摘要
Abnormal levels of thrombin may be associated with various diseases, such as thrombosis and hemorrhagic diseases, making precise detection of thrombin particularly important. Dual signal detection is a method that enhances detection sensitivity and specificity by simultaneously utilizing two different signals. Its primary advantages include improving detection accuracy and reducing false positive rates, making it particularly suitable for clinical analysis and diagnostics. In this work, we developed a dual signal detection method for thrombin based on DNA self-assembly. This design incorporates an X-DNA structure. The two bottom arms of the X-shaped DNA (X-DNA) are designed to bind to CuInS2 nanoparticles via dehydration reactions between amine and carboxyl groups. The two top arms of the X-DNA are designed to hybridize with complementary DNA/glucose oxidase (GOx) and DNA/ferrocene (Fc), respectively. Thrombin triggers the hybridization of DNA/GOx and XDNA, simultaneously causing the dissociation of DNA/Fc from X-DNA. In the Photoelectrochemical mode, GOx can react with O2 and glucose in the detection solution, resulting in a corresponding decrease in the amount of O2 acting as an electron acceptor and a decrease in the photoelectric signal. In the Differential Pulse Voltammetry mode, due to the decrease in Fc content, the DPV signal also shows a weakening trend. The detection method exhibits a good linear relationship within the range of 10 fM -10 nM, with a detection limit of 6.89 fM and 5.86 fM. The enhanced analytical sensitivity and specificity of dual signal detection technology offer broad prospects for improving disease diagnosis.
引用
收藏
页数:8
相关论文
共 39 条
  • [1] Molecular digital data storage using DNA
    Ceze, Luis
    Nivala, Jeff
    Strauss, Karin
    [J]. NATURE REVIEWS GENETICS, 2019, 20 (08) : 456 - 466
  • [2] Aptamer-Based SERRS Sensor for Thrombin Detection
    Cho, Hansang
    Baker, Brian R.
    Wachsmann-Hogiu, Sebastian
    Pagba, Cynthia V.
    Laurence, Ted A.
    Lane, Stephen M.
    Lee, Luke P.
    Tok, Jeffrey B. -H.
    [J]. NANO LETTERS, 2008, 8 (12) : 4386 - 4390
  • [3] Thrombin: Coagulation's master regulator of innate immunity
    Conway, Edward M.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2019, 17 (11) : 1785 - 1789
  • [4] Deconvoluting the structural and drug-recognition complexity of the G-quadruplex-forming region upstream of the bcl-2 P1 promoter
    Dexheimer, TS
    Sun, D
    Hurley, LH
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (16) : 5404 - 5415
  • [5] Self-powered photoelectrochemical sensor activated by In2O3/ CdTe@ZnS-photoanode coupled with manganese porphyrin-double quenching for methyltransferase detection
    Dong, Wenshuai
    Li, Zhikang
    Wang, Bing
    Jie, Guifen
    Zhou, Hong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2024, 398
  • [6] Purification of DNA Nanoparticles Using Photocleavable Biotin Tethers
    Everson H.R.
    Neyra K.
    Scarton D.V.
    Chandrasekhar S.
    Green C.M.
    Schmidt T.-L.
    Medintz I.L.
    Veneziano R.
    Mathur D.
    [J]. ACS Applied Materials and Interfaces, 2024, 16 (17) : 22334 - 22343
  • [7] Efficient storage of high throughput DNA sequencing data using reference-based compression
    Fritz, Markus Hsi-Yang
    Leinonen, Rasko
    Cochrane, Guy
    Birney, Ewan
    [J]. GENOME RESEARCH, 2011, 21 (05) : 734 - 740
  • [8] Precise Simulation Model for DNA Tile Self-Assembly
    Fujibayashi, Kenichi
    Murata, Satoshi
    [J]. IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2009, 8 (03) : 361 - 368
  • [9] Supersandwich Nanowire/Quantum Dots Sensitization Structure-Based Photoelectrochemical "Signal-On" Platform for Ultrasensitive Detection of Thrombin
    Gao, Xiaoshan
    Cai, Qianqian
    Li, Hongkun
    Jie, Guifen
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (09) : 6734 - 6740
  • [10] An electrochemical impedance sensor based on a small molecule modified Au electrode for the recognition of a trinucleotide repeat
    He, Hanping
    Peng, Xiaoqian
    Huang, Min
    Chang, Gang
    Zhang, Xiuhua
    Wang, Shengfu
    [J]. ANALYST, 2014, 139 (21) : 5482 - 5487