TCAD simulation of the electrical properties of a novel meander strip electrode pixel High-Purity Germanium detector

被引:0
|
作者
Wang, Mingyang [1 ]
Liu, Manwen [3 ]
Zhao, Jun [2 ]
Long, Tao [2 ]
Xiong, Bo [1 ]
Li, Zheng [1 ,2 ]
Xiao, Yongguang [1 ]
机构
[1] Xiangtan Univ, Sch Mat Sci & Engn, Xiangtan 411105, Peoples R China
[2] Ludong Univ, Coll Integrated Circuits, Yantai 264025, Peoples R China
[3] Chinese Acad Sci, Inst Microelect, Beijing 100029, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2025年 / 20卷 / 03期
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Detector modelling and simulations II (electric fields; charge transport; multiplication and induction; pulse formation; electron emission; etc); Solid state detectors;
D O I
10.1088/1748-0221/20/03/P03005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High-purity germanium (HPGe) detectors, serving as crucial devices that convert radiation signals into electrical signals, are characterized by their wide detection range and high energy resolution, which makes them widely applicable in fields such as nuclear physics research and aerospace. HPGe detectors require a large sensitive area thickness to achieve a broad energy detection range. However, the incomplete charge collection becomes more pronounced due to the large size of HPGe detectors. Furthermore, the limited position resolution of large-size detectors greatly hinders the advancement of HPGe detectors. To improve the electrical performance of HPGe detectors in radiation detection applications, this study introduces a new strategy. By designing HPGe detectors as small-size pixel units with meander strip electrodes, we shorten the distance between the cathode and anode. Integrating multiple such units into a detector array enables the detector to improve position resolution capability. The electrical performance of this detector structure was simulated using the semiconductor device simulation software Sentaurus TCAD, and the heavy ions incidence process on the detector array was also modeled. The simulation results consistently indicate that the pixel HPGe detector with meander strip electrode exhibits good electrical performance, charge collection efficiency, and fast response time. Compared to the coaxial HPGe detector with a diameter of 50 mm reported in previous literature, which has a depletion voltage of 1800 V, the pixelated HPGe detector proposed in this paper features a significantly lower full depletion voltage, with a value of -5 V. This study offers a novel approach to enhancing the performance of HPGe detectors and broadens their application scenarios.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] High-precision efficiency calibration of a high-purity co-axial germanium detector
    Blank, B.
    Souin, J.
    Ascher, P.
    Audirac, L.
    Canchel, G.
    Gerbaux, M.
    Grevy, S.
    Giovinazzo, J.
    Guerin, H.
    Nieto, T. Kurtukian
    Matea, I.
    Bouzomita, H.
    Delahaye, P.
    Grinyer, G. F.
    Thomas, J. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 776 : 34 - 44
  • [42] Designing novel organogermanium OMVPE precursors for high-purity germanium films
    Woelk, E
    Shenai-Khatkhate, DV
    DiCarlo, RL
    Amamchyan, A
    Power, MB
    Lamare, B
    Beaudoin, G
    Sagnes, I
    JOURNAL OF CRYSTAL GROWTH, 2006, 287 (02) : 684 - 687
  • [43] STATUS OF A PULSED-NEUTRON LOGGING PROBE USING A HIGH-PURITY GERMANIUM DETECTOR
    JENSEN, DH
    BARNARD, RW
    BIVENS, HM
    HUMPHREYS, DR
    WEINLEIN, JH
    STEPHENSON, WA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1657 - 1663
  • [44] High-purity germanium detector ionization pulse shapes of nuclear recoils, γ-interactions and microphonism
    Baudis, L
    Hellmig, J
    Klapdor-Kleingrothaus, HV
    Ramachers, Y
    Hammer, JW
    Mayer, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 348 - 354
  • [45] DISLOCATIONS IN HIGH-PURITY GERMANIUM AND ITS RELATION TO GAMMA-RAY DETECTOR PERFORMANCE
    VANSANDE, M
    VANGOETHEM, L
    DELAET, L
    GUISLAIN, H
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1986, 40 (04): : 257 - 261
  • [46] Application of high-purity germanium (HPGe) detector to advanced laboratory experiment on the Compton effect
    Hieronymus, SA
    Lundquist, LL
    Cornell, DA
    AMERICAN JOURNAL OF PHYSICS, 1998, 66 (09) : 836 - 836
  • [47] MEASUREMENT OF THE DEAD-LAYER THICKNESS OF A PLANAR INTRINSIC HIGH-PURITY GERMANIUM DETECTOR
    PESSARA, W
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (02): : 519 - 520
  • [48] 2-DETECTOR, 512-ELEMENT HIGH-PURITY GERMANIUM CAMERA PROTOTYPE
    KAUFMAN, L
    LORENZ, V
    HOSIER, K
    HOENNINGER, J
    HATTNER, RS
    OKERLUND, M
    PRICE, DC
    SHAMES, DM
    SWANN, SJ
    EWINS, JH
    ARMANTROUT, GA
    CAMP, DC
    LEE, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 189 - 195
  • [49] High-purity germanium detector ionization pulse shapes of nuclear recoils, γ-interactions and microphonism
    Baudis, L.
    Hellmig, J.
    Klapdor-Kleingrothaus, H.V.
    Ramachers, Y.
    Hammer, J.W.
    Mayer, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 418 (2-3): : 348 - 354
  • [50] A novel virtual point detector model for high purity germanium detectors
    Stanga, D.
    Gurau, D.
    Done, L.
    Luca, A.
    APPLIED RADIATION AND ISOTOPES, 2022, 181