Development and Validation of a Single Stability-Indicating Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Identification and Assay of Eprinomectin in Two Different Commercial Injectable Drug Products for Cattle

被引:0
|
作者
Dharmaratne, Nayanthara U. [1 ]
Rustum, Abu M. [1 ]
机构
[1] Boehringer Ingelheim Anim Hlth BIAH USA, Global Pharmaceut Tech Support, 631 US Route 1 South, North Brunswick, NJ 08902 USA
关键词
DEGRADATION-PRODUCTS; LC;
D O I
10.1093/jaoacint/qsaf006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background Eprinomectin (EPRN) is a semi-synthetic macrocyclic lactone exhibiting antiparasitic activity and is widely used as an active pharmaceutical ingredient (API) in veterinary drug products.Objective This study aimed to develop a single stability-indicating reversed-phase (RP)-HPLC method to identify and assay EPRN in two different injectable drug products for cattle.Methods The RP-HPLC method is carried out on a Halo-C18 column (100 mm x 4.6 mm id, 2.7 mu m particle size) maintained at 55 degrees C. The analytes are separated by a gradient elution at a flow rate of 0.8 mL/min and detected at a wavelength of 245 nm. The mobile phase-A (MPA) of the method is 0.1% (v/v) aqueous perchloric acid, and mobile phase-B (MPB) is ethanol (EtOH). The Ascentis Express C18 column (100 mm x 4.6 mm id, 2.7 mu m particle size) was identified and validated as an equivalent column for the prescribed method.Results The RP-HPLC method described in this article can adequately separate all major related substances of EPRN in the two drug products from EPRN B1a and EPRN B1b within 20 min.Conclusion The developed RP-HPLC method for the identification and assay of EPRN was successfully validated in accordance with the guidelines outlined in the International Conference on Harmonization (ICH) Q2(R2), and demonstrated to be robust, linear, accurate, precise, specific, and stability-indicating.Highlights The new RP-HPLC method exhibits a higher level of selectivity but is yet rapid and simple, making it suitable for routine and non-routine analysis in research and QC laboratories.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Determination of chlorotoluron in technical products and formulations by reversed-phase high performance liquid chromatography (RP-HPLC)
    Yan, WY
    Li, SQ
    Zheng, ZB
    PESTICIDE SCIENCE, 1997, 49 (04): : 400 - 401
  • [22] Development and Validation of a Stability-Indicating RP-HPLC Method for Determination of Eprinomectin, its Degradation Products, and Butylated Hydroxytoluene in a Pour-On Finished Product
    Nilusha Padivitage
    Lin Wang
    Rasangi M. Wimalasinghe
    Abu M. Rustum
    Chromatographia, 2021, 84 : 949 - 965
  • [23] Development and Validation of a Stability-Indicating RP-HPLC Method for Determination of Eprinomectin, its Degradation Products, and Butylated Hydroxytoluene in a Pour-On Finished Product
    Padivitage, Nilusha
    Wang, Lin
    Wimalasinghe, Rasangi M.
    Rustum, Abu M.
    CHROMATOGRAPHIA, 2021, 84 (10) : 949 - 965
  • [24] Development and Validation of a Stability-Indicating Reversed-Phase HPLC Method for Assay and Estimation of Related Substances of Ivermectin in an Oral Paste
    Padivitage, Nilusha
    Tian, Jingzhi
    Wang, Lin
    Zhuang, Jinyou
    McAdoo, Andrew
    Zhao, Daoli
    Rustum, Abu M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023, 61 (02) : 119 - 129
  • [25] Development and Validation of a Stability-Indicating Reversed-Phase Ultra High Pressure Liquid Chromatography Method for Assay of Delmopinol Hydrochloride and Estimation of Its Related Substances in Commercial Bulk Batches
    Zhuang, Jinyou
    Rustum, Abu M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (09) : 880 - 886
  • [26] STABILITY-INDICATING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ASSAY FOR BEPRIDIL HYDROCHLORIDE DRUG SUBSTANCE AND DRUG PRODUCTS
    RENZI, NL
    FRONHEISER, ME
    DUONG, HT
    FULTON, DJ
    RABINOWITZ, M
    JOURNAL OF CHROMATOGRAPHY, 1989, 462 : 398 - 405
  • [27] DEVELOPMENT AND VALIDATION OF REPAGLINIDE BY REVERSED PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (RP-HPLC) IN TABLET DOSAGE FORMS
    Begum, Ayesha K.
    Pamu, Sandhya
    Kodali, Geetha
    Kasu, Pavani
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 1 (03): : 142 - 150
  • [28] Development and validation of reversed phase high performance liquid chromatography (RP-HPLC) for quantification of captopril in rabbit plasma
    Rasool, Muhammad Fawad
    Qureshi, Umbreen Fatima
    Ranjha, Nazar Muhammad
    Imran, Imran
    Nisa, Mouqadus Un
    Majeed, Abdul
    ACTA CHROMATOGRAPHICA, 2021, 33 (04) : 315 - 321
  • [29] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIFFERENTIAL PULSE POLAROGRAPHIC DETECTION FOR ASSAYING DRUGS IN FEED - STABILITY-INDICATING ASSAY OF DIACETOLOL
    SCHIEFFER, GW
    JOURNAL OF CHROMATOGRAPHY, 1980, 202 (03): : 405 - 412
  • [30] Lipophilicity measurement by reversed-phase high-performance liquid chromatography (RP-HPLC): A comparison of two stationary phases based on retention mechanisms
    Liu, XL
    Tanaka, H
    Yamauchi, A
    Testa, B
    Chuman, H
    HELVETICA CHIMICA ACTA, 2004, 87 (11) : 2866 - 2876