The effect of sampling window size on topographical maps of foveal cone density

被引:0
|
作者
Warr, Emma [1 ]
Grieshop, Jenna [1 ,2 ,3 ]
Cooper, Robert F. [1 ,2 ,3 ]
Carroll, Joseph [1 ,2 ,3 ,4 ]
机构
[1] Med Coll Wisconsin, Dept Ophthalmol & Visual Sci, Milwaukee, WI 53226 USA
[2] Marquette Univ, Joint Dept Biomed Engn, Milwaukee, WI 53233 USA
[3] Med Coll Wisconsin, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
来源
FRONTIERS IN OPHTHALMOLOGY | 2024年 / 4卷
关键词
fovea; cone density; cone spacing; adaptive optics; retina; PHOTORECEPTOR PACKING DENSITY; VARIABILITY; ROD; ECCENTRICITY; FIXATION; METRICS; IMAGES;
D O I
10.3389/fopht.2024.1348950
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To characterize the effect of sampling window size on maps of foveal cone density derived from adaptive optics scanning light ophthalmoscope (AOSLO) images of the cone mosaic. Methods: Forty-four AOSLO-derived montages of the foveal cone mosaic (300 x 300 mu m) were used for this study (from 44 individuals with normal vision). Cone photoreceptor coordinates were semi-automatically identified by one experienced grader. From these coordinates, cone density matrices across each foveal montage were derived using 10 different sampling window sizes containing 5, 10, 15, 20, 40, 60, 80, 100, 150, or 200 cones. For all 440 density matrices, we extracted the location and value of peak cone density (PCD), the cone density centroid (CDC) location, and cone density at the CDC. Results: Across all window sizes, PCD values were larger than those extracted at the CDC location, though the difference between these density values decreased as the sampling window size increased (p<0.0001). Overall, both PCD (r=-0.8099, p=0.0045) and density at the CDC (r=-0.7596, p=0.0108) decreased with increasing sampling window size. This reduction was more pronounced for PCD, with a 27.8% lower PCD value on average when using the 200-cone versus the 5-cone window (compared to only a 3.5% reduction for density at the CDC between these same window sizes). While the PCD and CDC locations did not occur at the same location within a given montage, there was no significant relationship between this PCD-CDC offset and sampling window size (p=0.8919). The CDC location was less variable across sampling windows, with an average per-participant 95% confidence ellipse area across the 10 window sizes of 47.56<mu>m(2) (compared to 844.10 mu m(2) for the PCD location, p<0.0001). Conclusion: CDC metrics appear more stable across varying sampling window sizes than PCD metrics. Understanding how density values change according to the method used to sample the cone mosaic may facilitate comparing cone density data across different studies.
引用
收藏
页数:11
相关论文
共 27 条
  • [11] The Henle Fiber Layer in Albinism: Comparison to Normal and Relationship to Outer Nuclear Layer Thickness and Foveal Cone Density
    Lee, Daniel J.
    Woertz, Erica N.
    Visotcky, Alexis
    Wilk, Melissa A.
    Heitkotter, Heather
    Linderman, Rachel E.
    Tarima, Sergey
    Summers, C. Gail
    Brooks, Brian P.
    Brilliant, Murray H.
    Antony, Bhavna J.
    Lujan, Brandon J.
    Carroll, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (13) : 5336 - 5348
  • [12] EFFECTS OF SIZE AND SAMPLING GRID ON THE QUALITY OF APPARENT SOIL ELECTRICAL CONDUCTIVITY MAPS
    Oldoni, Henrique
    Costa, Bruno R. S.
    Rocha Junior, Romero C.
    Rabe, Ladislau M.
    Bassoi, Luis H.
    ENGENHARIA AGRICOLA, 2019, 39 : 1 - 12
  • [13] Intraobserver Repeatability and Interobserver Reproducibility of Foveal Cone Density Measurements in CNGA3- and CNGB3-Associated Achromatopsia
    Georgiou, Michalis
    Litts, Katie M.
    Singh, Navjit
    Kane, Thomas
    Patterson, Emily J.
    Hirji, Nashila
    Kalitzeos, Angelos
    Dubra, Alfredo
    Michaelides, Michel
    Carroll, Joseph
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (07): : 1 - 10
  • [14] Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT
    Maret, D.
    Telmon, N.
    Peters, O. A.
    Lepage, B.
    Treil, J.
    Inglese, J. M.
    Peyre, A.
    Kahn, J. L.
    Sixou, M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (08) : 649 - 655
  • [15] Standardization of mineral density maps of physiologic and pathologic biominerals in humans using cone-beam CT and micro-CT scanners
    Srirangapatanam, Sudarshan
    Kang, Misun
    Ellenikiotis, Yianni
    Jheon, Andrew
    Kapila, Sunil
    Swana, Hubert S.
    Stoller, Marshall L.
    Seo, Youngho
    Ho, Sunita P.
    DENTAL MATERIALS, 2022, 38 (06) : 989 - 1003
  • [16] Effect of Sampling Size on the Determination of Accurate Pesticide Residue Levels in Japanese Agricultural Commodities
    Fujita, Masahiro
    Yajima, Tomonari
    Iijima, Kazuaki
    Sato, Kiyoshi
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (18) : 4457 - 4464
  • [17] Effect of Voxel Size on Detection of External Root Resorption Defects Using Cone Beam Computed Tomography
    Nikneshan, Sima
    Valizadeh, Solmaz
    Javanmard, Anahita
    Alibakhshi, Leila
    IRANIAN JOURNAL OF RADIOLOGY, 2016, 13 (03)
  • [18] Characterization of the density and body size of a Gammarus pulex (Crustacea: Amphipoda) population in subsurface sediments reflects the sampling technique used
    Stubbington, Rachel
    Hogan, John-Paul
    Wood, Paul J.
    HYDROBIOLOGIA, 2017, 788 (01) : 293 - 303
  • [19] The effect of fixation on the size, shape and summed optical density of endometrial cancer nuclei
    Geisler, JP
    Geisler, HE
    Wiemann, MC
    Zhou, Z
    Miller, GA
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 1998, 19 (03) : 239 - 241
  • [20] Blue Cone Monochromatism with Foveal Hypoplasia Caused by the Concomitant Effect of Variants in OPN1LW/OPN1MW and GPR143 Genes
    Iarossi, Giancarlo
    Coppe, Andrea Maria
    Passarelli, Chiara
    Maltese, Paolo Enrico
    Sinibaldi, Lorenzo
    Cappelli, Alessandro
    Cetola, Sarah
    Novelli, Antonio
    Buzzonetti, Luca
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (16)