Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research

被引:0
作者
Nang, Vo Sy Quyen [1 ,2 ,3 ]
Hieu, Pham Trung [3 ]
Nam, Vu Tu [3 ]
Dung, Tran Trung [2 ,3 ]
Toan, Duong Dinh [1 ]
机构
[1] Hanoi Med Univ, Hanoi, Vietnam
[2] Vinmec Healthcare Syst, Ctr Orthopaed & Sport Med, Hanoi, Vietnam
[3] VinUniversity, 3D Technol Med Ctr, Hanoi, Vietnam
关键词
3D printing; Total knee arthroplasty; TKA; In-hospital 3D printing; Patient-specific instrumentation; PSI; ROTATIONAL ALIGNMENT; TIBIAL COMPONENT; PAIN;
D O I
10.1016/j.jor.2024.10.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient-specific instruments (PSIs) were reported to improve implant position and rotation accuracy in total knee arthroplasty (TKA), among other benefits. Most PSIs used in TKA were commercial products from implant manufacturers, which could be time-consuming and could potentially affect accuracy as they relied on engineer's decision. This study aimed to present the radiological outcomes of PSI produced by the 3D printing facility at our hospital, with direct involvement of the surgeon in its design. Methods: This prospective study enrolled 45 patients who underwent mechanically aligned TKA. Preoperative whole-limb 3D-CT scans were obtained to create the sizing plan. The surgeon identified the position of the cut plane and guide pin locations on software, which were then forwarded to engineers for further processing. Subsequently, the PSI was fabricated using in-hospital 3D resin printers. During surgery, after removing all remaining cartilage, the PSI was utilized on the bone surfaces to assist surgeons in drilling pinhole positions for the manufacturer's cutting instruments. Post-surgery, CT scans were acquired and overlaid onto the 3D model of the implant to compare to the plan. Results: On average, it took three days to prepare for the surgery using PSI. 100 % of patients had implant sizes that matched the preconception template. The mean postoperative hip-knee angle was 178.1 degrees f 1.34 degrees. The mean femoral component rotation angle relative to the surgical transepicondylar axis (sTEA) and the mean rotation mismatch between the femur and tibial component were 0.99 degrees f 0.84 degrees and 0.91 degrees f 1.61 degrees, respectively. Conclusions: Preliminary radiological results demonstrated that in-hospital PSI was a useful technique for improving the accuracy of implant positioning in TKA, especially in controlling the rotational alignment.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 20 条
  • [1] Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
  • [2] The influence of tibial slope on maximal flexion after total knee arthroplasty
    Bellemans, J
    Robijns, F
    Duerinckx, J
    Banks, S
    Vandenneucker, H
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) : 193 - 196
  • [3] Malrotation causing patellofemoral complications after total knee arthroplasty
    Berger, RA
    Crossett, LS
    Jacobs, JJ
    Rubash, HE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) : 144 - 153
  • [4] Patient-specific instrumentation for total knee arthroplasty: a literature review
    Camarda L.
    D’Arienzo A.
    Morello S.
    Peri G.
    Valentino B.
    D’Arienzo M.
    [J]. MUSCULOSKELETAL SURGERY, 2015, 99 (1) : 11 - 18
  • [5] The effect of posterior tibial slope on anteroposterior stability in posterior cruciate retaining total knee arthroplasty
    Ersin, Mehmet
    Demirel, Mehmet
    Civan, Melih
    Ekinci, Mehmet
    Akgul, Turgut
    Sen, Cengiz
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [6] 2D versus 3D templating in total knee arthroplasty
    Ettinger, Max
    Claassen, Leif
    Paes, Peter
    Calliess, Tilman
    [J]. KNEE, 2016, 23 (01) : 149 - 151
  • [7] Do patient-specific instruments (PSI) for UKA allow non-expert surgeons to achieve the same saw cut accuracy as expert surgeons?
    Jones, Gareth G.
    Logishetty, K.
    Clarke, S.
    Collins, R.
    Jaere, M.
    Harris, S.
    Cobb, J. P.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (11) : 1601 - 1608
  • [8] Navigation and robotics improved alignment compared with PSI and conventional instrument, while clinical outcomes were similar in TKA: a network meta-analysis
    Lei, Kai
    Liu, LiMing
    Chen, Xin
    Feng, Qing
    Yang, Liu
    Guo, Lin
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (02) : 721 - 733
  • [9] Favourable rotational alignment outcomes in PSI knee arthroplasty: A Level 1 systematic review and meta-analysis
    Mannan, A.
    Smith, T. O.
    [J]. KNEE, 2016, 23 (02) : 186 - 190
  • [10] Coronal alignment in total knee arthroplasty: a review
    Matassi, F.
    Pettinari, F.
    Frascona, F.
    Innocenti, M.
    Civinini, R.
    [J]. JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 24 (01)