Non-enzymatic electrochemical sensors for point-of-care testing: Current status, challenges, and future prospects

被引:2
作者
Bruckschlegel, Christoph [1 ]
Fleischmann, Vivien [1 ]
Gajovic-Eichelmann, Nenad [2 ]
Wongkaew, Nongnoot [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[2] Fraunhofer Inst Cell Therapy & Immunol, Branch Bioanalyt & Bioproc, Am Muehlenberg 13, D-14476 Potsdam, Germany
关键词
Non-enzymatic detection; Electrochemical sensors; Nanomaterials; Point-of-care detection; Wearable devices; Onsite detection; ACID CONCENTRATIONS; HYDROGEN-PEROXIDE; GLUCOSE-OXIDATION; ASCORBIC-ACID; URIC-ACID; BLOOD; ELECTRODES; NANOPARTICLES; BIOSENSOR; GRAPHENE;
D O I
10.1016/j.talanta.2025.127850
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Current electrochemical sensors in point-of-care (POC) testing devices rely mainly on enzyme-based sensors owing to superior sensitivity and selectivity. Nevertheless, the poor stability, high reagent cost, complex fabrication methods and requirement of specific operational conditions make their adaptability in real-world applications unfavorable. Non-enzymatic electrochemical sensors are thus developed as they are more robust and cost-effective strategies. The advancement in material science and nanotechnology enables the development of novel non-enzymatic electrodes with favorable analytical performance. However, the developments are yet far from being adopted as viable products. This review therefore aims to gain insight into the field and evaluate the current progress and challenges to eventually propose future research directions. Here, fabrication strategies based on traditional and emerging technology are discussed in the light of analytical performance and costeffectiveness. Moreover, the discussion is given on the pros and cons of non-enzymatic sensors when they are employed with various kinds of sample matrices, i.e., clinical and non-clinical samples, which must be taken into consideration for sensor development. Furthermore, molecular imprinting technology in tackling the selectivity issue is introduced and current progress is provided. Finally, the promising strategies from literature for solving the remaining challenges are included which could facilitate further development of robust POC testing devices based non-enzymatic sensors. We believe that once researchers and technology developers have reached the point where most problems are solved, the non-enzymatic sensors are going to be the robust choice for POC testing in clinical diagnostic, ensuring food safety, monitoring contaminants in environment, and bioprocess control.
引用
收藏
页数:22
相关论文
共 193 条
[1]   Turning Trash into Treasure: Additive Free MXene Sediment Inks for Screen-Printed Micro-Supercapacitors [J].
Abdolhosseinzadeh, Sina ;
Schneider, Rene ;
Verma, Anand ;
Heier, Jakob ;
Nuesch, Frank ;
Zhang, Chuanfang .
ADVANCED MATERIALS, 2020, 32 (17)
[2]   Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions [J].
Adeel, Muhammad ;
Rahman, Md Mahbubur ;
Caligiuri, Isabella ;
Canzonieri, Vincenzo ;
Rizzolio, Flavio ;
Daniele, Salvatore .
BIOSENSORS & BIOELECTRONICS, 2020, 165
[3]   Nanohybrid electrocatalyst based on cobalt phthalocyanine-carbon nanotube-reduced graphene oxide for ultrasensitive detection of glucose in human saliva [J].
Adeniyi, Omotayo ;
Nwahara, Nnamdi ;
Mwanza, Daniel ;
Nyokong, Tebello ;
Mashazi, Philani .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 348
[4]   Molecularly Imprinted Polymers in Electrochemical and Optical Sensors [J].
Ahmad, Omar S. ;
Bedwell, Thomas S. ;
Esen, Cem ;
Garcia-Cruz, Alvaro ;
Piletsky, Sergey A. .
TRENDS IN BIOTECHNOLOGY, 2019, 37 (03) :294-309
[5]   Wide Linear-Range Detecting Nonenzymatic Glucose Biosensor Based on CuO Nanoparticles Inkjet-Printed on Electrodes [J].
Ahmad, Rafiq ;
Vaseem, Mohammad ;
Tripathy, Nirmalya ;
Hahn, Yoon-Bong .
ANALYTICAL CHEMISTRY, 2013, 85 (21) :10448-10454
[6]   Molecularly Imprinted Polymer-Amyloid Fibril-Based Electrochemical Biosensor for Ultrasensitive Detection of Tryptophan [J].
Alam, Ibrar ;
Lertanantawong, Benchaporn ;
Sutthibutpong, Thana ;
Punnakitikashem, Primana ;
Asanithi, Piyapong .
BIOSENSORS-BASEL, 2022, 12 (05)
[7]   Modified electrode decorated with silver as a novel non-enzymatic sensor for the determination of ammonium in water [J].
Altahan, Mahmoud Fatehy ;
Ali, Asmaa Galal ;
Hathoot, Abla Ahmed ;
Azzem, Magdi Abdel .
SCIENTIFIC REPORTS, 2023, 13 (01)
[8]  
[Anonymous], Facts and figures
[9]   Screen-Printed Electrodes Modified with Metal Nanoparticles for Small Molecule Sensing [J].
Antuna-Jimenez, Daniel ;
Gonzalez-Garcia, Maria Begona ;
Hernandez-Santos, David ;
Fanjul-Bolado, Pablo .
BIOSENSORS-BASEL, 2020, 10 (02)
[10]   Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor [J].
Arakawa, Takahiro ;
Kuroki, Yusuke ;
Nitta, Hiroki ;
Chouhan, Prem ;
Toma, Koji ;
Sawada, Shin-ichi ;
Takeuchi, Shuhei ;
Sekita, Toshiaki ;
Akiyoshi, Kazunari ;
Minakuchi, Shunsuke ;
Mitsubayashi, Kohji .
BIOSENSORS & BIOELECTRONICS, 2016, 84 :106-111