The effect of sampling window size on topographical maps of foveal cone density

被引:0
|
作者
Warr, Emma [1 ]
Grieshop, Jenna [1 ,2 ,3 ]
Cooper, Robert F. [1 ,2 ,3 ]
Carroll, Joseph [1 ,2 ,3 ,4 ]
机构
[1] Med Coll Wisconsin, Dept Ophthalmol & Visual Sci, Milwaukee, WI 53226 USA
[2] Marquette Univ, Joint Dept Biomed Engn, Milwaukee, WI 53233 USA
[3] Med Coll Wisconsin, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
来源
FRONTIERS IN OPHTHALMOLOGY | 2024年 / 4卷
关键词
fovea; cone density; cone spacing; adaptive optics; retina; PHOTORECEPTOR PACKING DENSITY; VARIABILITY; ROD; ECCENTRICITY; FIXATION; METRICS; IMAGES;
D O I
10.3389/fopht.2024.1348950
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To characterize the effect of sampling window size on maps of foveal cone density derived from adaptive optics scanning light ophthalmoscope (AOSLO) images of the cone mosaic. Methods: Forty-four AOSLO-derived montages of the foveal cone mosaic (300 x 300 mu m) were used for this study (from 44 individuals with normal vision). Cone photoreceptor coordinates were semi-automatically identified by one experienced grader. From these coordinates, cone density matrices across each foveal montage were derived using 10 different sampling window sizes containing 5, 10, 15, 20, 40, 60, 80, 100, 150, or 200 cones. For all 440 density matrices, we extracted the location and value of peak cone density (PCD), the cone density centroid (CDC) location, and cone density at the CDC. Results: Across all window sizes, PCD values were larger than those extracted at the CDC location, though the difference between these density values decreased as the sampling window size increased (p<0.0001). Overall, both PCD (r=-0.8099, p=0.0045) and density at the CDC (r=-0.7596, p=0.0108) decreased with increasing sampling window size. This reduction was more pronounced for PCD, with a 27.8% lower PCD value on average when using the 200-cone versus the 5-cone window (compared to only a 3.5% reduction for density at the CDC between these same window sizes). While the PCD and CDC locations did not occur at the same location within a given montage, there was no significant relationship between this PCD-CDC offset and sampling window size (p=0.8919). The CDC location was less variable across sampling windows, with an average per-participant 95% confidence ellipse area across the 10 window sizes of 47.56<mu>m(2) (compared to 844.10 mu m(2) for the PCD location, p<0.0001). Conclusion: CDC metrics appear more stable across varying sampling window sizes than PCD metrics. Understanding how density values change according to the method used to sample the cone mosaic may facilitate comparing cone density data across different studies.
引用
收藏
页数:11
相关论文
共 27 条
  • [21] Effect of voxel size on accuracy of cone beam computed tomographye-aided assessment of periodontal furcation involvement
    Kamburoglu, Kivanc
    Eres, Gulden
    Akgun, Ceren
    Yeta, Elif Naz
    Gulen, Orhan
    Karacaoglu, Fatma
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (05): : 644 - 650
  • [22] Quantifying the effect of sampling plot size on the estimation of structural indicators in old-growth forest stands
    Lombardi, F.
    Marchetti, M.
    Corona, P.
    Merlini, P.
    Chirici, G.
    Tognetti, R.
    Burrascano, S.
    Alivernini, A.
    Puletti, N.
    FOREST ECOLOGY AND MANAGEMENT, 2015, 346 : 89 - 97
  • [23] Exploring the Effect of Sampling Density on Spatial Prediction with Spatial Interpolation of Multiple Soil Nutrients at a Regional Scale
    Dash, Prava Kiran
    Miller, Bradley A.
    Panigrahi, Niranjan
    Mishra, Antaryami
    LAND, 2024, 13 (10)
  • [24] Detecting spatial structures in throughfall data: The effect of extent, sample size, sampling design, and variogram estimation method
    Voss, Sebastian
    Zimmermann, Beate
    Zimmermann, Alexander
    JOURNAL OF HYDROLOGY, 2016, 540 : 527 - 537
  • [25] The effect of sampling frequency and spatial and temporal variation in the density of fecal indicator bacteria on the assessment of coastal bathing water quality
    Jozic, Slaven
    Cenov, Arijana
    Glad, Marin
    Peros-Pucar, Danijela
    Kuric, Katarina
    Puljak, Tatjana
    Ordulj, Marin
    Tomas, Ana Vrdoljak
    Baumgartner, Nikolina
    Ivankovic, Damir
    Solic, Mladen
    Grilec, Dolores
    Lusic, Darija Vukic
    WATER RESEARCH, 2024, 264
  • [26] Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling
    Tward, Daniel J.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2009, 36 (08) : 3830 - 3843
  • [27] Accuracy of detecting vertical root fractures in non-root filled teeth using cone beam computed tomography: effect of voxel size and fracture width
    Guo, X. L.
    Li, G.
    Zheng, J. Q.
    Ma, R. H.
    Liu, F. C.
    Yuan, F. S.
    Lyu, P. J.
    Guo, Y. J.
    Yin, S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (06) : 887 - 898