Hybrid iterative reconstruction in ultra-low-dose CT for accurate pulmonary nodule assessment: A Phantom study

被引:0
作者
Chen, Li-Guo [1 ]
Kao, Hung-Wen [1 ,2 ]
Wu, Ping-An [1 ]
Sheu, Ming-Huei [1 ]
Tu, Hsing-Yang [1 ]
Huang, Li-Chuan [1 ,3 ]
机构
[1] Hualien Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Med Imaging, Hualien, Taiwan
[2] Tzu Chi Univ, Sch Med, Dept Radiol, Hualien, Taiwan
[3] Tzu Chi Univ, Dept Med Imaging & Radiol Sci, Hualien, Taiwan
关键词
hybrid iterative reconstruction; iDose(4) algorithm; noise reduction; Phantom study; pulmonary nodules; solid nodule detection; FILTERED BACK-PROJECTION; PART-SOLID NODULES; LUNG-CANCER; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RADIATION-EXPOSURE; BASE-LINE; CHEST; SETTINGS; OPTIMIZATION;
D O I
10.1097/MD.0000000000041612
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated hybrid iterative reconstruction in ultra-low-dose computed tomography (ULDCT) for solid pulmonary nodule detection. A 256-slice CT machine operating at 120 kVp imaged a chest phantom with 5 mm nodules. The imaging process involved adjusting low-dose computed tomography (LDCT) settings and conducting 3 ULDCT scans (A-C) with varied minimum and maximum mA settings (10/40 mA). Images were processed using iDose4 iterative reconstruction at levels 5 to 7. Measurements were taken for noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), noise power spectrum (NPS), and detectability index (D') to assess image quality, noise texture, and detectability. Analysis of variance (ANOVA) was used to compare the protocols. Noise levels varied significantly across iDose4 iterative reconstruction levels, with the highest noise at 178 HU in iDose4 L5 (protocol C) and the lowest at 54.85 HU in level 7 (protocol A). ULDCT scans showed noise increases of 38.5%, 104.2%, and 118.7% for protocols A, B, and C, respectively, compared to LDCT. Protocol A (iDose4 level 7) significantly improved SNR and CNR (P < .001). The mean volume CT dose index was 2.4 mGy for LDCT and 2.0 mGy, 1.2 mGy, and 0.7 mGy for ULDCT protocols A, B, and C, respectively. Increasing iDose4 levels reduced noise magnitude in the NPS and improved the D'. ULDCT with iDose4 level 7 provides diagnostically acceptable image quality for solid pulmonary nodule assessment at significantly reduced radiation doses. This approach, supported by advanced metrics like NPS and D', demonstrates a potential pathway for safer, effective lung cancer screening in high-risk populations. Further clinical studies are needed to validate these findings in diverse patient populations.
引用
收藏
页数:7
相关论文
共 42 条
[1]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]   Performance of ultralow-dose CT with iterative reconstruction in lung cancer screening: limiting radiation exposure to the equivalent of conventional chest X-ray imaging [J].
Adrian, Huber ;
Julia, Landau ;
Ebner, Lukas ;
Yanik, Butikofer ;
Lars, Leidolt ;
Barbara, Brela ;
Michelle, May ;
Johannes, Heverhagen ;
Andreas, Christe .
EUROPEAN RADIOLOGY, 2016, 26 (10) :3643-3652
[3]   Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast [J].
Albrecht, Moritz H. ;
Scholtz, Jan-Erik ;
Huesers, Kristina ;
Beeres, Martin ;
Bucher, Andreas M. ;
Kaup, Moritz ;
Martin, Simon S. ;
Fischer, Sebastian ;
Bodelle, Boris ;
Bauer, Ralf W. ;
Lehnert, Thomas ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN RADIOLOGY, 2016, 26 (06) :1863-1870
[4]  
[Anonymous], 2006, Health risks from exposure to low levels of ionizing radiation: BEIR VII Phase 2
[5]   Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography [J].
Apfaltrer, Paul ;
Sudarski, Sonja ;
Schneider, David ;
Nance, John W., Jr. ;
Haubenreisser, Holger ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :322-328
[6]   Using "iDose4" iterative reconstruction algorithm in adults' chest-abdomen-pelvis CT examinations: effect on image quality in relation to patient radiation exposure [J].
Arapakis, I. ;
Efstathopoulos, E. ;
Tsitsia, V. ;
Kordolaimi, S. ;
Economopoulos, N. ;
Argentos, S. ;
Ploussi, A. ;
Alexopoulou, E. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1036)
[7]   A comprehensive assessment of physical image quality of five different scanners for head CT imaging as clinically used at a single hospital centre-A phantom study [J].
Barca, Patrizio ;
Paolicchi, Fabio ;
Aringhieri, Giacomo ;
Palmas, Federica ;
Marfisi, Daniela ;
Fantacci, Maria Evelina ;
Caramella, Davide ;
Giannelli, Marco .
PLOS ONE, 2021, 16 (01)
[8]  
Bongartz G., 2004, European guidelines for multislice computed tomography
[9]   Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[10]   CT Scans and Cancer Risks: A Systematic Review and Dose-response Meta-analysis [J].
Cao, Chun-Feng ;
Ma, Kun-Long ;
Shan, Hua ;
Liu, Tang-Fen ;
Zhao, Si-Qiao ;
Wan, Yi ;
Jun-Zhang, Hai-Qiang ;
Wang, Hai-Qiang .
BMC CANCER, 2022, 22 (01)