Experimental investigation on the bond performance of a hybrid lap-spliced connection of GFRP and stainless steel bars in concrete

被引:1
作者
Zhou, Jiafeng [1 ]
Zhao, Jitong [2 ]
Peng, Mengyan [1 ]
Liebscher, Marco [2 ]
Mechtcherine, Viktor [2 ]
Marx, Steffen [1 ]
Kang, Chongjie [1 ]
机构
[1] Tech Univ Dresden, Inst Concrete Struct, D-01219 Dresden, Germany
[2] Tech Univ Dresden, Inst Construct Mat, D-01062 Dresden, Germany
关键词
Bond behavior; Lap-spliced connection; GFRP bar; Stainless steel bar; Distributed fiber optical sensor; Microstructural characterization; Strain distribution; REINFORCED POLYMER REBARS; FRP BARS; FIBER; STRENGTH; BEHAVIOR;
D O I
10.1016/j.cemconcomp.2025.105952
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the bond performance of a hybrid lap-spliced connection of glass fiber reinforced polymer (GFRP) bars and stainless steel bars in concrete. To gain a comprehensive understanding, micro-level and macrolevel mechanical studies are conducted. First, the microstructural characterization of GFRP bars is performed to comprehend the specific material features. Then, cantilever tests are conducted to identify the optimal direction of bar grooves, which is pre-cut by a machine, and to place the distributed fiber optical sensor (DFOS). Subsequently, four-point flexural tests are carried out on eight large-scale specimens to investigate the influence of lapspliced length and type on the specimen responses. The DFOSs are employed in the grooves of lap-spliced GFRP and stainless steel bars to characterize their bond behaviors. The findings indicate a significant enhancement in load capacity, with an increase of approximately 10 kN for every 100 mm increase in the lap-spliced length. Furthermore, the incorporation of a hybrid connection, combining GFRP and stainless steel bars, demonstrates a slight improvement of 5 kN in load capacity over the pure lap-spliced connection of stainless steel bars. Additionally, detailed investigations are conducted on the strain distributions in the lap-spliced bars.
引用
收藏
页数:18
相关论文
共 59 条
[1]  
ACI Committee, 2015, ACI 4401 R 15 GUIDE, DOI DOI 10.1061/40753(171)158
[2]   Bond performances of FRP rebars-reinforced concrete [J].
Aiello, Maria Antonietta ;
Leone, Marianovella ;
Pecce, Marisa .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2007, 19 (03) :205-213
[3]  
Aly R, 2006, ACI STRUCT J, V103, P857
[4]   Tensile lap splicing of bundled CFRP reinforcing bars in concrete [J].
Aly, Ragi ;
Benmokrane, Brahim ;
Ebead, Usama .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (04) :287-294
[5]  
[Anonymous], 2009, 68921 ISO
[6]  
[Anonymous], 2009, DIN EN 12390-5
[7]  
[Anonymous], 2009, DIN EN 12390-6
[8]  
[Anonymous], 2000, Bulletin dInformation de la Federation Internationale du Beton, n, P10
[9]  
[Anonymous], 2019, DIN EN 12390-3
[10]  
[Anonymous], 2003, ACI Technical Document, P1