Artificial intelligence for diagnosing exudative age-related macular degeneration

被引:0
作者
Kang, Chaerim [1 ]
Lo, Jui-En [2 ]
Zhang, Helen [3 ]
Ng, Sueko M. [4 ]
Lin, John C. [5 ]
Scott, Ingrid U. [6 ]
Kalpathy-Cramer, Jayashree [4 ]
Liu, Su-Hsun [4 ,7 ]
Greenberg, Paul B. [1 ,8 ]
机构
[1] Brown Univ, Div Ophthalmol, Providence, RI USA
[2] Case Western Reserve Univ, Dept Internal Med, MetroHealth Med Ctr, Cleveland, OH USA
[3] Brown Univ, Program Liberal Med Educ, Providence, RI USA
[4] Univ Colorado, Dept Ophthalmol, Anschutz Med Campus, Aurora, CO USA
[5] Univ Pennsylvania, Dept Med, Perelman Sch Med, Philadelphia, PA USA
[6] Penn State Coll Med, Dept Ophthalmol & Publ Hlth Sci, Hershey, PA USA
[7] Univ Colorado, Dept Epidemiol, Anschutz Med Campus, Aurora, CO USA
[8] VA Prov Healthcare Syst, Sect Ophthalmol, Providence, RI USA
来源
COCHRANE DATABASE OF SYSTEMATIC REVIEWS | 2024年 / 10期
关键词
OPTICAL COHERENCE TOMOGRAPHY; DISEASE-ACTIVITY PREDICTION; MACHINE LEARNING APPROACH; RETICULAR PSEUDODRUSEN; DIABETIC-RETINOPATHY; DECISION-MAKING; CLASSIFICATION; IMAGES; AMD; OCT;
D O I
10.1002/14651858.CD015522.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Age-related macular degeneration (AMD) is a retinal disorder characterized by central retinal (macular) damage. Approximately 10% to 20% of non-exudative AMD cases progress to the exudative form, which may result in rapid deterioration of central vision. Individuals with exudative AMD (eAMD) need prompt consultation with retinal specialists to minimize the risk and extent of vision loss. Traditional methods of diagnosing ophthalmic disease rely on clinical evaluation and multiple imaging techniques, which can be resource-consuming. Tests leveraging artificial intelligence (AI) hold the promise of automatically identifying and categorizing pathological features, enabling the timely diagnosis and treatment of eAMD. Objectives To determine the diagnostic accuracy of artificial intelligence (AI) as a triaging tool for exudative age-related macular degeneration (eAMD). Search methods We searched CENTRAL, MEDLINE, Embase, three clinical trials registries, and Data Archiving and Networked Services (DANS) for gray literature. We did not restrict searches by language or publication date. The date of the last search was April 2024. Selection criteria Included studies compared the test performance of algorithms with that of human readers to detect eAMD on retinal images collected from people with AMD who were evaluated at eye clinics in community or academic medical centers, and who were not receiving treatment for eAMD when the images were taken. We included algorithms that were either internally or externally validated or both. Data collection and analysis Pairs of review authors independently extracted data and assessed study quality using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool with revised signaling questions. For studies that reported more than one set of performance results, we extracted only one set of diagnostic accuracy data per study based on the last development stage or the optimal algorithm as indicated by the study authors. For two-class algorithms, we collected data from the 2x2 table whenever feasible. For multi-class algorithms, we first consolidated data from all classes other than eAMD before constructing the corresponding 2x2 tables. Assuming a common positivity threshold applied by the included studies, we chose random-effects, bivariate logistic models to estimate summary sensitivity and specificity as the primary performance metrics. Main results We identified 36 eligible studies that reported 40 sets of algorithm performance data, encompassing over 16,000 participants and 62,000 images. We included 28 studies (78%) that reported 31 algorithms with performance data in the meta-analysis. The remaining nine studies (25%) reported eight algorithms that lacked usable performance data; we reported them in the qualitative synthesis. Study characteristics and risk of bias Most studies were conducted in Asia, followed by Europe, the USA, and collaborative efforts spanning multiple countries. Most studies identified study participants from the hospital setting, while others used retinal images from public repositories; a few studies did not specify image sources. Based on four of the 36 studies reporting demographic information, the age of the study participants ranged from 62 to 82 years. The included algorithms used various retinal image types as model input, such as optical coherence tomography (OCT) images (N = 15), fundus images (N = 6), and multi-modal imaging (N = 7). The predominant core method used was deep neural networks. All studies that reported externally validated algorithms were at high risk of bias mainly due to potential selection bias from either a two-gate design or the inappropriate exclusion of potentially eligible retinal images (or participants). Findings Only three of the 40 included algorithms were externally validated (7.5%, 3/40). The summary sensitivity and specificity were 0.94 (95% confidence interval (CI) 0.90 to 0.97) and 0.99 (95% CI 0.76 to 1.00), respectively, when compared to human graders (3 studies; 27,872 images; low-certainty evidence). The prevalence of images with eAMD ranged from 0.3% to 49%. Twenty-eight algorithms were reportedly either internally validated (20%, 8/40) or tested on a development set (50%, 20/40); the pooled sensitivity and specificity were 0.93 (95% CI 0.89 to 0.96) and 0.96 (95% CI 0.94 to 0.98), respectively, when compared to human graders (28 studies; 33,409 images; low-certainty evidence). We did not identify significant sources of heterogeneity among these 28 algorithms. Although algorithms using OCT images appeared more homogeneous and had the highest summary specificity (0.97, 95% CI 0.93 to 0.98), they were not superior to algorithms using fundus images alone (0.94, 95% CI 0.89 to 0.97) or multimodal imaging (0.96, 95% CI 0.88 to 0.99; P for meta-regression = 0.239). The median prevalence of images with eAMD was 30% (interquartile range [IQR] 22% to 39%). We did not include eight studies that described nine algorithms (one study reported two sets of algorithm results) to distinguish eAMD from normal images, images of other AMD, or other non-AMD retinal lesions in the meta-analysis. Five of these algorithms were generally based on smaller datasets (range 21 to 218 participants per study) yet with a higher prevalence of eAMD images (range 33% to 66%). Relative to human graders, the reported sensitivity in these studies ranged from 0.95 and 0.97, while the specificity ranged from 0.94 to 0.99. Similarly, using small datasets (range 46 to 106), an additional four algorithms for detecting eAMD from other retinal lesions showed high sensitivity (range 0.96 to 1.00) and specificity (range 0.77 to 1.00). Authors' conclusions Low- to very low-certainty evidence suggests that an algorithm-based test may correctly identify most individuals with eAMD without increasing unnecessary referrals (false positives) in either the primary or the specialty care settings. There were significant concerns for applying the review findings due to variations in the eAMD prevalence in the included studies. In addition, among the included algorithm-based tests, diagnostic accuracy estimates were at risk of bias due to study participants not reflecting real-world characteristics, inadequate model validation, and the likelihood of selective results reporting. Limited quality and quantity of externally validated algorithms highlighted the need for high-certainty evidence. This evidence will require a standardized definition for eAMD on different imaging modalities and external validation of the algorithm to assess generalizability.
引用
收藏
页数:222
相关论文
共 50 条
  • [41] Clinical and genetic characteristics of pachydrusen in patients with exudative age-related macular degeneration
    Fukuda, Yoshiko
    Sakurada, Yoichi
    Yoneyama, Seigo
    Kikushima, Wataru
    Sugiyama, Atsushi
    Matsubara, Mio
    Tanabe, Naohiko
    Iijima, Hiroyuki
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [42] Perspectives on reticular pseudodrusen in age-related macular degeneration
    Sivaprasad, Sobha
    Bird, Alan
    Nitiahpapand, Rynda
    Nicholson, Luke
    Hykin, Phil
    Chatziralli, Irini
    SURVEY OF OPHTHALMOLOGY, 2016, 61 (05) : 521 - 537
  • [43] Lamellar Macular Holes Associated with End-Stage Exudative Age-Related Macular Degeneration
    Segal, Ori
    Ferencz, Joseph R.
    Mimouni, Michael
    Nesher, Ronit
    Cohen, Perri
    Nemet, Arie Y.
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2015, 17 (12): : 750 - 754
  • [44] OCT angiography for exudative age-related macular degeneration. Initial experiences
    Lommatzsch, A.
    Farecki, M. -L.
    Book, B.
    Heimes, B.
    Pauleikhoff, D.
    OPHTHALMOLOGE, 2016, 113 (01): : 23 - 29
  • [45] Exudative versus Nonexudative Age-Related Macular Degeneration: Physiopathology and Treatment Options
    Rita Fernandes, Ana
    Zielinska, Aleksandra
    Sanchez-Lopez, Elena
    dos Santos, Tiago
    Luisa Garcia, Maria
    Silva, Amelia M.
    Karczewski, Jacek
    Souto, Eliana B.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (05)
  • [46] Subfoveal choroidal thickness as a prognostic factor in exudative age-related macular degeneration
    Kumar, Jaya B.
    Wai, Karen M.
    Ehlers, Justin P.
    Singh, Rishi P.
    Rachitskaya, Aleksandra V.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (07) : 918 - 921
  • [47] Impact of mydriatic eyedrops on distance visual acuity in patients with exudative age-related macular degeneration
    Haution, D.
    Lala, E.
    Le Lez, M. L.
    Laube, N.
    Serrhini, C.
    Jean-Lechner, M.
    Dorvault, M.
    Pisella, P-J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (08): : 880 - 893
  • [48] Synthetic artificial intelligence using generative adversarial network for retinal imaging in detection of age-related macular degeneration
    Wang, Zhaoran
    Lim, Gilbert
    Ng, Wei Yan
    Tan, Tien-En
    Lim, Jane
    Lim, Sing Hui
    Foo, Valencia
    Lim, Joshua
    Sinisterra, Laura Gutierrez
    Zheng, Feihui
    Liu, Nan
    Tan, Gavin Siew Wei
    Cheng, Ching-Yu
    Cheung, Gemmy Chui Ming
    Wong, Tien Yin
    Ting, Daniel Shu Wei
    FRONTIERS IN MEDICINE, 2023, 10
  • [49] Application of Artificial Intelligence Models to Predict the Onset or Recurrence of Neovascular Age-Related Macular Degeneration
    Sorrentino, Francesco Saverio
    Zeppieri, Marco
    Culiersi, Carola
    Florido, Antonio
    De Nadai, Katia
    Adamo, Ginevra Giovanna
    Pellegrini, Marco
    Nasini, Francesco
    Vivarelli, Chiara
    Mura, Marco
    Parmeggiani, Francesco
    PHARMACEUTICALS, 2024, 17 (11)
  • [50] MACULAR CHOROIDAL VOLUME CHANGES AFTER INTRAVITREAL BEVACIZUMAB FOR EXUDATIVE AGE-RELATED MACULAR DEGENERATION
    Palkovits, Stefan
    Seidel, Gerald
    Pertl, Laura
    Malle, Eva M.
    Hausberger, Silke
    Makk, Johanna
    Singer, Christoph
    Osterholt, Julia
    Herzog, Sereina A.
    Haas, Anton
    Weger, Martin
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (12): : 2262 - 2268