Population-specific femur models: A step towards improved osteosynthetic biomechanical testing in orthopaedics

被引:3
作者
Hollensteiner, Marianne [1 ,2 ]
Baumeister, Dirk [1 ,2 ]
Muehling, Mischa [1 ,2 ]
Greinwald, Markus [1 ,2 ]
Sandriesser, Sabrina [1 ,2 ]
Hofstaetter, Bernhard [3 ]
Petersik, Andreas [3 ]
Augat, Peter [1 ,2 ]
机构
[1] BG Unfallklin Murnau, Inst Biomech, Prof Kuntscher Str 8, D-82418 Murnau, Germany
[2] Paracelsus Med Univ Salzburg, Inst Biomech, Strubergasse 21, A-5020 Salzburg, Austria
[3] Stryker Trauma GmbH, T&E Simulat, Prof Kuntscher Str 1-5, D-24232 Schonkirchen, Germany
基金
奥地利科学基金会;
关键词
Synthetic bone; Biomechanics; Bone model; Surrogate; Population variability; STRUCTURAL-PROPERTIES; MECHANICAL-PROPERTIES; FRACTURE FIXATION; COMPOSITE FEMURS; BONE-DENSITY;
D O I
10.1016/j.clinbiomech.2024.106379
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Biomechanical testing using synthetic bone surrogates has become a standard method for evaluating osteosynthesis techniques. However, these surrogates often fail to account for population-specific variations in bone anatomy and mechanical properties, leading to limitations in predicting clinical outcomes. This study addresses this gap by developing and validating a population-specific synthetic femur model for older women of European ethnicity, incorporating variations in geometry and mechanics observed in this demographic. Methods: The femur model was developed using a statistical shaping algorithm and 3D models from women aged 75 to 85 years. Synthetic femora were fabricated using polyurethane, enriched with fillers and additives to mimic osteoporotic bone characteristics. Mechanical testing, including axial compression, four-point bending, and torsion, was performed on synthetic femora and were validated against human osteoporotic femora. Findings: The synthetic femora demonstrated comparable mechanical properties to human osteoporotic femora, particularly in flexural and torsional rigidity. Axial stiffness was slightly lower in the synthetic femora but remained within the range of literature values. Statistical analysis revealed significant differences between synthetic and human bones in certain parameters, highlighting the need for population-specific models. Interpretation: The developed synthetic femur model offers a promising solution for addressing the limitations of current bone surrogates in biomechanical testing. By incorporating population-specific characteristics these models provide a more accurate representation of human bone, improving the validity of biomechanical evaluations and potentially leading to more equitable treatment outcomes in orthopaedics. Further research is warranted to explore the applicability of these models across different populations and anatomical sites.
引用
收藏
页数:7
相关论文
共 41 条
[1]   Osteoporotic fracture fixation - a biomechanical perspective [J].
Augat, Peter ;
Goldhahn, Jorg .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 :S1-S2
[2]   Biomechanical measurements of cortical screw purchase in five types of human and artificial humeri [J].
Aziz, Mina S. R. ;
Nicayenzi, Bruce ;
Crookshank, Meghan C. ;
Bougherara, Habiba ;
Schemitsch, Emil H. ;
Zdero, Radovan .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 30 :159-167
[3]   A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures [J].
Basso, Trude ;
Klaksvik, Jomar ;
Syversen, Unni ;
Foss, Olav A. .
JOURNAL OF BIOMECHANICS, 2014, 47 (16) :3898-3902
[4]   Biomechanical Comparison of Cadaveric and Commercially Available Synthetic Osteoporotic Bone Analogues in a Locked Plate Fracture Model Under Torsional Loading [J].
Becker, Edward H. ;
Kim, Hyunchul ;
Shorofsky, Michael ;
Hsieh, Adam H. ;
Watson, Jeffrey D. ;
O'Toole, Robert V. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (05) :E136-E141
[5]   Mechanical validation of whole bone composite tibia models [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :279-288
[6]   Cortical bone continuum damage mechanics constitutive model with stress triaxiality criterion to predict fracture initiation and pattern [J].
Cronin, D. S. ;
Watson, B. ;
Khor, F. ;
Gierczycka, D. ;
Malcolm, S. .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
[7]   Composite Bone Models in Orthopaedic Surgery Research and Education [J].
Elfar, John J. ;
Menorca, Ron Martin Garcia ;
Reed, Jeffrey Douglas ;
Stanbury, Spencer .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2014, 22 (02) :111-120
[8]   Biomechanical Testing of Fracture Fixation Constructs: Variability, Validity, and Clinical Applicability [J].
Gardner, Michael J. ;
Silva, Matthew J. ;
Krieg, James C. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (02) :86-93
[9]   Evaluating the mechanical response of novel synthetic femurs for representing osteoporotic bone [J].
Gluek, Cooper ;
Zdero, Radovan ;
Quenneville, Cheryl E. .
JOURNAL OF BIOMECHANICS, 2020, 111
[10]   Artificial composite bone as a model of human trabecular bone:: The implant-bone interface [J].
Grant, J. A. ;
Bishop, N. E. ;
Goetzen, N. ;
Sprecher, C. ;
Honl, M. ;
Morlock, M. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (05) :1158-1164