TCAD simulation of the electrical properties of a novel meander strip electrode pixel High-Purity Germanium detector

被引:0
|
作者
Wang, Mingyang [1 ]
Liu, Manwen [3 ]
Zhao, Jun [2 ]
Long, Tao [2 ]
Xiong, Bo [1 ]
Li, Zheng [1 ,2 ]
Xiao, Yongguang [1 ]
机构
[1] Xiangtan Univ, Sch Mat Sci & Engn, Xiangtan 411105, Peoples R China
[2] Ludong Univ, Coll Integrated Circuits, Yantai 264025, Peoples R China
[3] Chinese Acad Sci, Inst Microelect, Beijing 100029, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2025年 / 20卷 / 03期
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Detector modelling and simulations II (electric fields; charge transport; multiplication and induction; pulse formation; electron emission; etc); Solid state detectors;
D O I
10.1088/1748-0221/20/03/P03005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High-purity germanium (HPGe) detectors, serving as crucial devices that convert radiation signals into electrical signals, are characterized by their wide detection range and high energy resolution, which makes them widely applicable in fields such as nuclear physics research and aerospace. HPGe detectors require a large sensitive area thickness to achieve a broad energy detection range. However, the incomplete charge collection becomes more pronounced due to the large size of HPGe detectors. Furthermore, the limited position resolution of large-size detectors greatly hinders the advancement of HPGe detectors. To improve the electrical performance of HPGe detectors in radiation detection applications, this study introduces a new strategy. By designing HPGe detectors as small-size pixel units with meander strip electrodes, we shorten the distance between the cathode and anode. Integrating multiple such units into a detector array enables the detector to improve position resolution capability. The electrical performance of this detector structure was simulated using the semiconductor device simulation software Sentaurus TCAD, and the heavy ions incidence process on the detector array was also modeled. The simulation results consistently indicate that the pixel HPGe detector with meander strip electrode exhibits good electrical performance, charge collection efficiency, and fast response time. Compared to the coaxial HPGe detector with a diameter of 50 mm reported in previous literature, which has a depletion voltage of 1800 V, the pixelated HPGe detector proposed in this paper features a significantly lower full depletion voltage, with a value of -5 V. This study offers a novel approach to enhancing the performance of HPGe detectors and broadens their application scenarios.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] TCAD Simulation Study of Electrical Performance of a Novel High-Purity Germanium Drift Detector
    Wang, Mingyang
    Li, Zheng
    Xiong, Bo
    Xiao, Yongguang
    MICROMACHINES, 2025, 16 (02)
  • [2] PROTOTYPE GAMMA CAMERA SYSTEM BASED ON A STRIP-ELECTRODE, HIGH-PURITY GERMANIUM DETECTOR
    MILLER, DW
    SCHLOSSE.PA
    GERBER, MS
    REDMOND, RF
    HUNTER, WW
    JOURNAL OF NUCLEAR MEDICINE, 1974, 15 (06) : 517 - 517
  • [3] CHARACTERISTICS OF A HIGH-PURITY GERMANIUM DETECTOR
    THOMAS, GE
    PEHL, RH
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (01): : 65 - 67
  • [4] HIGH-PURITY GERMANIUM DETECTOR ARRAY
    STONE, RT
    MACOVSKI, A
    BRODY, WR
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 314 : 55 - 61
  • [5] Effect of the microstructure on electrical properties of high-purity germanium
    Podkopaev, O. I.
    Shimanskii, A. F.
    Molotkovskaya, N. O.
    Kulakovskaya, T. V.
    PHYSICS OF THE SOLID STATE, 2013, 55 (05) : 949 - 951
  • [6] Effect of the microstructure on electrical properties of high-purity germanium
    O. I. Podkopaev
    A. F. Shimanskii
    N. O. Molotkovskaya
    T. V. Kulakovskaya
    Physics of the Solid State, 2013, 55 : 949 - 951
  • [7] Mapping the Response of a Double-Sided Strip High-Purity Germanium Detector
    Perea, Rose S.
    Furenlid, Lars
    Shokouhi, Sepideh
    Peterson, Todd E.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [8] TIMING WITH HIGH-PURITY GERMANIUM COAXIAL DETECTOR
    CHO, ZH
    LLACER, J
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (03): : 461 - &
  • [9] Inter-Strip Interpolation Measurements in a High-Purity Germanium Double-Sided Strip Detector
    Hayward, Jason P.
    Wehe, David K.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 800 - 807
  • [10] HIGH-PURITY GERMANIUM - DETECTOR FABRICATION AND PERFORMANCE
    PEHL, RH
    GOULDING, FS
    CORDI, RC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (01) : 265 - +