Analysis of Influence of Grid-Following and Grid-Forming Static Var Generators on High-Frequency Resonance in Doubly Fed Induction Generator-Based Wind Farms

被引:1
作者
Sun, Yong [1 ]
Wu, Hongbin [2 ]
Song, Xiaozhe [3 ]
Zhang, Haifeng [4 ]
Zhang, Yifu [4 ]
Chen, Jikai [2 ]
Liu, Hongpeng [2 ]
机构
[1] Jilin Elect Power Co Ltd, Power Econ Res Inst, Changchun 130021, Peoples R China
[2] Northeast Elect Power Univ, Sch Elect Engn, Jilin 132012, Peoples R China
[3] State Grid Jilin Elect Power Co Ltd, Changchun 130021, Peoples R China
[4] State Grid Jilin Elect Power Res Inst, Changchun 130021, Peoples R China
关键词
DFIG-based wind farm; GFM control; high-frequency resonance; static var generator; sequential impedance modeling; VOLTAGE-SOURCE; STABILITY; HVDC;
D O I
10.3390/electronics13193879
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In Doubly Fed Induction Generator (DFIG)-based wind farms with Static Var Generators (SVGs), high-frequency resonance will be more like to occur when an unloaded cable is put into operation, which will threaten the stable operation of the wind farm. To address this issue, the influence of power outer loops on the impedance of grid-connected inverters is considered. Based on harmonic linearization, theoretical models for the sequence impedances of DFIGs, Grid-following (GFL) SVGs, and Grid-forming (GFM) SVGs are established. The correctness of the three models is verified by impedance scanning using the frequency sweep method. Through a comparative analysis of these sequence impedances, it is found that unlike the GFM SVG (which exhibits inductive impedance), the GFL SVG exhibits capacitive impedance in the high-frequency band, which leads to negative damping characteristics in the high-frequency band for the wind farm system with the grid-following SVG; thereby, the risk of high-frequency resonance also increases accordingly. On the contrary, GFM control adopted by SVGs can effectively eliminate the negative damping region in the high-frequency band for wind farms to suppress high-frequency resonance. Meanwhile, for grid-forming SVGs, the parameter variations in power synchronous loops have no significant impact on the suppressing effect of high-frequency resonance for wind farms. Finally, an electromagnetic simulation model for a DFIG-based wind farm system with an SVG is established using the StarSim-HIL (hardware-in-the-loop) experiment platform, and the simulation results validate the correctness of the theoretical analysis.
引用
收藏
页数:21
相关论文
共 32 条
  • [11] Parallel Impedance-Reshaping Control Strategy for Suppressing Wide Range High-Frequency Resonance of Shunt Compensated DFIG System
    Li, Canbing
    Chen, Dawei
    Wei, Juan
    Wu, Qiuwei
    Yu, Hao
    Zhang, Xing
    Ren, Wanxin
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (05) : 5672 - 5681
  • [12] An Enhancing Grid Stiffness Control Strategy of STATCOM/BESS for Damping Sub-Synchronous Resonance in Wind Farm Connected to Weak Grid
    Li, Gaoxiang
    Chen, Yandong
    Luo, An
    Wang, Haining
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2020, 16 (09) : 5835 - 5845
  • [13] [刘承锡 Liu Chengxi], 2023, [电网技术, Power System Technology], V47, P3980
  • [14] MMC-STATCOM supplementary wide-band damping control to mitigate subsynchronous control interaction in wind farms
    Liu, Yiqi
    Zheng, Junyuan
    Chen, Qichao
    Duan, Zhaoyu
    Tian, Yuhong
    Ban, Mingfei
    Li, Zhenjie
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [15] An active damping control method for direct-drive wind farm with flexible DC transmission system based on the remodeling of dynamic energy branches
    Ma, Jing
    Yang, Zhenmiao
    Du, Wangyang
    Shen, Yaqi
    Cheng, Peng
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [16] Mechanism Analysis and Damping Method for High Frequency Resonance Between VSC-HVDC and the Wind Farm
    Pang, Bo
    Nian, Heng
    Xu, Yunyang
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (02) : 984 - 994
  • [17] A Modified Sequence-Domain Impedance Definition and Its Equivalence to the dq-Domain Impedance Definition for the Stability Analysis of AC Power Electronic Systems
    Rygg, Atle
    Molinas, Marta
    Zhang, Chen
    Cai, Xu
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (04) : 1383 - 1396
  • [18] Effect of wind turbine converter control on wind power plant harmonic response and resonances
    Sainz, Luis
    Monjo, Lluis
    Pedra, Joaquin
    Cheah-Mane, Marc
    Liang, Jun
    Gomis-Bellmunt, Oriol
    [J]. IET ELECTRIC POWER APPLICATIONS, 2017, 11 (02) : 157 - 168
  • [19] Analysis of High-Frequency Resonance in DFIG-Based Offshore Wind Farm via Long Transmission Cable
    Song, Yipeng
    Ebrahimzadeh, Esmaeil
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (03) : 1036 - 1046
  • [20] Analysis and Active Damping of Multiple High Frequency Resonances in DFIG System
    Song, Yipeng
    Blaabjerg, Frede
    Wang, Xiongfei
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (01) : 369 - 381