Electrochemiluminescence ratio sensor for detecting MCP-1 based on s-PdNS

被引:1
作者
Mao, Weiran [1 ]
Zhang, Xiaoyan [2 ]
Yin, Yuanyuan [1 ]
Tang, Xiaohua [1 ]
Jiang, Qingqing [1 ]
Chen, Xia [1 ]
Chen, Xiaoliang [2 ]
机构
[1] Chongqing Univ, Canc Hosp, Chongqing Key Lab Translat Res Canc Metastasis & I, 181 Hanyu Rd, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Canc Hosp, Dept Nucl Med, 181 Hanyu Rd, Chongqing 400030, Peoples R China
关键词
Immunosensor; Monocyte chemoattractant protein-1; Sulfur-doped palladium nanosheets; ECL-RET; MONOCYTE CHEMOATTRACTANT PROTEIN-1; RESONANCE ENERGY-TRANSFER; EXPRESSION; ATHEROSCLEROSIS; IMMUNOSENSOR; CELLS;
D O I
10.1016/j.sbsr.2024.100723
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study proposes a novel sandwich-based ratio electrochemiluminescence (ECL) immunosensor for detecting monocyte chemotactic protein-1 (MCP-1), a marker of cardiovascular disease. We synthesized sulfur-doped palladium nanosheets (S-PdNS), which possess a stable structure and uniform morphology, and can quench signals generated by the S2O82- /O2 ECL system. Using glutaraldehyde (GA), we conjugated luminol to these nanosheets and combined them with a secondary antibody. This modification enabled the nanomaterial to produce a new luminol signal as an internal reference for detection while quenching the S2O82- /O2 ECL signal. To date, no studies have utilized both mechanisms for detection. Furthermore, the deposition of gold nanoparticles (AuNPs) on the surface of the glassy carbon electrode (GCE) allowed for increased antibody binding and improved electron transmission in the ECL system. When trace analytes are present, the S2O82- /O2 ECL signal decreases, and the luminol ECL signal increases. This setup allowed us to obtain two signals from one measurement and use the ratio to construct a standard curve, significantly reducing the possibility of misjudgment. Under optimal conditions, the linear detection range for MCP-1 is 10-2.5 pg mL- 1 to 103 pg mL-1, with a detection limit of 1.6 fg mL- 1 (S / N = 3). The immunosensor also exhibited excellent selectivity, repeatability, and stability, expanding the application of the dual luminescence mechanism and providing an effective method for early monitoring of cardiovascular disease.
引用
收藏
页数:8
相关论文
共 25 条
[11]   Aggregation-Induced Emission in Electrochemiluminescence: Advances and Perspectives [J].
Moreno-Alcantar, Guillermo ;
Aliprandi, Alessandro ;
De Cola, Luisa .
TOPICS IN CURRENT CHEMISTRY, 2021, 379 (04)
[12]   Novel preparation and electrochemiluminescence application of luminol functional-Au nanoclusters for ALP determination [J].
Nie, Fei ;
Luo, Kai ;
Zheng, Xiaohui ;
Zheng, Jianbin ;
Song, Zhenghua .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 218 :152-159
[13]   Simultaneous elevation of the levels of circulating monocyte chemoattractant protein-1 and tissue factor in acute coronary syndromes [J].
Nishiyama, K ;
Ogawa, H ;
Yasue, H ;
Soejima, H ;
Misumi, K ;
Takazoe, K ;
Yoshimura, M ;
Kugiyama, K ;
Tsuji, I ;
Kumeda, K .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1998, 62 (09) :710-712
[14]   Plasma monocyte chemoattractant protein-1 antigen levels and the risk of restenosis after coronary stent implantation [J].
Oshima, S ;
Ogawa, H ;
Hokimoto, S ;
Nakamura, S ;
Noda, K ;
Saito, T ;
Soejima, H ;
Takazoe, K ;
Ishibashi, F ;
Yasue, H .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (04) :261-264
[15]  
PAINE R, 1993, J IMMUNOL, V150, P4561
[16]   The role of the chemokines MCP-1, GRO-α, IL-8 and their receptors in the adhesion of monocytic cells to human atherosclerotic plaques [J].
Papadopoulou, Charikleia ;
Corrigall, Valerie ;
Taylor, Peter R. ;
Poston, Robin N. .
CYTOKINE, 2008, 43 (02) :181-186
[17]   Advanced oxidation protein products induce monocyte chemoattractant protein-1 expression via p38 mitogen-activated protein kinase activation in rat vascular smooth muscle cells [J].
Peng Kan-Fu ;
Wu Xiong-Fei ;
Zhao Hong-Wen ;
Sun Yan .
CHINESE MEDICAL JOURNAL, 2006, 119 (13) :1088-1093
[18]   Estradiol suppresses MCP-1 expression in vivo - Implications for atherosclerosis [J].
Pervin, S ;
Singh, R ;
Rosenfeld, ME ;
Navab, M ;
Chaudhuri, G ;
Nathan, L .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1998, 18 (10) :1575-1582
[19]   New-Generation Low-Toxic I-III-VI2 Quantum Dots in Chemical Analysis [J].
Ponomaryova, T. S. ;
Novikova, A. S. ;
Abramova, A. M. ;
Goryacheva, O. A. ;
Drozd, D. D. ;
Strokin, P. D. ;
Goryacheva, I. Yu. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (04) :402-409
[20]   Trends and Advances in Electrochemiluminescence Nanobiosensors [J].
Rizwan, Mohammad ;
Mohd-Naim, Noor Faizah ;
Ahmed, Minhaz Uddin .
SENSORS, 2018, 18 (01)