Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners

被引:0
|
作者
Dole, Andrew [1 ,2 ]
Sims, Stacy [3 ,4 ]
Gan, Han [5 ]
Gill, Nic [1 ]
Beaven, Martyn [1 ]
机构
[1] Univ Waikato, Te Huataki Waiora Sch Hlth, Div Hlth Engn Comp & Sci, Tauranga, New Zealand
[2] Adams Ctr High Performance, Mt Maunganui, Mount Maunganui, New Zealand
[3] Auckland Univ Technol, Sports Performance Res Inst New Zealand SPRINZ, Auckland, New Zealand
[4] Stanford Univ, Stanford Lifestyle Med, Palo Alto, CA USA
[5] Univ Waikato, Dept Math, Hamilton, New Zealand
关键词
metabolism; menstrual cycle; continuous glucose monitoring; female athlete; interstitial; MENSTRUAL-CYCLE; EXERCISE; PROGESTERONE; METABOLISM; WOMEN;
D O I
10.1123/ijspp.2024-0068
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: Continuous-glucose-monitoring (CGM) sensors provide near-real-time glucose data and have been introduced commercially as a tool to inform nutrition decisions. The aim of this pilot study was to explore how factors such as the menstrual phase, extended running duration, and carbohydrates affect CGM outcomes among trained eumenorrheic females in an outdoor simulated ultraendurance running event. Methods: Twelve experienced female ultrarunners (age 39 [6] y) participated in this crossover study. Participants completed an ultraendurance simulation run of 4 hours in the midfollicular and midluteal phases of their menstrual cycle, which consisted of a 3-hour fasted outdoor run (FASTED) followed by a 1-hour treadmill run (TREAD), where 3 standardized 20-g oral glucose doses were provided. Results: Using a mixed linear model, the menstrual phase was statistically significant for differences in glucose measurements from CGM compared with capillary glucose sampling during TREAD (P = .02) but not FASTED. Additionally, the CGM sensor reported glucose levels with an average of -0.43 mmol<middle dot>L-1 (95% CI, - 0.86 to -0.005) and -1.02 mmol<middle dot>L-1 (95% CI, -1.63 to -0.42) lower in fasted and fed scenarios, respectively, when compared with capillary glucose. Conclusion: CGM underreports capillary glucose during fasted and fed exercise. Factors contributing to this underreporting between the sampling methods (CGM vs capillary) were dependent on a combination of exogenous glucose availability, individual biological differences, and the menstrual phase.
引用
收藏
页码:265 / 274
页数:10
相关论文
共 50 条
  • [1] Continuous monitoring of blood glucose
    Robert, JJ
    HORMONE RESEARCH, 2002, 57 : 81 - 84
  • [2] Continuous glucose monitoring in diabetic long distance runners
    Cauza, E
    Hanusch-Enserer, U
    Strasser, B
    Ludvik, B
    Kostner, K
    Dunky, A
    Haber, P
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (09) : 774 - 780
  • [3] Hyperglycemia during hepatic resection: continuous monitoring of blood glucose concentration
    Maeda, Hiromichi
    Okabayashi, Takehiro
    Nishimori, Isao
    Yamashita, Koichi
    Sugimoto, Takeki
    Hanazaki, Kazuhiro
    AMERICAN JOURNAL OF SURGERY, 2010, 199 (01) : 8 - 13
  • [4] Continuous Glucose Monitoring During Pregnancy
    Chitayat, Lironn
    Zisser, Howard
    Jovanovic, Lois
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S105 - S111
  • [5] Continuous Glucose Monitoring-Measured Glucose Levels During Oral Glucose Tolerance Testing in Pregnancy
    Carlson, Anders L.
    Beck, Roy W.
    Li, Zoey
    Norton, Elizabeth
    Bergenstal, Richard M.
    Johnson, Mary
    Dunnigan, Sean
    Banfield, Matthew
    Krumwiede, Katie
    Sibayan, Judy
    Calhoun, Peter
    Durnwald, Celeste
    DIABETES TECHNOLOGY & THERAPEUTICS, 2025,
  • [6] The Efficacy and Effectiveness of Continuous Glucose Monitoring During Pregnancy: A Systematic Review
    Voormolen, Daphne N.
    DeVries, J. Hans
    Evers, Inge M.
    Mol, Ben W. J.
    Franx, Arie
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2013, 68 (11) : 753 - 763
  • [7] Dynamics of glucose concentration during the initiation of ketogenic diet treatment in children with refractory epilepsy: Results of continuous glucose monitoring
    Brozova, Klara
    Michalec, Juraj
    Brabec, Marek
    Borilova, Petra
    Kohout, Pavel
    Broz, Jan
    EPILEPSIA OPEN, 2023, 8 (03) : 1021 - 1027
  • [8] The value of Continuous Glucose Monitoring and Self-Monitoring of Blood Glucose in patients with Gestational Diabetes Mellitus during Ramadan fasting
    Afandi, Bachar
    Hassanein, Mohamed
    Roubi, Sana
    Nagelkerke, Nico
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 151 : 260 - 264
  • [9] Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring
    Kusunoki, Yoshiki
    Katsuno, Tomoyuki
    Nakae, Rie
    Watanabe, Kahori
    Akagami, Takafumi
    Ochi, Fumihiro
    Tokuda, Masaru
    Murai, Kazuki
    Miuchi, Masayuki
    Miyagawa, Jun-ichiro
    Namba, Mitsuyoshi
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (02) : 342 - 349
  • [10] Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose to Assess Glycemia in Gestational Diabetes
    Zaharieva, Dessi P.
    Teng, Jessie H.
    Ong, May Lea
    Lee, Melissa H.
    Paldus, Barbora
    Jackson, Linda
    Houlihan, Christine
    Shub, Alexis
    Tipnis, Sheetal
    Cohen, Ohad
    O'Neal, David N.
    Krishnamurthy, Balasubramanian
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (11) : 822 - 827