Ultrasound Derived Inferior Vena Cava Diameter and Collapsibility Index to Predict Central Venous Pressure Prior and After A Fluid Challenge in Spontaneous Breathing Preoperative Patients

被引:0
作者
Talreja, Neha Gopal [1 ]
Shetty, Vijay [1 ]
机构
[1] Fortis Hosp Mulund Goregaon Link Rd, Mumbai 400078, Maharashtra, India
关键词
Central venous pressure (CVP); collapsibility index (CI); inferior vena cava (IVC) diameters; passive leg raising (PLR); RIGHT ATRIAL PRESSURE; NONINVASIVE ESTIMATION; EUROPEAN-ASSOCIATION; AMERICAN-SOCIETY; RIGHT-HEART; RESPONSIVENESS; VOLUME; ECHOCARDIOGRAPHY; ULTRASONOGRAPHY; GUIDELINES;
D O I
10.21608/ASJA.2024.250976.1021
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Central venous pressure (CVP) is indicator of preload and used to determine intravascular volume status. An invasive method such as central venous catheter placement is required in order to measure CVP. However, it is associated with many complications. Instead, sonographic measurement of inferior vena cava (IVC) represents effective and noninvasive method of estimating CVP and recommendations are provided by the American Society of Echocardiography (ASE). There are various methods to calculate and estimate CVP using ultrasound. One of the ultrasonographic (US) technique for obtaining the JVP from a high-resolution B-mode sonogram sequences (US-JVP), recording the changes in IJV-CSA (cross section area) over the cardiac cycle (CC) has been proposed which appears to have potential as an approach for estimating CVP. Patients and Methods: It is a prospective double blinded observational study conducted at tertiary hospital among 40 consenting patients. Results: We found that 27 patients (67.5%) had correct prediction of CVP by USG with measured CVP after transducing central venous catheter at baseline (supine position). Similarly, 19 patients (47.5%) had correct prediction of CVP with measured CVP after passive leg raising. We found that 14 patients (35%) had 10% rise in mean arterial pressure on passive leg raising. We denoted these patients as Responders. We found that both responders and non-responders had poor correlation with CVP prediction. Also IVC diameters and collapsibility index did not predict the fluid responsiveness of the patients. Spearman correlation coefficient was used to study correlation between two quantitative variables. In our study, we found a strong positive correlation between predicted CVP (determined by USG parameters) and measured CVP (determined by transducing central venous catheter on monitor) at baseline (supine position) and after passive leg raising. Multivariate regression analysis was done to find the significant predictor of CVP which was found to be IVC maximum diameter (p value 0.01) determined by USG. Conclusion: Bedside USG in preoperative patients can be used as a simple and reliable method to calculate IVC diameters and collapsibility index to predict CVP. It requires minimal training and correlates well with real time transduced CVP. In our study of 40 patients we aimed to study the ability of the ultrasound guided measurements of the Inferior Vena Cava in predicting the Central Venous Pressure (CVP). A strong positive correlation was found between the predicted CVP and measured/transduced CVP in supine position 8 (baseline) and after passive leg raising. On multivariate regression analysis, the IVC maximum diameter determined by USG was found to be the significant predictor of CVP. No significant correlation was noted between IVC parameters, Collapsibility index and CVP values to predict fluid responsive nature of the patients.
引用
收藏
页数:10
相关论文
共 33 条
[1]   Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients? [J].
Airapetian, Norair ;
Maizel, Julien ;
Alyamani, Ola ;
Mahjoub, Yazine ;
Lorne, Emmanuel ;
Levrard, Melanie ;
Ammenouche, Nacim ;
Seydi, Aziz ;
Tinturier, Francois ;
Lobjoie, Eric ;
Dupont, Herve ;
Slama, Michel .
CRITICAL CARE, 2015, 19
[2]  
Ali MK, 2018, Indian Journal of Child Health, V5, P562
[3]   Noninvasive Evaluation of Right Atrial Pressure [J].
Beigel, Roy ;
Cercek, Bojan ;
Luo, Huai ;
Siegel, Robert J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (09) :1033-1042
[4]   Respiratory variation in inferior vena cava diameter: surrogate of central venous pressure or parameter of fluid responsiveness? Let the physiology reply [J].
Bodson, Laurent ;
Vieillard-Baron, Antoine .
CRITICAL CARE, 2012, 16 (06)
[5]   Reappraisal of the use of inferior vena cava for estimating right atrial pressure [J].
Brennan, J. Matthew ;
Blair, John E. ;
Goonewardena, Sascha ;
Ronan, Adam ;
Shah, Dipak ;
Vasaiwala, Samip ;
Kirkpatrick, James N. ;
Spencer, Kirk T. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (07) :857-861
[6]  
Capomolla S, 2000, Ital Heart J, V1, P684
[7]   The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure [J].
Ciozda, William ;
Kedan, Ilan ;
Kehl, Devin W. ;
Zimmer, Raymond ;
Khandwalla, Raj ;
Kimchi, Asher .
CARDIOVASCULAR ULTRASOUND, 2016, 14
[8]  
Citilcioglu S, 2014, PAK J MED SCI, V30, P310
[9]   2019 ACC/AHA/ASE Key Data Elements and Definitions for Transthoracic Echocardiography: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Data Standards (Writing Committee to Develop Clinical Data Standards for Transthoracic Echocardiography) and the American Society of Echocardiography [J].
Douglas, Pamela S. ;
Carabello, Blase A. ;
Lang, Roberto M. ;
Lopez, Leo ;
Pellikka, Patricia A. ;
Picard, Michael H. ;
Thomas, James D. ;
Varghese, Paul ;
Wang, Tracy Y. ;
Weissman, Neil J. ;
Wilgus, Rebecca .
CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (07)
[10]   Comparative evaluation of central venous pressure and sonographic inferior vena cava variability in assessing fluid responsiveness in septic shock [J].
Garg, Manjri ;
Sen, Jyotsna ;
Goyal, Sandeep ;
Chaudhry, Dhruva .
INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2016, 20 (12) :708-713