On-site electro-generation of H2O2 combined with UV process: Multiple pharmaceutically active compounds degradation for drinking water systems

被引:0
作者
Guimaraes, Raissa Engroff [1 ,3 ]
Albornoz, Louidi Lauer [1 ]
Beltrame, Thiago Favarini [2 ]
Gabaldon, Montserrat Garcia [3 ]
Borba, Fernando Henrique [2 ]
da Silva, Salatiel Wohlmuth [1 ]
机构
[1] Fed Univ Rio Grande Do Sul UFRGS, Inst Hydraul Res IPH, Postgrad Program Water Resources & Environm Sanita, Ave Bento Goncalves,9500, BR-91509900 Porto Alegre, RS, Brazil
[2] Fed Univ Fronteira Sul, Postgrad Environm & Sustainable Technol Program, Ave Jacob Reinaldo Haupenthal,1580, BR-97900000 Cerro Largo, RS, Brazil
[3] Univ Politecn Valencia, IEC Grp, ISIRYM, Cami Vera S-N, Valencia, Spain
关键词
E-H; 2; O; /UV-C; Solid electrolyte; Ion exchange membrane; Pharmaceutical contaminants; Advanced water treatment; ADVANCED OXIDATION PROCESSES; ELECTROCHEMICAL ADVANCED OXIDATION; GAS-DIFFUSION ELECTRODES; HYDROGEN-PEROXIDE; WASTE-WATER; EMERGING CONTAMINANTS; SULFAMETHOXAZOLE; REMOVAL; UV/H2O2; PRODUCTS;
D O I
10.1016/j.seppur.2025.131608
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Atenolol (ATN), prednisone (PRED), and sulfamethoxazole (SMX) are widely used pharmaceuticals that persist in aquatic environments, posing risks to non-target organisms due to potential synergistic toxicity. This study investigates the degradation of these contaminants using electrochemical H2O2 generation (E-H2O2), alone and combined with UV-C irradiation, focusing on advancing water treatment technologies. The system employed an electrochemical reactor with a gas diffusion electrode (GDE) as the cathode and a cation exchange membrane to prevent H2O2 oxidation at the anode. A solid electrolyte was used for proton conduction to enhance practicality and reduce chemical inputs, and ionic adsorption capabilities were demonstrated, promoting electrostatic interactions with PhACs. At an optimized current density of 30 mA cm-2, contaminant degradation was evaluated across UV-C, E-H2O2, and the combined E-H2O2/UV-C system. The E-H2O2/UV-C process achieved the highest degradation efficiency within 15 min, breaking contaminants into simpler carboxylic acids and showing no phytotoxicity in Allium cepa bioassays. However, GDE characterization revealed morphological changes and catalyst loss after extended use, potentially impacting H2O2 generation stability and efficiency. These findings suggest that the E-H2O2/UV-C system holds potential for water treatment applications targeting multicontaminant degradation. Future studies should focus on developing more durable cathode materials to ensure sustained performance under prolonged operational conditions.
引用
收藏
页数:14
相关论文
共 105 条
[1]   Comparative study of hydrogen peroxide electro-generation on gas-diffusion electrodes in undivided and membrane cells [J].
Agladze, G. R. ;
Tsurtsumia, G. S. ;
Jung, B. -I. ;
Kim, J. -S. ;
Gorelishvili, G. .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2007, 37 (03) :375-383
[2]   Detoxification and degradation of sulfamethoxazole by soybean peroxidase and UV + H2O2 remediation approaches [J].
Al-Maqdi, Khadega A. ;
Hisaindee, Soleiman ;
Rauf, Muhammad A. ;
Ashraf, S. Salman .
CHEMICAL ENGINEERING JOURNAL, 2018, 352 :450-458
[3]   Photolysis and UV/H2O2 of diclofenac, sulfamethoxazole, carbamazepine, and trimethoprim: Identification of their major degradation products by ESI-LC-MS and assessment of the toxicity of reaction mixtures [J].
Alharbi, Sultan K. ;
Kang, Jinguo ;
Nghiem, Long D. ;
van de Merwe, Jason P. ;
Leusch, Frederic D. L. ;
Price, William E. .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2017, 112 :222-234
[4]   Revealing Decay Mechanisms of H2O2-Based Electrochemical Advanced Oxidation Processes after Long-Term Operation for Phenol Degradation [J].
An, Jingkun ;
Li, Nan ;
Wu, Yu ;
Wang, Shu ;
Liao, Chengmei ;
Zhao, Qian ;
Zhou, Lean ;
Li, Tian ;
Wang, Xin ;
Feng, Yujie .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (17) :10916-10925
[5]   Highly efficient electro-generation of H2O2 by adjusting liquid-gas solid three phase interfaces of porous carbonaceous cathode during oxygen reduction reaction [J].
An, Jingkun ;
Li, Nan ;
Zhao, Qian ;
Qiao, Yujie ;
Wang, Shu ;
Liao, Chengmei ;
Zhou, Lean ;
Li, Tian ;
Wang, Xin ;
Feng, Yujie .
WATER RESEARCH, 2019, 164
[6]  
ANVISA, 2020, Anuario Estatistico do Mercado Farmaceutico 2019/20
[7]   Phytotoxicity and genotoxicity evaluation of 2,4,6-tribromophenol solution treated by UV-based oxidation processes [J].
Arenhart Heberle, Alan Nelson ;
Pereira Alves, Maria Eduarda ;
da Silva, Salatiel Wohlmuth ;
Klauck, Claudia Regina ;
Siqueira Rodrigues, Marco Antonio ;
Bernardes, Andrea Moura .
ENVIRONMENTAL POLLUTION, 2019, 249 :354-361
[8]   In Situ Electrochemical Generation of Hydrogen Peroxide in Alkaline Aqueous Solution by using an Unmodified Gas Diffusion Electrode [J].
Barros, Willyam R. P. ;
Ereno, Thais ;
Tavares, Ana C. ;
Lanza, Marcos R. V. .
CHEMELECTROCHEM, 2015, 2 (05) :714-719
[9]   Removal of charged micropollutants from water by ion-exchange polymers - Effects of competing electrolytes [J].
Bauerlein, Patrick S. ;
ter Laak, Thomas L. ;
Hofman-Caris, Roberta C. H. M. ;
de Voogt, Pim ;
Droge, Steven T. J. .
WATER RESEARCH, 2012, 46 (16) :5009-5018
[10]   Investigation of pharmaceuticals and their metabolites in Brazilian hospital wastewater by LC-QTOF MS screening combined with a preliminary exposure and in silico risk assessment [J].
Becker, Raquel Wielens ;
Ibanez, Maria ;
Lumbaque, Elisabeth Cuervo ;
Wilde, Marcelo Luis ;
da Rosa, Taina Flores ;
Hernandez, Felix ;
Sirtori, Carla .
SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 699