Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

被引:1
作者
Quintard, Bradyn [1 ]
Yang, Xi [2 ]
Wang, Liguo [3 ]
机构
[1] Dartmouth Coll, Dept Phys & Astron, Hanover, NH 03755 USA
[2] Brookhaven Natl Lab, Natl Synchrotron Light Source 2, Upton, NY 11973 USA
[3] Brookhaven Natl Lab, Lab Biomol Struct, Upton, NY 11973 USA
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 02期
关键词
Monte Carlo simulation; MeV-STEM; Beer Lambert law; electron-specimen interaction; nanometer resolution; thick biological samples; ULTRASTRUCTURE; TOMOGRAPHY; MICROSCOPY;
D O I
10.3390/app15020565
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 mu m in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron-sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer-Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 mu m at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 mu m at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.
引用
收藏
页数:13
相关论文
共 49 条
[31]   Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM [J].
Yang, Xi ;
Wang, Liguo ;
Smaluk, Victor ;
Shaftan, Timur .
NANOMATERIALS, 2024, 14 (09)
[32]   Monte Carlo modeling of low-energy electron-induced secondary electron emission yields in micro-architected boron nitride surfaces [J].
Chang, Hsing-Yin ;
Alvarado, Andrew ;
Weber, Trey ;
Marian, Jaime .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 454 :14-22
[33]   A Monte-Carlo simulation of the equilibrium beam polarization in ultra-high energy electron (positron) storage rings [J].
Duan, Zhe ;
Bai, Mei ;
Barber, Desmond P. ;
Qin, Qing .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 793 :81-91
[34]   Monte Carlo assessment of soil moisture effect on high-energy thermal neutron capture gamma-ray by 14N [J].
Pazirandeh, A ;
Azizi, M ;
Masoudi, SF .
APPLIED RADIATION AND ISOTOPES, 2006, 64 (01) :1-6
[35]   Overcoming implementation barriers to renewable energy in developing nations: A case study of Iran using MCDM techniques and monte carlo simulation [J].
Soltani, Amir ;
Imani, Mohammad Amin .
RESULTS IN ENGINEERING, 2024, 24
[36]   Experimental Study and Monte-Carlo Simulation of Exchange Bias Effect in Co-CoO Composite Powder Fabricated by High-Energy Ball Milling [J].
Ky, V. H. ;
Hieu, N. T. ;
Tung, D. K. ;
Phong, L. T. H. ;
Manh, D. H. ;
Kunca, B. ;
Marcin, J. ;
Skorvanek, I. .
JOURNAL OF ELECTRONIC MATERIALS, 2019, 48 (12) :7952-7959
[37]   Experimental Study and Monte-Carlo Simulation of Exchange Bias Effect in Co-CoO Composite Powder Fabricated by High-Energy Ball Milling [J].
V. H. Ky ;
N. T. Hieu ;
D. K. Tung ;
L. T. H. Phong ;
D. H. Manh ;
B. Kunca ;
J. Marcin ;
I. Skorvanek .
Journal of Electronic Materials, 2019, 48 :7952-7959
[38]   Monte Carlo simulation of a new proton therapy technique using bio-nanoparticles and high energy proton beams [J].
Ouar, M. ;
Dib, A. S. Amine ;
Belkaid, M. N. ;
Belbachir, A. H. ;
Ouar, Mohammed .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (03) :615-619
[39]   A Monte Carlo simulation surveying direct DNA damage using different biologically relevant electron energy, absorbed dose, electron tracking and base pair cutoff [J].
Ahmed, Mariam M. ;
Ali, M. ;
Moustafa, Mona ;
Khalil, Magdy M. .
RADIATION PHYSICS AND CHEMISTRY, 2025, 236
[40]   Monte Carlo calculations of low-energy electron dose-point-kernels in water using different stopping power approximations [J].
Bousis, Christos ;
Emfietzoglou, Dimitris ;
Hadjidoukas, Panagiotis ;
Nikjoo, Hooshang ;
Pathak, Anand .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (14) :1650-1654