A novel ratiometric electrochemical aptasensor based on graphene quantum dots/Cu-MOF nanocomposite for the on-site determination of Staphylococcus aureus

被引:2
|
作者
Lin, Xiaofeng [1 ]
Liu, Chenghao [1 ]
Lei, Qiaowen [1 ]
Nan, Xinru [1 ]
Zhu, Yunxiao [1 ]
Liao, Jing [1 ]
Du, Zhizhi [1 ]
Ye, Chenyi [1 ]
Xiong, Yixian [1 ]
Yang, Min [1 ]
Fang, Xiaojun [1 ]
Luo, Yan [1 ,2 ]
Huang, Qitong [1 ]
机构
[1] Gannan Med Univ, Sch Med & Informat Engn,Minist Educ,Key Lab Biomed, Sci Res Ctr,Jiangxi Prov Key Lab Tissue Engn, Sch Pharm,Key Lab Prevent & Treatment Cardiovasc &, Ganzhou 341000, Peoples R China
[2] Univ Kansas, Sch Pharm, Dept Pharmacol & Toxicol, Lawrence, KS 66045 USA
关键词
Graphene quantum dots; Cu-MOF; Staphylococcus aureus; Ratiometric electrochemical aptasensor;
D O I
10.1016/j.jhazmat.2024.136845
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The sensitive detection of Staphylococcus aureus (S. aureus) holds great practical importance for ensuring public health and food safety. In this study, a sensitivity and stability ratiometric electrochemical aptasensor using graphene quantum dots/[Cu2.5 (benzotriazole-5-COO)1.5 (benzotriazole-5-COOH)0.5 (mu-Cl)0.5 (mu 3-OH)-(H2O)]& sdot; 3 H2O nanocomposite (GQDs/Cu-MOF) was constructed for S. aureus detection. The GQDs enhanced the sensitivity of the electrochemical aptasensor due to their excellent conductivity and provided stability through their abundant carboxyl groups. The Cu-MOF, possessing electrical activity, not only enhanced the performance of the electrochemical aptasensor but also served as a signal label. The single-stranded DNA1 (S1) was immobilized on the surface of a GQDs/Cu-MOF/screen-printed carbon electrode (S1/GQDs/Cu-MOF/SPCE) as the sensing interface. Subsequently, the S1/GQDs/Cu-MOF/SPCE was hybridized with the probe DNA-ferrocene (S2-Fc), resulting in the generation of electrochemical signals from Cu-MOF ( I Cu-MOF ) and S2-ferrocene ( I S2-FC ) within the system. However, the electron transfer performance of DNA at the sensing interface was compromised, leading to a reduction in the I Cu-MOF . When S. aureus was present in the system, S2-Fc reacted with it and detached from the sensing surface, resulting in a gradual decrease in I S2-FC and an increase in I Cu-MOF . Then a ratiometric electro- chemical aptasensor was established for S. aureus detection with remarkable sensitivity (0.97 CFU center dot mL-1), excellent stability, and a broad linear range. Furthermore, the aptasensor was successfully applied to detect S. aureus in tap water, milk, Lonicera japonica, urine, and Zhangjiang River. Additionally, this aptasensor design can be adapted for the detection of other foodborne pathogens, which indicates that the design scheme of the aptasensor has good universality.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A novel ratiometric electrochemical aptasensor based on graphene quantum dots/Cu-MOF nanocomposite for the on-site determination of Staphylococcus aureus
    Lin, Xiaofeng
    Liu, Chenghao
    Lei, Qiaowen
    Nan, Xinru
    Zhu, Yunxiao
    Liao, Jing
    Du, Zhizhi
    Ye, Chenyi
    Xiong, Yixian
    Yang, Min
    Fang, Xiaojun
    Luo, Yan
    Huang, Qitong
    Journal of Hazardous Materials,
  • [2] A ratiometric electrochemical aptasensor for Ochratoxin A detection based on electroactive Cu-MOF and DNA conjugates resembling the structure of Bidens pilosa
    He, Donghao
    Dong, Na
    Li, Yuye
    Liu, Dong
    You, Tianyan
    ANALYTICA CHIMICA ACTA, 2025, 1342
  • [3] Construction of MOF@COF composite-based electrochemical aptasensor for detection of Staphylococcus aureus
    Meng, Yubo
    Ma, Zongzheng
    Huang, Yuchun
    Song, Yingpan
    ANALYTICAL SCIENCES, 2023, 39 (06) : 901 - 909
  • [4] Construction of MOF@COF composite-based electrochemical aptasensor for detection of Staphylococcus aureus
    Yubo Meng
    Zongzheng Ma
    Yuchun Huang
    Yingpan Song
    Analytical Sciences, 2023, 39 : 901 - 909
  • [5] Ratiometric electrochemical detection of alkaline phosphatase based on SWCNTs/Cu-MOF modified graphite paper electrodes
    Dong, Hui
    Zheng, Linlin
    Wang, Tao
    Li, Xinyue
    Liu, Ruiyu
    Liu, Zi
    Lv, Xuechuan
    Gao, Xiaohan
    Xu, Maotian
    Zhou, Yanli
    MICROCHEMICAL JOURNAL, 2024, 207
  • [6] Novel electrochemical sensor based on graphene quantum dots/riboflavin nanocomposite for the detection of persulfate
    Roushani, Mahmoud
    Abdi, Zeinab
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 201 : 503 - 510
  • [7] An electrochemical aptasensor for detection of prostate-specific antigen using reduced graphene gold nanocomposite and Cu/carbon quantum dots
    Mehdipour, Golnaz
    Shayeh, Javad Shabani
    Omidi, Meysam
    Madadi, Mehrab Pour
    Yazdian, Fatemeh
    Tayebi, Lobat
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2022, 69 (05) : 2102 - 2111
  • [8] A novel "off-on" ratiometric fluorescent aptasensor for adenosine detection based on FRET between quantum dots and graphene oxide
    Li, Pu
    Luo, Chen
    Chen, Xiaoxiao
    Huang, Chaobiao
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 305
  • [9] Electrocatalysis of Cu-MOF/Graphene Composite and its Sensing Application for Electrochemical Simultaneous Determination of Dopamine and Paracetamol
    Ma, Baolong
    Guo, Hao
    Wang, Mingyue
    Li, Li
    Jia, Xueyan
    Chen, Huiqin
    Xue, Rui
    Yang, Wu
    ELECTROANALYSIS, 2019, 31 (06) : 1002 - 1008
  • [10] Graphene Quantum Dots as Probes in Electrochemical Immunoassay for Rapid and Sensitive Detection of Staphylococcus aureus
    Sirdeshmukh, Vedashree V.
    Apte, Harshika R.
    Kale, Anup A.
    2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 95 - 95