Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research

被引:0
作者
Nang, Vo Sy Quyen [1 ,2 ,3 ]
Hieu, Pham Trung [3 ]
Nam, Vu Tu [3 ]
Dung, Tran Trung [2 ,3 ]
Toan, Duong Dinh [1 ]
机构
[1] Hanoi Med Univ, Hanoi, Vietnam
[2] Vinmec Healthcare Syst, Ctr Orthopaed & Sport Med, Hanoi, Vietnam
[3] VinUniversity, 3D Technol Med Ctr, Hanoi, Vietnam
关键词
3D printing; Total knee arthroplasty; TKA; In-hospital 3D printing; Patient-specific instrumentation; PSI; ROTATIONAL ALIGNMENT; TIBIAL COMPONENT; PAIN;
D O I
10.1016/j.jor.2024.10.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient-specific instruments (PSIs) were reported to improve implant position and rotation accuracy in total knee arthroplasty (TKA), among other benefits. Most PSIs used in TKA were commercial products from implant manufacturers, which could be time-consuming and could potentially affect accuracy as they relied on engineer's decision. This study aimed to present the radiological outcomes of PSI produced by the 3D printing facility at our hospital, with direct involvement of the surgeon in its design. Methods: This prospective study enrolled 45 patients who underwent mechanically aligned TKA. Preoperative whole-limb 3D-CT scans were obtained to create the sizing plan. The surgeon identified the position of the cut plane and guide pin locations on software, which were then forwarded to engineers for further processing. Subsequently, the PSI was fabricated using in-hospital 3D resin printers. During surgery, after removing all remaining cartilage, the PSI was utilized on the bone surfaces to assist surgeons in drilling pinhole positions for the manufacturer's cutting instruments. Post-surgery, CT scans were acquired and overlaid onto the 3D model of the implant to compare to the plan. Results: On average, it took three days to prepare for the surgery using PSI. 100 % of patients had implant sizes that matched the preconception template. The mean postoperative hip-knee angle was 178.1 degrees f 1.34 degrees. The mean femoral component rotation angle relative to the surgical transepicondylar axis (sTEA) and the mean rotation mismatch between the femur and tibial component were 0.99 degrees f 0.84 degrees and 0.91 degrees f 1.61 degrees, respectively. Conclusions: Preliminary radiological results demonstrated that in-hospital PSI was a useful technique for improving the accuracy of implant positioning in TKA, especially in controlling the rotational alignment.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 20 条
  • [11] Patient specific instrumentation in total knee arthroplasty: a state of the art
    Mattei, Lorenzo
    Pellegrino, Pietro
    Calo, Michel
    Bistolfi, Alessandro
    Castoldi, Filippo
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (07)
  • [12] Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty
    Michaut, M.
    Beaufils, P.
    Galaud, B.
    Abadie, P.
    Boisrenoult, P.
    Fallet, L.
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (06): : 580 - 584
  • [13] Rotational alignment of the tibial component affects the kinematic rotation of a weight-bearing knee after total knee arthroplasty
    Nakahara, Hiroyuki
    Okazaki, Ken
    Hamai, Satoshi
    Kawahara, Shinya
    Higaki, Hidehiko
    Mizu-uchi, Hideki
    Iwamoto, Yukihide
    [J]. KNEE, 2015, 22 (03) : 201 - 205
  • [14] Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA
    Ng, Vincent Y.
    DeClaire, Jeffrey H.
    Berend, Keith R.
    Gulick, Bethany C.
    Lombardi, Adolph V., Jr.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) : 99 - 107
  • [15] Internal rotational error of the tibial component is a major cause of pain after total knee replacement
    Nicoll, D.
    Rowley, D. I.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (09): : 1238 - 1244
  • [16] Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement: A computer simulation study
    Piazza, SJ
    Delp, SL
    Stulberg, SD
    Stern, SH
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (02) : 264 - 270
  • [17] Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved
    Sassoon, Adam
    Nam, Denis
    Nunley, Ryan
    Barrack, Robert
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (01) : 151 - 158
  • [18] Anatomical references for tibial sagittal alignment in total knee arthroplasty: A comparison of three anatomical axes based on 3D reconstructed CT images
    Shao Jun-jie
    Vail, Thomas Parker
    Wang Qiao-jie
    Shen Hao
    Chen Yun-su
    Wang, Qi
    Jiang Yao
    Zhang Xian-long
    [J]. CHINESE MEDICAL JOURNAL, 2013, 126 (20) : 3840 - 3844
  • [19] Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component
    Sotozawa, Masaichi
    Kumagai, Ken
    Yamada, Shunsuke
    Nejima, Shuntaro
    Inaba, Yutaka
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [20] Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis
    Tibesku, Carsten O. O.
    Haas, Steven B. B.
    Saunders, Christopher
    Harwood, David A. A.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4379 - 4393