Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults

被引:0
|
作者
Said, Abdelrahman [1 ,2 ]
Galal, Mohamed [1 ]
Abd-Allah, M. A. [1 ]
机构
[1] Benha Univ, Fac Engn Shoubra, Dept Elect Engn, Cairo, Egypt
[2] Benha Natl Univ BNU, Fac Comp Sci, Al Obour, Egypt
来源
PLOS ONE | 2024年 / 19卷 / 12期
关键词
D O I
10.1371/journal.pone.0313229
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
HVDC systems with high voltage and direct current are suitable for reducing electricity losses, during transmission over long distances. However, HVDC lines have the highest probability of failure within a system and can be damaged by different faults or lightning strikes. This paper presents a transient circuit model for the practical Egypt-Saudi Arabia link. The transient potential at different points along the line is calculated under different magnitudes and shapes of lightning strokes. "Additionally, the extent of transient overvoltages at the rectifier station due to shifts in lightning strike locations has been estimated. Furthermore, overvoltage distributions are examined caused by lightning strikes on a real +/- 500 kV hybrid HVDC TL-Cableare examined. To prevent national disasters and maintain safe national ratios of electrical production, particularly in the case of hybrid HVDC TL-Cable faults, an analysis of different AC/DC faults in the hybrid HVDC TL-Cable is also presented. This study is based on an equivalent electrical model using Power Systems Computer-Aided Design (PSCAD) software. It was discovered that severe voltages appear at the rectifier station when 50 kAlightning stroke with 1.2 mu sec front time, and 350 mu sectail time hits the TL. Moreover, overvoltages are reduced by about 58% in hybrid HVDC TL-Cable. Also, surge arresters at rectifier stations reduce overvoltages by approximately 95%. Ultimately, DC pole-to-ground faults are more serious than other types of faults and can cause massive overcurrent in the system, potentially damaging the rectifier station.
引用
收藏
页数:21
相关论文
共 16 条
  • [1] Assessment of Overvoltage and Insulation Coordination in Mixed HVDC Transmission Lines Exposed to Lightning Strikes
    Asif, Mansoor
    Lee, Ho-Yun
    Park, Kyu-Hoon
    Shakeel, Ayesha
    Lee, Bang-Wook
    ENERGIES, 2019, 12 (21)
  • [2] Evaluation of the Transient Overvoltages of HVDC Transmission Lines Caused by Lightning Strikes
    Zalhaf, Amr S.
    Zhao, Ensheng
    Han, Yang
    Yang, Ping
    Almaliki, Abdulrazak H.
    Aly, Reda M. H.
    ENERGIES, 2022, 15 (04)
  • [3] ELECTROMAGNETIC INTERFERENCE DUE TO HVDC TRANSMISSION LINE FAULTS
    Yang, Yixin
    Ma, Jinxi
    Fortin, Simon
    Dawalibi, Farid
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [5] Modelling Transient Response of Nonuniform Transmission Lines Due to Nearby Lightning Strikes
    Gunawardana, Manuja
    Kordi, Behzad
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [6] METHOD OF ASSESSMENT OF THE ELECTRIC SHOCK HAZARD DUE TO LIGHTNING.
    Flisowski, Zdobyslaw
    Mazzetti, Carlo
    Archiwum Elektrotechniki, 1985, 34 (3-4): : 591 - 602
  • [7] Modeling of flashover arcs in medium voltage networks due to direct lightning strikes
    Mahmood, Farhan
    Elkalashy, Nagy I.
    Lehtonen, Matti
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 65 : 59 - 69
  • [8] ELECTRICAL INDUCTION ON FENCES DUE TO FAULTS ON ADJACENT HVDC TRANSMISSION-LINES
    MOHAN, N
    MAHJOURI, FS
    GEMAYEL, JR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (08): : 2851 - 2859
  • [9] Assessment of Shielding Performance of 69/138 kV Transmission lines Exposed to Lightning Strikes
    Malcolm, Newman
    Aggarwal, Raj K.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [10] Assessment of induced voltages in common and differential-mode for a PV module due to nearby lightning strikes
    Formisano, Alessandro
    Petrarca, Carlo
    Hernandez, Jesus C.
    Jose Munoz-Rodriguez, Francisco
    IET RENEWABLE POWER GENERATION, 2019, 13 (08) : 1369 - 1378