Multi-Stage and Multi-Objective Feed-in Damping-Based Battery Aging-Aware Energy Management Strategy for Renewable Energy Integration

被引:1
作者
Terkes, Musa [1 ]
Demirci, Alpaslan [1 ]
Gokalp, Erdin [1 ]
Cali, Umit [2 ,3 ]
机构
[1] Yildiz Tech Univ, Dept Elect Engn, TR-34220 Istanbul, Turkiye
[2] Norwegian Univ Sci & Technol, Dept Elect Power Engn, N-7034 Trondheim, Norway
[3] Univ York, Sch Phys Engn & Technol, York YO10 5DD, England
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Batteries; Costs; Degradation; Energy management; State of charge; Electricity; Aging; Battery management systems; Hybrid power systems; Battery control strategies; degradation costs; battery aging; calendar and cycle degradation; energy management; hybrid power systems; feasibility analysis; STORAGE-SYSTEMS; OPERATIONAL STRATEGIES; SELF-CONSUMPTION; OPTIMIZATION; CAPACITY; COST;
D O I
10.1109/ACCESS.2024.3468716
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Battery control strategies are crucial in optimizing energy storage systems' performance and economic feasibility. A comprehensive analysis of battery control strategies should include an integrated perspective considering optimal battery capacities, life cycle cost (LCC), self-consumption rates (SCR), and battery degradation. This study proposed a multi-stage and multi-objective feed-in damping-based energy management strategy that minimizes LCC using a two-layer solution and considers long-term battery degradation. In the first stage, the optimal battery capacities are determined by the particle swarm optimization (PSO) algorithm without considering battery aging. In the second stage, the performance of the proposed multi-objective feed-in damping-based energy management strategy (MOFD) sensitive to battery aging is evaluated. Also, the performance of the developed strategy is assessed against traditional control architectures in terms of various technical, economic and environmental decision criteria. The results show that optimal capacity allocation increases renewable potential by up to 37.4% compared to basic sizing approaches. The proposed method that considers battery degradation has lower LCC and reduces curtailment energy by up to 18.4%. Conversely, battery degradation can cause up to 2% reductions in throughput. It has shown that it will provide a more accurate and realistic evaluation procedure for battery control strategies' long-term sustainability and cost-effectiveness.
引用
收藏
页码:161401 / 161416
页数:16
相关论文
共 51 条
  • [1] Battery energy storage control using a reinforcement learning approach with cyclic time-dependent Markov process
    Abedi, Sara
    Yoon, Sang Won
    Kwon, Soongeol
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 134
  • [2] Ahmed Engr Ali, 2023, 2023 International Multi-disciplinary Conference in Emerging Research Trends (IMCERT), P1, DOI 10.1109/IMCERT57083.2023.10075113
  • [3] Ahmed E. E. E ..., 2022, P INT C HUM COMP INT, P1
  • [4] Optimal sizing of battery energy storage in a microgrid considering capacity degradation and replacement year
    Amini, Mohammad
    Khorsandi, Amir
    Vahidi, Behrooz
    Hosseinian, Seyed Hossein
    Malakmahmoudi, Ali
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195
  • [5] Comparison of different operation strategies for PV battery home storage systems including forecast-based operation strategies
    Angenendt, Georg
    Zurmuehlen, Sebastian
    Axelsen, Hendrik
    Sauer, Dirk Uwe
    [J]. APPLIED ENERGY, 2018, 229 : 884 - 899
  • [6] Enhancing Battery Lifetime In PV Battery Home Storage System Using Forecast Based Operating Strategies
    Angenendt, Georg
    Zurmuehlen, Sebastian
    Mir-Montazeri, Ramin
    Magnor, Dirk
    Sauer, Dirk Uwe
    [J]. 10TH INTERNATIONAL RENEWABLE ENERGY STORAGE CONFERENCE, IRES 2016, 2016, 99 : 80 - 88
  • [7] PV self-consumption optimization with storage and Active DSM for the residential sector
    Castillo-Cagigal, M.
    Caamano-Martin, E.
    Matallanas, E.
    Masa-Bote, D.
    Gutierrez, A.
    Monasterio-Huelin, F.
    Jimenez-Leube, J.
    [J]. SOLAR ENERGY, 2011, 85 (09) : 2338 - 2348
  • [8] Hybrid renewable power plant sizing - Graphical decision tool, sensitivity analysis and applications in Ajaccio and Tilos
    Duchaud, Jean-Laurent
    Notton, Gilles
    Fouilloy, Alexis
    Voyant, Cyril
    [J]. APPLIED ENERGY, 2019, 254
  • [9] Optimal sizing of PV-BESS units for home energy management system-equipped households considering day-ahead load scheduling for demand response and self-consumption
    Duman, A. Can
    Erden, Hamza Salih
    Gonuel, Omer
    Guler, Onder
    [J]. ENERGY AND BUILDINGS, 2022, 267
  • [10] Optimization of the scheduling and operation of prosumers considering the loss of life costs of battery storage systems
    Faraji, Jamal
    Ketabi, Abbas
    Hashemi-Dezaki, Hamed
    [J]. JOURNAL OF ENERGY STORAGE, 2020, 31