Association between the Mean Platelet Volume and Prosthesis-patient Mismatch after Transcatheter Aortic Valve Replacement

被引:0
作者
Morita, Yuichi [1 ]
Ikenaga, Hiroki [1 ]
Takeda, Atsushi [2 ]
Nakano, Takayuki [1 ]
Higashihara, Tasuku [1 ]
Watanabe, Noriaki [1 ]
Sada, Yoshiharu [1 ]
Utsunomiya, Hiroto [1 ]
Takahashi, Shinya [3 ]
Fukuda, Yukihiro [4 ]
Nakano, Yukiko [1 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Cardiovasc Med, Hiroshima, Japan
[2] Hiroshima City Hiroshima Citizens Hosp, Dept Cardiovasc Med, Hiroshima, Japan
[3] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Cardiovasc Surg, Hiroshima, Japan
[4] Hiroshima Prefectural Hosp, Dept Cardiovasc Med, Hiroshima, Japan
关键词
aortic stenosis; transcatheter aortic valve replacement; mean platelet volume; prosthesis-patient mismatch; HIGH-RISK PATIENTS; CLINICAL IMPACT; EUROPEAN ASSOCIATION; ACTIVATION; OUTCOMES; PREDICTORS; IMPLANTATION; DEFINITIONS; STENOSIS; SURVIVAL;
D O I
10.2169/internalmedicine.4205-24
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective The mean platelet volume (MPV), a marker of platelet activity, is significantly higher in patients with aortic stenosis (AS) than in those without AS. The association between the platelet function and prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) remains unknown. Therefore, we investigated this association by measuring the MPV. Methods Of 237 patients who underwent TAVR, 148 with a median age of 84 years old were enrolled in this study. Blood tests and transthoracic echocardiography were performed at baseline and approximately six months after TAVR. PPM was defined as an aortic valve area index <= 0.85 cm(2) after TAVR. Variable changes from baseline to six-month follow-up were compared between patients with and without PPM. Results Forty-five patients (30%) developed PPM. The MPV was significantly higher in patients with PPM than in those without PPM. However, regarding the magnitude of change, the MPV was significantly less reduced in patients with PPM, and the percentage of patients with reduced MPV was lower in patients with PPM than in those without PPM. A logistic regression analysis revealed that a higher MPV and lack of MPV reduction at the six-month follow-up were independent predictors of PPM. Conclusion MPV values at the six-month follow-up were associated with PPM after TAVR in patients with AS. MPV values increase when PPM is present after TAVR and may be an indicator during the postoperative follow-up.
引用
收藏
页码:1171 / 1179
页数:9
相关论文
共 39 条
[1]  
Baumgartner H, 2017, J AM SOC ECHOCARDIOG, V30, P372, DOI [10.1016/j.echo.2017.02.009, 10.1093/ehjci/jew335]
[2]   Assessment of mean platelet volume in coronary artery disease - What does it mean? [J].
Boos, Christopher J. ;
Lip, Gregory Y. H. .
THROMBOSIS RESEARCH, 2007, 120 (01) :11-13
[3]   Standardized definitions of structural deterioration and valve failure in assessing long-termdurability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) endorsed by the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) [J].
Capodanno, Davide ;
Petronio, Anna S. ;
Prendergast, Bernard ;
Eltchaninoff, Helene ;
Vahanian, Alec ;
Modine, Thomas ;
Lancellotti, Patrizio ;
Sondergaard, Lars ;
Ludman, Peter F. ;
Tamburino, Corrado ;
Piazza, Nicolo ;
Hancock, Jane ;
Mehilli, Julinda ;
Byrne, Robert A. ;
Baumbach, Andreas ;
Kappetein, Arie Pieter ;
Windecker, Stephan ;
Bax, Jeroen ;
Haude, Michael .
EUROPEAN HEART JOURNAL, 2017, 38 (45) :3382-+
[4]   Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement [J].
Dayan, Victor ;
Vignolo, Gustavo ;
Soca, Gerardo ;
Paganini, Juan Jose ;
Brusich, Daniel ;
Pibarot, Philippe .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) :924-933
[5]  
Dimitrow Pawel Petkow, 2009, Atherosclerosis, V204, pe103, DOI 10.1016/j.atherosclerosis.2008.12.029
[6]   Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation [J].
Ewe, See Hooi ;
Muratori, Manuela ;
Delgado, Victoria ;
Pepi, Mauro ;
Tamborini, Gloria ;
Fusini, Laura ;
Klautz, Robert J. M. ;
Gripari, Paola ;
Bax, Jeroen J. ;
Fusari, Melissa ;
Schalij, Martin J. ;
Marsan, Nina Ajmone .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) :1910-1918
[7]   The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement [J].
Fallon, John M. ;
DeSimone, Joseph P. ;
Brennan, J. Matthew ;
O'Brien, Sean ;
Thibault, Dylan P. ;
DiScipio, Anthony W. ;
Pibarot, Philippe ;
Jacobs, Jeffrey P. ;
Malenka, David J. ;
Clarizia, Nadia A. ;
Ruel, Marc .
ANNALS OF THORACIC SURGERY, 2018, 106 (01) :14-23
[8]   3-Year Outcomes After Transcatheter or Surgical Aortic Valve Replacement in Low-Risk Patients With Aortic Stenosis [J].
Forrest, John K. ;
Deeb, G. Michael ;
Yakubov, Steven J. ;
Gada, Hemal ;
Mumtaz, Mubashir A. ;
Ramlawi, Basel ;
Bajwa, Tanvir ;
Teirstein, Paul S. ;
DeFrain, Michael ;
Muppala, Murali ;
Rutkin, Bruce J. ;
Chawla, Atul ;
Jenson, Bart ;
Chetcuti, Stanley J. ;
Stoler, Robert C. ;
Poulin, Marie-France ;
Khabbaz, Kamal ;
Levack, Melissa ;
Goel, Kashish ;
Tchetche, Didier ;
Lam, Ka Yan ;
Tonino, Pim A. L. ;
Ito, Saki ;
Oh, Jae K. ;
Huang, Jian ;
Popma, Jeffrey J. ;
Kleiman, Neal ;
Reardon, Michael J. ;
Low Risk Trial Investigators .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (17) :1663-1674
[9]   Hematologic and Clinical Parameters After Transcatheter Aortic Valve Implantation (TAVI) in Patients With Severe Aortic Stenosis [J].
Gul, Mehmet ;
Uyarel, Huseyin ;
Akgul, Ozgur ;
Uslu, Nevzat ;
Yildirim, Aydin ;
Eksik, Abdurrahman ;
Aksu, Hale Unal ;
Ozal, Ender ;
Pusuroglu, Hamdi ;
Erol, Mustafa Kemal ;
Bakir, Ihsan .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2014, 20 (03) :304-310
[10]   Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement A meta-analysis [J].
He, Shixin ;
Fang, Zhenfei .
MEDICINE, 2020, 99 (24) :E20717