Comparative evaluation of hematological parameters and instrument performance in single and double plateletpheresis procedures using Haemonetics MCS plus and Trima Accel systems

被引:0
作者
Babaahmadi, Niloufar Kazemi [1 ]
Kheirandish, Maryam [1 ]
Teimourpour, Amir [2 ]
Mohammadi, Saeed [3 ,4 ]
Nazemi, Amir Masoud [2 ]
机构
[1] Iranian Blood Transfus Org IBTO, High Inst Res & Educ Transfus Med, Blood Transfus Res Ctr, Dept Immunol, Tehran, Iran
[2] High Inst Res & Educ Transfus Med, Blood Transfus Res Ctr, Tehran, Iran
[3] Univ Tehran Med Sci, Cell Therapy & Hematopoiet Stem Cell Transplantat, Tehran, Iran
[4] Univ Tehran Med Sci, Res Inst Oncol Hematol & Cell Therapy, Tehran, Iran
关键词
Plateletpheresis; Platelet Transfusions; Blood Donation; Haemonetics MCS plus; Trima Accel; Hematological Parameters; Instrument Performance; DOUBLE DOSE PLATELETPHERESIS; BACTERIAL-CONTAMINATION; TRANSFUSION REACTIONS; APHERESIS PLATELETS; WHOLE-BLOOD; COUNT;
D O I
10.1016/j.tracli.2024.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Plateletpheresis (PP) has become increasingly prevalent due to its cost-effectiveness and fewer immunological and infectious complications for recipients. This study compares hematological indices of platelet donors and instrument-related parameters in high-yield PP donors using Haemonetics MCS+ and Trima Accel. Methods: Eligible and healthy PP donors meeting the platelet donation criteria were randomly selected.19 single-dose platelet (SDP), and 26 double-dose platelet (DDP) donors underwent PP using the Haemonetics MCS+, while 21 SDP and 21 DDP donors were processed using the Trima Accel system. Complete Blood Count (CBC) and hematological indices of donors between groups with both devices were measured with the cell counter. Platelet yield, collection efficiency (CE), and collection rate (CR) were evaluated for both devices. Results were reported using R-4.3.2 software and a p-value <0.05 was considered statistically significant. Results: The Trima Accel processed significantly more blood volume and had shorter procedure times than MCS+. Platelet yield in the SDP group with Trima Accel was significantly higher than the Haemonetics MCS+. The Trima Accel demonstrated a significantly higher CR and CE than the MCS+ in both SDP and DDP groups. Post-PP lymphocyte counts significantly decreased with the Trima compared to the MCS+ in the SDP group. However, post-PP hematocrit (HCT), mean corpuscular volume (MCV), and mean platelet volume (MPV) in the DDP group with the MCS+ were significantly lower than Trima. Conclusion: Double-dose plateletpheresis (DDP) offers advantages in cost-effectiveness and platelet production, and although it reduces some hematological indices, these remain within normal limits. The Trima Accel may offer superior efficiency and processing times compared to the MCS+. However, careful monitoring of DDP donors following AABB standards remains essential. (c) 2024 Socit francophone de transfusion sanguine (SFTS). Published by Elsevier Masson SAS. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:28 / 38
页数:11
相关论文
共 40 条
[1]  
American Association of Blood Banks, 2006, About us
[2]  
[Anonymous], 2020, Guide to the Preparation, Use and Quality Assurance of Blood Components, V20th
[3]   A comparative study of five plateletpheresis machines in a tertiary care center of India:AmiCOREvsCOM.TECvs HaemoneticsMCS plus vs Spectra Optia vs Trima Accel [J].
Arcot, Priyadarsini Jayachandran ;
Kumar, Karan ;
Coshic, Poonam ;
Andriyas, Vijay ;
Mehta, Vikas .
JOURNAL OF CLINICAL APHERESIS, 2021, 36 (01) :41-47
[4]   Comparative assessment of single-donor plateletpheresis by Haemonetics® MCS® plus and Trima Accel® [J].
Baruah, Sukanya ;
Bajpai, Meenu .
ASIAN JOURNAL OF TRANSFUSION SCIENCE, 2020, 14 (01) :23-27
[5]   Effect of plateletpheresis on complete blood count values using three different cell separator systems in healthy donors [J].
Beyan, C ;
Çetin, T ;
Kaptan, K ;
Nevruz, O .
TRANSFUSION AND APHERESIS SCIENCE, 2003, 29 (01) :45-47
[6]   Effect of double dose plateletpheresis on target yield and donor platelet recovery [J].
Chopra, Sapna ;
Kaur, Paramjit ;
Bedi, Ravneet Kaur ;
Kaur, Gagandeep .
HEMATOLOGY TRANSFUSION AND CELL THERAPY, 2023, 45 (01) :16-24
[7]  
Cushing MM, 2019, TRANSFUSION MEDICINE AND HEMOSTASIS: CLINICAL AND LABORATORY ASPECTS, 3RD EDITION, P213, DOI 10.1016/B978-0-12-813726-0.00035-0
[8]   Bacterial screening of apheresis platelets and the residual risk of septic transfusion reactions: the American Red Cross experience (2004-2006) [J].
Eder, Anne F. ;
Kennedy, Jean M. ;
Dy, Beth A. ;
Notari, Edward P. ;
Weiss, John W. ;
Fang, Chyang T. ;
Wagner, Stephen ;
Dodd, Roger Y. ;
Benjamin, Richard J. .
TRANSFUSION, 2007, 47 (07) :1134-1142
[9]   Loss of red cell mass in a plasmapheresis machine: Effect of rinsing the disposable tubing with normal saline and reinfusion [J].
Fischer, Thorsten ;
Surikova, Irina ;
Heesen, Ewa ;
Wilms, Galina ;
Laitinen, Teija ;
Taborski, Uwe .
TRANSFUSION AND APHERESIS SCIENCE, 2013, 49 (01) :80-83
[10]   Plateletpheresis-associated lymphopenia in frequent platelet donors [J].
Gansner, John M. ;
Rahmani, Mahboubeh ;
Jonsson, A. Helena ;
Fortin, Brooke M. ;
Brimah, Idayat ;
Ellis, Martha ;
Smeland-Wagman, Robin ;
Li, Zhihan J. ;
Schenkel, Jason M. ;
Brenner, Michael B. ;
Yefidoff-Freedman, Revital ;
Sloan, Steven R. ;
Berliner, Nancy ;
Issa, Nicolas C. ;
Baden, Lindsey R. ;
Longo, Dan L. ;
Wesemann, Duane R. ;
Neuberg, Donna ;
Rao, Deepak A. ;
Kaufman, Richard M. .
BLOOD, 2019, 133 (06) :605-614