Comparison of Body Temperature Values Measured With Noncontact Forehead Thermometer and Tympanic Thermometer in Adult Individuals

被引:1
作者
Dogan, Sevgi [1 ]
Avsar, Gulcin [1 ]
机构
[1] Ataturk Univ, Fac Nursing, Dept Nursing Fundamentals, Erzurum, Turkiye
关键词
body temperature; nursing; thermometer; forehead thermometer; temperature measurement; INFRARED THERMOMETER; CLINICAL ACCURACY; SKIN TEMPERATURE; AXILLARY;
D O I
10.1891/JNM-2023-0035
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background and Purpose: Noncontact forehead thermometers have become increasingly widespread because of their advantages, such as rapid measurement of temperature, noninvasiveness, ease of use, and portability. The aim of the study was to compare the body temperature values measured using a noncontact forehead thermometer and a tympanic thermometer. Methods: A cross-sectional, comparative, and quasi-experimental research design was used in this study. The research population was composed of 200 adult individuals older than 18 years who were being treated at the hospital between January 2015 and March 2015. The temperature and humidity of the environment were measured with an electronic thermo-hygrometer thermometer. The body temperature of the patient was measured with both a noncontact forehead thermometer and a tympanic thermometer by the same researcher. The data were recorded in the patient information form and the patient observation form. Results: Mean body temperature values measured with a noncontact forehead thermometer and a tympanic thermometer were 36.17 degrees C +/- 0.47 degrees C and 36.89 degrees C +/- 0.44 degrees C, respectively. Results showed that there was no clear relationship between differences and averages, and there was conformity between the two methods. Conclusions: The mean forehead temperature is lower than the tympanic temperature, and there is conformity between the two methods.
引用
收藏
页码:504 / 514
页数:11
相关论文
共 45 条
[1]  
Apa H, 2013, PEDIATR EMERG CARE, V29, P992, DOI 10.1097/PEC.0b013e3182a2d419
[2]  
Asti T. A., 2019, HemsIrelik esaslari hemsirelik bilim ve sanati, P496
[3]   Comparison of three different thermometers in evaluating the body temperature of healthy young adult individuals [J].
Basak, Tulay ;
Aciksoz, Semra ;
Tosun, Betul ;
Akyuz, Aygul ;
Acikel, Cengizhan .
INTERNATIONAL JOURNAL OF NURSING PRACTICE, 2013, 19 (05) :471-478
[4]   Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer [J].
Bayhan, Cihangul ;
Ozsurekci, Yasemin ;
Tekcam, Necmiye ;
Guloglu, Ayse ;
Ehliz, Gulten ;
Ceyhan, Mehmet ;
Kara, Ates .
JOURNAL OF PEDIATRIC INFECTION, 2014, 8 (02) :52-55
[5]  
Berksoy EA, 2018, INT J CLIN EXP MED, V11, P567
[6]   Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients [J].
Can, Emrah ;
Bulbul, Ali ;
Uslu, Sinan ;
Nuhoglu, Asiye .
TURK PEDIATRI ARSIVI-TURKISH ARCHIVES OF PEDIATRICS, 2010, 45 (03) :257-263
[7]   Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites [J].
Chen, Hsuan-Yu ;
Chen, Andrew ;
Chen, Chiachung .
SENSORS, 2020, 20 (10)
[8]  
Craven R., 2013, FUNDAMENTALS NURSING, V7th
[9]   Evaluating the Interchangeability of Forehead, Tympanic, and Axillary Thermometers in Italian Paediatric Clinical Settings: Results of a Multicentre Observational Study [J].
Dante, Angelo ;
Franconi, Ilaria ;
Marucci, Anna Rita ;
Alfes, Celeste M. ;
Lancia, Loreto .
JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES, 2020, 52 :E21-E25
[10]  
Davie A, 2010, Nurs Stand, V24, P42