
[2]   A Lyapunov-Function Based Controller for 3-Phase Shunt Active Power Filter and Performance Assessment Considering Different System Scenarios [J].
Bajaj, Mohit ;
Flah, Aymen ;
Alowaidi, Majed ;
Sharma, Naveen Kumar ;
Mishra, Shailendra ;
Sharma, Sunil Kumar .
IEEE ACCESS, 2021, 9 :66079-66102
[3]   Improved harmonic suppression efficiency of single-phase APFs in distorted distribution systems [J].
Biricik, Samet ;
Redif, Soydan ;
Khadem, Shafiuzzaman K. ;
Basu, Malabika .
INTERNATIONAL JOURNAL OF ELECTRONICS, 2016, 103 (02) :232-246
[4]   An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads [J].
Chandra, A ;
Singh, B ;
Singh, BN ;
Al-Haddad, K .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :495-507
[5]   A Prospective on Voltage Regulation of Self-Excited Induction Generators for Industry Applications [J].
Chauhan, Yogesh K. ;
Jain, Sanjay K. ;
Singh, Bhim .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (02) :720-730
[6]  
CIVIDINO L, 1992, INTELEC - FOURTEENTH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, P506
[7]   Synergetic control for three-level voltage source inverter-based shunt active power filter to improve power quality [J].
Deffaf, Brahim ;
Farid, Hamoudi ;
Benbouhenni, Habib ;
Medjmadj, Slimane ;
Debdouche, Naamane .
ENERGY REPORTS, 2023, 10 :1013-1027
[8]   Novel Neural Network Fractional-Order Sliding-Mode Control With Application to Active Power Filter [J].
Fei, Juntao ;
Wang, Huan ;
Fang, Yunmei .
IEEE TRANSACTIONS ON SYSTEMS MAN CYBERNETICS-SYSTEMS, 2022, 52 (06) :3508-3518
[9]  
Gautam S., 2014, International Journal of Power Electronics and Drive Systems, V4, P112, DOI [10.11591/ijpeds.v4i1.4723, DOI 10.11591/IJPEDS.V4I1.4723]
[10]  
Grady W.M., 1993, P EPIR POW QUAL ISS, P1