Development and validation of an LC-MS/MS method for the detection of sodium pentachlorophenolate residues on cutting boards

被引:1
作者
Liao, Shicheng [1 ]
Xu, Wanna [2 ]
Jiang, Jie [1 ]
Liu, Honghe [1 ]
Zeng, Zhuoying [1 ]
机构
[1] Shenzhen Ctr Dis Control & Prevent, Chem Anal & Phys Testing Inst, Shenzhen 518055, Peoples R China
[2] Shenzhen Ctr Chron Dis Control, Shenzhen, Peoples R China
关键词
Sodium pentachlorophenolate; UPLC-MS/MS; solid-phase extraction; food safety; cutting boards; method validation; TANDEM MASS-SPECTROMETRY; FOOD;
D O I
10.1177/00368504241300638
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Objectives The objective of this study was to develop and validate an automated solid-phase extraction (SPE) coupled with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the detection of sodium pentachlorophenolate (PCP-Na) residues on cutting boards. Given the potential hazards and environmental persistence of PCP-Na, a sensitive and reliable method is crucial for monitoring its residues in food contact materials to ensure consumer safety.Methods Wood shavings from cutting boards were extracted using 10% methanol in water, followed by purification using an automated SPE system. The eluent was concentrated, reconstituted, and analyzed by UPLC-MS/MS. An isotope-labeled internal standard was used to mitigate matrix effects, enhancing detection sensitivity. The method was validated by assessing linearity, limit of detection (LOD), limit of quantification (LOQ), recovery rates, and relative standard deviations (RSDs) across various concentration levels.Results The method demonstrated excellent linearity over a concentration range of 0 to 100 mu g/L with a regression equation of Y = 1.035X-0.7771 and an R-2 of 0.9996. The LOD and LOQ were determined to be 0.4 and 1.0 mu g/kg, respectively. Recovery rates ranged from 71.75% to 96.50% with RSDs between 5.19% and 16.66%. When applied to 30 market cutting board samples, PCP-Na residues were detected in 50% of the samples, with concentrations ranging from 0 to 83,990 mu g/kg.Conclusion This study presents a robust UPLC-MS/MS method for the detection of PCP-Na on cutting boards, offering improved sensitivity and simplified sample preparation. The high detection rate in commercial samples underscores the need for stringent monitoring and regulatory measures to mitigate the exposure risk to consumers.
引用
收藏
页数:11
相关论文
共 15 条
[1]   Advances in LC-MS/MS analysis of environmental and food samples [J].
Barcelo, Damia ;
Petrovic, Mira .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (15) :4227-4228
[2]  
Changotra R., 2024, Chemosphere, V352
[3]  
Dorsey Waneene C, 2004, Int J Environ Res Public Health, V1, P90, DOI 10.3390/ijerph2004020090
[4]   Simultaneous Determination of Sodium Pentachlorophenolate and Its Metabolites in Swine Samples [J].
Jia, Qi ;
Cui, Miao ;
Li, Meiling ;
Li, Yuncheng ;
Meng, Fanbing ;
Xu, Yanyang ;
Qian, Yongzhong ;
Yan, Xue ;
Qiu, Jing .
SEPARATIONS, 2023, 10 (10)
[5]   Pentachlorophenol-induced cytotoxicity in human erythrocytes: enhanced generation of ROS and RNS, lowered antioxidant power, inhibition of glucose metabolism, and morphological changes [J].
Maheshwari, Nikhil ;
Khan, Fahim Halim ;
Mahmood, Riaz .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (13) :12985-13001
[6]   On-line solid-phase extraction of pharmaceutical compounds from wastewater treatment plant samples using restricted access media in column-switching liquid chromatography-tandem mass spectrometry [J].
Marasco Junior, Cesar A. ;
Sartore, Douglas M. ;
Lamarca, Rafaela S. ;
da Silva, Bianca F. ;
Santos-Neto, Alvaro J. ;
Gomes, Paulo Clairmont F. de Lima .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1180
[7]   Comparative field performance of oilborne pentachlorophenol versus the substituted isothiazolone DCOI as wood preservatives [J].
Nicholas, Darrel D. .
INTERNATIONAL WOOD PRODUCTS JOURNAL, 2018, 9 (04) :171-175
[8]   Environmental and food applications of LC-tandem mass spectrometry in pesticide-residue analysis:: An overview [J].
Picó, Y ;
Blasco, C ;
Font, G .
MASS SPECTROMETRY REVIEWS, 2004, 23 (01) :45-85
[9]   PENTACHLOROPHENOL CARCINOGENICITY - EXTRAPOLATION OF RISK FROM MICE TO HUMANS [J].
REIGNER, BG ;
BOIS, FY ;
TOZER, TN .
HUMAN & EXPERIMENTAL TOXICOLOGY, 1993, 12 (03) :215-225
[10]   Determination of sodium nifurstyrenate and nitrovin residues in edible food by liquid chromatography-tandem mass spectrometry after ultrasound-assisted extraction [J].
Tao, Yanfei ;
Yu, Huan ;
Chen, Dongmei ;
Liu, Zhao-Ying ;
Yang, Ding ;
Pan, Yuanhu ;
Wang, Yulian ;
Huang, Lingli ;
Yuan, Zonghui .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (32) :3415-3420