Electrochemiluminescence ratio sensor for detecting MCP-1 based on s-PdNS

被引:1
作者
Mao, Weiran [1 ]
Zhang, Xiaoyan [2 ]
Yin, Yuanyuan [1 ]
Tang, Xiaohua [1 ]
Jiang, Qingqing [1 ]
Chen, Xia [1 ]
Chen, Xiaoliang [2 ]
机构
[1] Chongqing Univ, Canc Hosp, Chongqing Key Lab Translat Res Canc Metastasis & I, 181 Hanyu Rd, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Canc Hosp, Dept Nucl Med, 181 Hanyu Rd, Chongqing 400030, Peoples R China
关键词
Immunosensor; Monocyte chemoattractant protein-1; Sulfur-doped palladium nanosheets; ECL-RET; MONOCYTE CHEMOATTRACTANT PROTEIN-1; RESONANCE ENERGY-TRANSFER; EXPRESSION; ATHEROSCLEROSIS; IMMUNOSENSOR; CELLS;
D O I
10.1016/j.sbsr.2024.100723
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study proposes a novel sandwich-based ratio electrochemiluminescence (ECL) immunosensor for detecting monocyte chemotactic protein-1 (MCP-1), a marker of cardiovascular disease. We synthesized sulfur-doped palladium nanosheets (S-PdNS), which possess a stable structure and uniform morphology, and can quench signals generated by the S2O82- /O2 ECL system. Using glutaraldehyde (GA), we conjugated luminol to these nanosheets and combined them with a secondary antibody. This modification enabled the nanomaterial to produce a new luminol signal as an internal reference for detection while quenching the S2O82- /O2 ECL signal. To date, no studies have utilized both mechanisms for detection. Furthermore, the deposition of gold nanoparticles (AuNPs) on the surface of the glassy carbon electrode (GCE) allowed for increased antibody binding and improved electron transmission in the ECL system. When trace analytes are present, the S2O82- /O2 ECL signal decreases, and the luminol ECL signal increases. This setup allowed us to obtain two signals from one measurement and use the ratio to construct a standard curve, significantly reducing the possibility of misjudgment. Under optimal conditions, the linear detection range for MCP-1 is 10-2.5 pg mL- 1 to 103 pg mL-1, with a detection limit of 1.6 fg mL- 1 (S / N = 3). The immunosensor also exhibited excellent selectivity, repeatability, and stability, expanding the application of the dual luminescence mechanism and providing an effective method for early monitoring of cardiovascular disease.
引用
收藏
页数:8
相关论文
共 25 条
[1]   Resonance energy transfer in ZnS:Mn crystals in the processes of photoluminescence and electroluminescence [J].
Bulanyi, MF ;
Gorban', AN ;
Kovalenko, AV ;
Polezhaev, BA .
OPTICS AND SPECTROSCOPY, 2003, 94 (03) :384-388
[2]   A Low-Toxic Colloidal Quantum Dots Sensitized IGZO Phototransistor Array for Neuromorphic Vision Sensors [J].
Chen, Tong ;
Zhan, Shijie ;
Li, Benxuan ;
Hou, Bo ;
Zhou, Hang .
ADVANCED OPTICAL MATERIALS, 2024, 12 (11)
[3]   Radiolabeled monocyte chemotactic protein I for the detection of inflammation in experimental atherosclerosis [J].
Hartung, Dagmar ;
Petrov, Artiom ;
Haider, Nezam ;
Fujimoto, Shinichiro ;
Blankenberg, Francis ;
Fujimoto, Ai ;
Virmani, Renu ;
Kolodgie, Frank D. ;
Strauss, H. William ;
Narula, Jagat .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (11) :1816-1821
[4]   Hypoxia-sensitive molecules may modulate the development of atherosclerosis in sleep apnoea syndrome [J].
Hayashi, M ;
Fujimoto, K ;
Urushibata, K ;
Takamizawa, A ;
Kinoshita, O ;
Kubo, K .
RESPIROLOGY, 2006, 11 (01) :24-31
[5]   Three monocyte-related determinants of atherosclerosis in haemodialysis [J].
Jacobson, SH ;
Thylén, P ;
Lundahl, J .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (09) :1414-1419
[6]   Multifunctional protein particles with dual analytical channels for colorimetric enzymatic bioassays and fluorescent immunoassays [J].
Lai, Kwok Kei ;
Renneberg, Reinhard ;
Mak, Wing Cheung .
BIOSENSORS & BIOELECTRONICS, 2012, 32 (01) :169-176
[7]   Ultrasensitive electrochemical immunosensor based on orderly oriented conductive wires for the detection of human monocyte chemotactic protein-1 in serum [J].
Li, Yuliang ;
He, Junlin ;
Xia, Chunyong ;
Gao, Liuliu ;
Yu, Chao .
BIOSENSORS & BIOELECTRONICS, 2015, 70 :392-397
[8]   A sensitive sandwich-type immunosensor for the detection of MCP-1 based on a rGO-TEPA-Thi-Au nanocomposite and novel RuPdPt trimetallic nanoalloy particles [J].
Mao, Weiran ;
He, Junlin ;
Tang, Zhiyong ;
Zhang, Chengli ;
Chen, Jun ;
Li, Jia ;
Yu, Chao .
BIOSENSORS & BIOELECTRONICS, 2019, 131 :67-73
[9]   CCL2 polymorphisms are associated with serum monocyte chemoattractant protein-1 levels and myocardial infarction in the framingham heart study [J].
McDermott, DH ;
Yang, Q ;
Kathiresan, S ;
Cupples, LA ;
Massaro, JM ;
Keaney, JF ;
Larson, MG ;
Vasan, RS ;
Hirschhorn, JN ;
O'Donnell, CJ ;
Murphy, PM ;
Benjamin, EJ .
CIRCULATION, 2005, 112 (08) :1113-1120
[10]   Metabolic biomarkers for predicting cardiovascular disease [J].
Montgomery, Jana E. ;
Brown, Jeremiah R. .
VASCULAR HEALTH AND RISK MANAGEMENT, 2013, 9 :37-45