Piloting an external quality assurance program (QAP) for COVID-19 antigen rapid diagnostic tests (Ag-RDTs): findings and lessons learned from Cambodia

被引:0
作者
Phoeung, Chan Leakhena [1 ]
Prestedge, Jacqueline [2 ]
Ninan, Marilyn [2 ]
Cunningham, Philip [3 ,4 ]
Bory, Sothavireak [5 ]
Seang, Kennarey [6 ]
Heng, Kanika [5 ]
Williamson, Deborah [2 ]
Markby, Jessica [7 ]
Valley, Andrew [3 ]
Kaldor, John [3 ]
Saphonn, Vonthanak [8 ]
机构
[1] Univ Hlth Sci, Phnom Penh, Cambodia
[2] Univ Melbourne, Peter Doherty Inst Infect & Immun, Melbourne, Vic, Australia
[3] Univ New South Wales, Kirby Inst, Sydney, NSW, Australia
[4] St Vincents Hlth Network, Sydney, NSW, Australia
[5] Univ Hlth Sci, Fac Pharm, Phnom Penh, Cambodia
[6] Univ Hlth Sci, Grant Management Off, Phnom Penh, Cambodia
[7] Fdn Innovat New Diagnost, Geneva, Geneve, Switzerland
[8] Univ Hlth Sci, Rectorate, Phnom Penh, Cambodia
关键词
COVID-19; Quality improvement; Performance measures; Health professions education;
D O I
10.1136/bmjoq-2024-002999
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Rapid antigen diagnostic tests (Ag-RDTs) that quickly and accurately identify SARS-CoV-2 are an essential part of the COVID-19 response, but multiple factors can affect the validity of Ag-RDTs results. In Cambodia, several commercial Ag-RDTs have become available since the COVID-19 outbreak, but quality control (QC) and external quality assurance (EQA) of these rapid tests have yet to be fully and systematically implemented. We collaborated with laboratory experts in Australia and piloted an EQA programme of the commonly used COVID-19 Ag-RDTs at the University of Health Sciences' MERIEUX Laboratory (Tier 1 site-responsible for the in-country receipt and distribution of QA material) and four other participating laboratories (Tier 2-healthcare facility based) between November 2021 and November 2022. The preimplementation training including the Khmer-translated documentation was conducted virtually for Tier 1 laboratories and in-person for Tier 2 laboratories. All QC (n=290) and EQA (n=60) specimens were distributed to the laboratories and testing was performed according to the frequency of Ag-RDTs use in each laboratory. All National Reference Laboratory-provided EQA and QC specimens were tested and results were submitted via the EDCNet portal using QR code scanning. The Tier 1 laboratory reported 100% concordance with the EQA reference result, while some of Tier 2 laboratories' results were discordant. While continued capacity building and support with troubleshooting have been key to the successful EQA piloting at the UHS laboratory, the programme experienced delays in the shipping/delivery of EQA and QC panels due to customs and border requirements, which could have hindered implementation and potentially impacted the quality of the QA materials. The pilot EQA programme demonstrated potential scalability and provided data on the reliability of test results at the site. However, to ensure sustainability and practicability of this activity, in-country EQA panel preparation may need to be considered.
引用
收藏
页数:8
相关论文
共 24 条
  • [1] Donoso Mantke O., Corman V.M., Taddei F., Et al., Importance of external quality assessment for SARS-CoV-2 antigen detection during the COVID-19 pandemic, J Clin Virol, 154, (2022)
  • [2] Payne D.A., Russomando G., Linder M.W., Et al., External quality assessment (EQA) and alternative assessment procedures (AAPs) in molecular diagnostics: findings of an international survey, Clin Chem Lab Med, 59, pp. 301-306, (2020)
  • [3] Wang H., Li G., Zhao J., Et al., An Overview of Nucleic Acid Testing for the Novel Coronavirus SARS-CoV-2, Front Med (Lausanne), 7, (2020)
  • [4] Manabe Y.C., Mashalla Y., Farquhar C., Et al., Leadership training to accelerate progress in public health in sub-Saharan Africa: time for action, Lancet Glob Health, 8, pp. e1253-e1254, (2020)
  • [5] Manabe Y.C., Reuland C., Yu T., Et al., Variability of salivary and nasal specimens for sars-cov-2 detection, (2020)
  • [6] Randad P.R., Pisanic N., Kruczynski K., Et al., COVID-19 serology at population scale: SARS-CoV-2-specific antibody responses in saliva, (2020)
  • [7] Dinnes J., Deeks J.J., Adriano A., Et al., Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection, Cochrane Database Syst Rev, 8, (2020)
  • [8] Albert E., Torres I., Bueno F., Et al., Field evaluation of a rapid antigen test (Panbio COVID-19 Ag Rapid Test Device) for COVID-19 diagnosis in primary healthcare centres, Clin Microbiol Infect, 27, (2021)
  • [9] Brummer L.E., Katzenschlager S., Gaeddert M., Et al., Accuracy of novel antigen rapid diagnostics for SARS-CoV-2: A living systematic review and meta-analysis, PLoS Med, 18, (2021)
  • [10] Fleming K.A., Horton S., Wilson M.L., Et al., The Lancet Commission on diagnostics: transforming access to diagnostics, The Lancet, 398, pp. 1997-2050, (2021)