Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners

被引:0
|
作者
Dole, Andrew [1 ,2 ]
Sims, Stacy [3 ,4 ]
Gan, Han [5 ]
Gill, Nic [1 ]
Beaven, Martyn [1 ]
机构
[1] Univ Waikato, Te Huataki Waiora Sch Hlth, Div Hlth Engn Comp & Sci, Tauranga, New Zealand
[2] Adams Ctr High Performance, Mt Maunganui, Mount Maunganui, New Zealand
[3] Auckland Univ Technol, Sports Performance Res Inst New Zealand SPRINZ, Auckland, New Zealand
[4] Stanford Univ, Stanford Lifestyle Med, Palo Alto, CA USA
[5] Univ Waikato, Dept Math, Hamilton, New Zealand
关键词
metabolism; menstrual cycle; continuous glucose monitoring; female athlete; interstitial; MENSTRUAL-CYCLE; EXERCISE; PROGESTERONE; METABOLISM; WOMEN;
D O I
10.1123/ijspp.2024-0068
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: Continuous-glucose-monitoring (CGM) sensors provide near-real-time glucose data and have been introduced commercially as a tool to inform nutrition decisions. The aim of this pilot study was to explore how factors such as the menstrual phase, extended running duration, and carbohydrates affect CGM outcomes among trained eumenorrheic females in an outdoor simulated ultraendurance running event. Methods: Twelve experienced female ultrarunners (age 39 [6] y) participated in this crossover study. Participants completed an ultraendurance simulation run of 4 hours in the midfollicular and midluteal phases of their menstrual cycle, which consisted of a 3-hour fasted outdoor run (FASTED) followed by a 1-hour treadmill run (TREAD), where 3 standardized 20-g oral glucose doses were provided. Results: Using a mixed linear model, the menstrual phase was statistically significant for differences in glucose measurements from CGM compared with capillary glucose sampling during TREAD (P = .02) but not FASTED. Additionally, the CGM sensor reported glucose levels with an average of -0.43 mmol<middle dot>L-1 (95% CI, - 0.86 to -0.005) and -1.02 mmol<middle dot>L-1 (95% CI, -1.63 to -0.42) lower in fasted and fed scenarios, respectively, when compared with capillary glucose. Conclusion: CGM underreports capillary glucose during fasted and fed exercise. Factors contributing to this underreporting between the sampling methods (CGM vs capillary) were dependent on a combination of exogenous glucose availability, individual biological differences, and the menstrual phase.
引用
收藏
页码:265 / 274
页数:10
相关论文
共 50 条
  • [21] Hypoglycemia in blood glucose level in type 2 diabetic Japanese patients by continuous glucose monitoring
    Hajime, Maiko
    Okada, Yosuke
    Mori, Hiroko
    Uemura, Fumi
    Sonoda, Satomi
    Tanaka, Kenichi
    Kurozumi, Akira
    Narisawa, Manabu
    Torimoto, Keiichi
    Tanaka, Yoshiya
    DIABETOLOGY & METABOLIC SYNDROME, 2019, 11 (1)
  • [22] Effect of Arterialization on Venous Blood Glucose Concentrations and Implications for Observed Continuous Glucose Monitoring Accuracy
    Pleus, Stefan
    Link, Manuela
    Hinzmann, Rolf
    Oeter, Sukrue
    Eichenlaub, Manuel
    Baumstark, Annette
    Haug, Cornelia
    Freckmann, Guido
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (04) : 238 - 245
  • [23] Colecole model for glucose-dependent dielectric properties of blood plasma for continuous glucose monitoring
    Karacolak, Tutku
    Moreland, Elaine C.
    Topsakal, Erdem
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2013, 55 (05) : 1160 - 1164
  • [24] Hypoglycemia in blood glucose level in type 2 diabetic Japanese patients by continuous glucose monitoring
    Maiko Hajime
    Yosuke Okada
    Hiroko Mori
    Fumi Uemura
    Satomi Sonoda
    Kenichi Tanaka
    Akira Kurozumi
    Manabu Narisawa
    Keiichi Torimoto
    Yoshiya Tanaka
    Diabetology & Metabolic Syndrome, 11
  • [25] Continuous blood glucose monitoring reduces the risk to ICU patients
    KP Mulavisala
    J Norrie
    B Crane
    N Barwell
    Critical Care, 19 (Suppl 1):
  • [26] The Optimal Duration of a Run-In Period to Initiate Continuous Glucose Monitoring for a Randomized Trial
    Raghinaru, Dan
    Calhoun, Peter
    Bergenstal, Richard M. M.
    Beck, Roy W. W.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (12) : 868 - 872
  • [27] Usefulness of continuous glucose monitoring of blood glucose control in patients with diabetes undergoing hemodialysis: A pilot study
    Lee, Sua
    Lee, Soyoung
    Kim, Kyeong Min
    Shin, Jong Ho
    FRONTIERS IN MEDICINE, 2023, 10
  • [28] Continuous Glucose Monitoring vs. Capillary Blood Glucose in Hospitalized Type 2 Diabetes Patients
    Verissimo, David
    Vinhais, Joana
    Ivo, Catarina
    Martins, Ana Claudia
    Nunes e Silva, Joao
    Passos, Dolores
    Castro, Joao Jacome
    Lopes, Luis
    Marcelino, Mafalda
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [29] Safety of a continuous glucose monitoring device during hyperbaric exposure
    Bliss, Chae
    Huang, Enoch
    Savaser, Davut
    UNDERSEA AND HYPERBARIC MEDICINE, 2020, 47 (01) : 13 - 19
  • [30] Accuracy of continuous glucose monitoring during differing exercise conditions
    Bally, Lia
    Zueger, Thomas
    Pasi, Nicola
    Carlos, Ciller
    Paganini, Daniela
    Stettler, Christoph
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 112 : 1 - 5