Mechanical evaluation for the finite element analysis of intramedullary nailing and plate screw system used in humerus transverse fractures

被引:2
|
作者
Akkurt, Ekrem [1 ]
Yildirim, Mucahid [2 ]
Erenler, Ferhat [3 ]
Tosun, Osman Mucahit [4 ]
Akkurt, Mustafa Ferit [5 ]
Akkurt, Burcu [6 ]
Sen, Zafer [7 ]
Olcar, Ahmet Hamdi [8 ]
机构
[1] Konya Beyhekim Training & Res Hosp, Dept Phys Med & Rehabil, Devlethane St 2-A, TR-42060 Selcuklu, Konya, Turkiye
[2] Necmettin Erbakan Univ, Fac Dent, Dept Orthodont, Konya, Turkiye
[3] Acibadem Bakirkoy Hosp, Dept Anesteziol & Reanimat, Istanbul, Turkiye
[4] Konya Numune Hosp, Dept Anestesiol & Reanimat, Konya, Turkiye
[5] Istanbul Gelisim Univ, Fac Hlth Sci, Istanbul, Turkiye
[6] Bezmialem Vakif Univ, Phys Med & Rehabil Dept, Istanbul, Turkiye
[7] Baskent Univ, Konya Applicat & Res Ctr, Orthoped & Traumatol, Konya, Turkiye
[8] Kastamonu Training & Res Hosp, Kastamonu, Turkiye
关键词
Intramedullary nailing; Humerus fractures; Plate screw system; Finite element analysis; FIXATION; BONE;
D O I
10.1016/j.jor.2023.10.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: This study aims to examine the commonly used plate screw system and intramedullary nailing method in osteosynthesis in humeral shaft fractures in terms of stress shielding using finite element analysis. Material and methods: Images were obtained by computerized tomography (CT) to create a 3D model of the humerus bone. After the CT images were transferred to the ANSYS 2021 R2 program (ANSYS, Inc., Canons-burg, PA), a transverse fracture model was created from the shaft region of the humeral bone meshed to the humerus bone and modeled in the 3D environment. Results: The tetrahedron mesh structure was used for the finite element models in our study. The element size was chosen as 3.5 mm for the bone model and 2 mm for the plate and intramedullary nail models. The node numbers of bone, intramedullary nail, and plate were 91230, 462578, and 581352, respectively. The element numbers of bone, intramedullary nail, and plate were 61350, 311285, and 370350, respectively. Maximum stress values of 260 MPa on the nail and 280 MPa on the plate were detected in this study. Conclusion: Fewer stress values were obtained and stress concentrations were not formed on the implant in osteosynthesis performed by intramedullary nailing. It can be concluded that this study may guide further studies for those focusing on it and may contribute to the development of a more comprehensive understanding of the topic.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [1] Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation
    Hessmann, MH
    Hansen, WSM
    Krummenauer, F
    Pol, TF
    Rommens, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (06): : 1194 - 1201
  • [2] Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures
    Chen, Fancheng
    Huang, Xiaowei
    Ya, Yingsun
    Ma, Fenfen
    Qian, Zhi
    Shi, Jifei
    Guo, Shuolei
    Yu, Baoqing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [3] Finite element analysis of intramedullary nailing and nail-plate combinations for treating unstable proximal tibial metaphyseal fractures
    Toksoy, Sefa
    Demirtas, Idris
    Gungorurler, Musa
    Oztuna, Volkan
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2024, 30 (12): : 861 - 867
  • [4] Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures
    Fancheng Chen
    Xiaowei Huang
    Yingsun Ya
    Fenfen Ma
    Zhi Qian
    Jifei Shi
    Shuolei Guo
    Baoqing Yu
    Journal of Orthopaedic Surgery and Research, 13
  • [5] Design of a novel lateral mass screw-plate system for the treatment of unstable atlas fractures: a finite element analysis
    Niu, He-Gang
    Zhang, Jing-Jing
    Yan, Yi-Zhu
    Zhao, Cheng-Kun
    Yang, Kun
    Zhang, Yin-Shun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [6] Mechanical stability study of three techniques used in the fixation of transverse and oblique metaphyseal-diaphyseal junction fractures of the distal humerus in children: a finite element analysis
    Liu, Chuang
    Kamara, Allieu
    Liu, Tianjing
    Yan, Yunhui
    Wang, Enbo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [7] Mechanical stability study of three techniques used in the fixation of transverse and oblique metaphyseal-diaphyseal junction fractures of the distal humerus in children: a finite element analysis
    Chuang Liu
    Allieu Kamara
    Tianjing Liu
    Yunhui Yan
    Enbo Wang
    Journal of Orthopaedic Surgery and Research, 15
  • [8] Novel screw-cable integrated system(SCIS) for minimally invasive treatment of patella transverse fractures: a finite element analysis
    Liu, Songyang
    Liu, Shen
    Gu, Feng
    Wei, Xing
    Liang, Yonghui
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [9] Effect of Calcar Screw in Locking Compression Plate System for Osteoporotic Proximal Humerus Fracture: A Finite Element Analysis Study
    Lee, Jung-Soo
    Kim, Jong Hoon
    Kim, Kwang Gi
    Yoon, Yong-Cheol
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [10] Biomechanical evaluation of intramedullary retrograde nail and dynamic condylar screw used in unstable distal femoral fractures
    Dizdar, Ayberk
    Celik, Talip
    Ozkan, Arif
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (04) : 1755 - 1764