Mechanical evaluation for the finite element analysis of intramedullary nailing and plate screw system used in humerus transverse fractures

被引:2
作者
Akkurt, Ekrem [1 ]
Yildirim, Mucahid [2 ]
Erenler, Ferhat [3 ]
Tosun, Osman Mucahit [4 ]
Akkurt, Mustafa Ferit [5 ]
Akkurt, Burcu [6 ]
Sen, Zafer [7 ]
Olcar, Ahmet Hamdi [8 ]
机构
[1] Konya Beyhekim Training & Res Hosp, Dept Phys Med & Rehabil, Devlethane St 2-A, TR-42060 Selcuklu, Konya, Turkiye
[2] Necmettin Erbakan Univ, Fac Dent, Dept Orthodont, Konya, Turkiye
[3] Acibadem Bakirkoy Hosp, Dept Anesteziol & Reanimat, Istanbul, Turkiye
[4] Konya Numune Hosp, Dept Anestesiol & Reanimat, Konya, Turkiye
[5] Istanbul Gelisim Univ, Fac Hlth Sci, Istanbul, Turkiye
[6] Bezmialem Vakif Univ, Phys Med & Rehabil Dept, Istanbul, Turkiye
[7] Baskent Univ, Konya Applicat & Res Ctr, Orthoped & Traumatol, Konya, Turkiye
[8] Kastamonu Training & Res Hosp, Kastamonu, Turkiye
关键词
Intramedullary nailing; Humerus fractures; Plate screw system; Finite element analysis; FIXATION; BONE;
D O I
10.1016/j.jor.2023.10.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: This study aims to examine the commonly used plate screw system and intramedullary nailing method in osteosynthesis in humeral shaft fractures in terms of stress shielding using finite element analysis. Material and methods: Images were obtained by computerized tomography (CT) to create a 3D model of the humerus bone. After the CT images were transferred to the ANSYS 2021 R2 program (ANSYS, Inc., Canons-burg, PA), a transverse fracture model was created from the shaft region of the humeral bone meshed to the humerus bone and modeled in the 3D environment. Results: The tetrahedron mesh structure was used for the finite element models in our study. The element size was chosen as 3.5 mm for the bone model and 2 mm for the plate and intramedullary nail models. The node numbers of bone, intramedullary nail, and plate were 91230, 462578, and 581352, respectively. The element numbers of bone, intramedullary nail, and plate were 61350, 311285, and 370350, respectively. Maximum stress values of 260 MPa on the nail and 280 MPa on the plate were detected in this study. Conclusion: Fewer stress values were obtained and stress concentrations were not formed on the implant in osteosynthesis performed by intramedullary nailing. It can be concluded that this study may guide further studies for those focusing on it and may contribute to the development of a more comprehensive understanding of the topic.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [41] Enhancing fixation stability in proximal humerus fractures: screw orientation optimization in PHILOS plates through finite element analysis and biomechanical testing
    Liu, Jichao
    Zhang, Ziyan
    Li, Peng
    Piao, Chengdong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [42] Plate fixation versus intramedullary nailing for displaced extra-articular distal tibia fractures: A system review
    Li B.
    Yang Y.
    Jiang L.-S.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (1) : 53 - 63
  • [43] A Retrospective Analysis of Dynamic Compression Plating Versus Intramedullary Nailing for the Management of Shaft of Humerus Fractures in an Urban Trauma Care Center
    Angachekar, Dhruva
    Patel, Shivam
    Shetty, Shaswat
    Atal, Shubham
    Dhond, Amit
    Sharma, Raunak
    Nagargoje, Pranav
    Angachekar, Dhairya
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [44] Biomechanical evaluation of intramedullary retrograde nail and dynamic condylar screw used in unstable distal femoral fractures
    Ayberk Dizdar
    Talip Celik
    Arif Ozkan
    Physical and Engineering Sciences in Medicine, 2023, 46 : 1755 - 1764
  • [45] Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
    Lingpeng Kong
    Yan Wang
    Qingsen Lu
    Yong Han
    Fu Wang
    Journal of Orthopaedic Surgery and Research, 16
  • [46] Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
    Kong, Lingpeng
    Wang, Yan
    Lu, Qingsen
    Han, Yong
    Wang, Fu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [47] Comparison of volar versus dorsal screw fixation for scaphoid waist fractures: A finite element analysis
    Acar, Baver
    Kose, Ozkan
    Kati, Yusuf Alper
    Egerci, Omer Faruk
    Turan, Adil
    Yuksel, Halil Yalcin
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (07) : 1107 - 1113
  • [48] Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty
    Chen, Shih-Hao
    Chiang, Ming-Chieh
    Hung, Ching-Hua
    Lin, Shang-Chih
    Chang, Hsiao-Wei
    KNEE, 2014, 21 (01) : 224 - 231
  • [49] Three-dimensional finite element analysis of intramedullary nail with different materials in the treatment of intertrochanteric fractures
    Wang, Chenyan
    Li, Xiaona
    Chen, Weiyi
    Wang, Changjiang
    Guo, Yuan
    Guo, Hongmei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (04): : 705 - 712
  • [50] Biomechanical Evaluation of Clival Screw Fixation for Occipitocervical Instablity: A Finite Element Analysis
    Lin, Weipeng
    Zheng, Jianying
    Zhang, Meichao
    Xu, Panjie
    Xiao, Hang
    Ji, Wei
    ORTHOPAEDIC SURGERY, 2025, 17 (02) : 583 - 592