Echocardiography - a non-invasive alternative for assessing cardiac morphology and function in Atlantic salmon (Salmo salar L.)

被引:1
作者
Becker, Victoria [1 ,2 ,3 ]
Kavaliauskiene, Simona [1 ,2 ,3 ]
Sandblom, Erik [4 ]
Zena, Lucas A. [4 ,5 ]
Grans, Albin [5 ]
Louch, William E. [1 ,2 ,3 ]
Sjaastad, Ivar [1 ,2 ,3 ]
Johansen, Ida B. [6 ]
Frisk, Michael [1 ,2 ,3 ]
机构
[1] Univ Oslo, Inst Expt Med Res, Oslo, Norway
[2] Oslo Univ Hosp Ulleval, Oslo, Norway
[3] Univ Oslo, KG Jebsen Ctr Cardiac Res, Oslo, Norway
[4] Univ Gothenburg, Dept Biol & Environm Sci, Gothenburg, Sweden
[5] Swedish Univ Agr Sci, Dept Appl Anim Sci & Welf, Gothenburg, Sweden
[6] Norwegian Univ Life Sci, Fac Vet Med, Dept Preclin Sci & Pathol, As, Norway
关键词
Ultrasound; Repeatability; Reproducibility; Reliability; Heart physiology; DOPPLER-ECHOCARDIOGRAPHY; VELOCITY-MEASUREMENTS; MEASUREMENT ERRORS; HEART VENTRICLE; RAINBOW-TROUT; CATECHOLAMINES; TEMPERATURE; DISEASE;
D O I
10.1016/j.aquaculture.2024.741223
中图分类号
S9 [水产、渔业];
学科分类号
0908 ;
摘要
Cardiac-related mortality is increasing in farmed salmon. Non-invasive tools for examining and screening for cardiac morphology and function are limited, and most common methodologies are lethal, time-consuming, and immobile. Echocardiography has previously been tested as a non-invasive, quick, and portable alternative, though its implementation is minimal. Improvements in echocardiographic techniques during the last decade have enabled more refined assessments of structure and function and hold potential for use in fish farms. Utilising a compact, transportable ultrasound system, we examined the applicability of echocardiography in Atlantic salmon (Salmo salar L.). Several protocols and projections were tested, and intra- and inter-variation for both operators (image acquisition) and observers (image analysis) were assessed. In addition, the accuracy of cardiac structure/function measurements was compared with standard methods. In general, high accuracy and reproducibility of cardiac dimensions and functional parameters were found within the same and between different observers analysing the same dataset (intra- and inter-observer). Measurements between recordings of the same operator (intra-operator) and between different operators (inter-operator) were less accurate and repeatable but comparable to observations in previous human and mammalian studies. Cardiac output was slightly higher when measured with echocardiography compared to transit time flow probe. Yet, a strong correlation exists between the two methods. Furthermore, morphology measured in excised hearts ex vivo was comparable to echocardiography measurements and strongly correlated. Thus, ultrasound presents a highly feasible, non-invasive, and swift alternative to current methods for detailed cardiac assessment of salmon hearts.
引用
收藏
页数:10
相关论文
共 53 条
  • [1] Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables
    Bartlett, J. W.
    Frost, C.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) : 466 - 475
  • [2] Echocardiographic assessment of left ventricular size and systolic function in Warmblood horses using linear measurements, area-based indices, and volume estimates: A retrospective database analysis
    Berthoud, Djamila
    Schwarzwald, Colin C.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (01) : 504 - 520
  • [3] Statistics notes: Measurement error proportional to the mean .23.
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 313 (7049) : 106 - 106
  • [4] Form and function of the bulbus arteriosus in yellowfin tuna (Thunnus albacares):: dynamic properties
    Braun, MH
    Brill, RW
    Gosline, JM
    Jones, DR
    [J]. JOURNAL OF EXPERIMENTAL BIOLOGY, 2003, 206 (19) : 3327 - 3335
  • [5] Prevalence and severity of cardiac abnormalities and arteriosclerosis in farmed rainbow trout (Oncorhynchus mykiss)
    Brijs, J.
    Hjelmstedt, P.
    Berg, C.
    Johansen, I. B.
    Sundh, H.
    Roques, J. A. C.
    Ekstrom, A.
    Sandblom, E.
    Sundell, K.
    Olsson, C.
    Axelsson, M.
    Grans, A.
    [J]. AQUACULTURE, 2020, 526
  • [6] A Practical Guide to Assess the Reproducibility of Echocardiographic Measurements
    Bunting, Karina V.
    Steeds, Richard P.
    Slater, Karin
    Rogers, Jennifer K.
    Gkoutos, Georgios V.
    Kotecha, Dipak
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (12) : 1505 - 1515
  • [7] Using maximum heart rate as a rapid screening tool to determine optimum temperature for aerobic scope in Pacific salmon Oncorhynchus spp.
    Casselman, M. T.
    Anttila, K.
    Farrell, A. P.
    [J]. JOURNAL OF FISH BIOLOGY, 2012, 80 (02) : 358 - 377
  • [8] Cardiac hemodynamics of the rainbow trout (Oncorhynchus mykiss) using simultaneous Doppler echocardiography and electrocardiography
    Cotter, Paul A.
    Han, Adrienne J.
    Everson, James J.
    Rodnick, Kenneth J.
    [J]. JOURNAL OF EXPERIMENTAL ZOOLOGY PART A-ECOLOGICAL AND INTEGRATIVE PHYSIOLOGY, 2008, 309A (05) : 243 - 254
  • [9] Coucelo J, 2000, J EXP ZOOL, V286, P585, DOI 10.1002/(SICI)1097-010X(20000501)286:6<585::AID-JEZ5>3.0.CO
  • [10] 2-Z