摘要
BackgroundRespiratory motion during radiotherapy (RT) may reduce the therapeutic effect and increase the dose received by organs at risk. This can be addressed by real-time tracking, where respiration motion prediction is currently required to compensate for system latency in RT systems. Notably, for the prediction of future images in image-guided adaptive RT systems, the use of deep learning has been considered.PurposeThis study proposed a modified generative adversarial network (GAN) for predicting cine-MR images in real time.MethodsSagittal cine magnetic resonance (cine-MR) images of 15 patients with liver cancer who received RT were collected. The image series length of each patient was 300, and each series was divided into training, validation, and test sets. The datasets were further divided using a sliding window size of 10 and a stride of 1. A pix2pix GAN with the generator replaced by convolutional long short-term memory (ConvLSTM) was proposed herein. A five-frame cine-MR image series was inputted into the network, which predicted the next five frames. The proposed network was compared with three advanced networks: ConvLSTM, Eidetic 3D LSTM (E3D-LSTM), and SwinLSTM. Personalized models were trained for each patient. The peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), visual information fidelity (VIF), Pearson correlation coefficient (Pearson corr), and respiratory motion accuracy of the predicted images were used to evaluate the methods.ResultsThe proposed network demonstrated optimal performance in the four networks across various indicators. The proposed method provided better SSIM values than ConvLSTM at time steps 1, 2, 3, and 4, and outperformed E3DLSTM at all time steps. In terms of the VIF, the proposed method outperformed E3D-LSTM at all time steps and SwinLSTM at time steps 2, 3, 4, and 5. The proposed method was not significantly different from other methods in terms of Pearson correlation values except that it outperformed E3DLSTM at time step 1. In terms of the Pearson corr, the proposed method consistently achieves better values, especially in the high-frequency components. Low average landmark tracking errors were provided by the proposed method at time steps 4 and 5 (2.42 +/- 0.91 and 2.44 +/- 0.96 mm, respectively).ConclusionsThe GAN-ConvLSTM network can generate high-acutance real-time cine-MR images and predict respiratory motion with better accuracy.
引用
收藏
页码:3161 / 3172
页数:12
相关论文
共 38 条
[1]  
Arnold P., MEDIMAGE COMPUTCOMPU
[2]  
Azimi P, 2015, J SPINAL DISORD TECH, V28, pE161, DOI 10.1097/BSD.0000000000000200
[3]   Alignment of sparse freehand 3-D ultrasound with preoperative images of the liver using models of respiratory motion and deformation [J].
Blackall, JM ;
Penney, GP ;
King, AP ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (11) :1405-1416
[4]   MLC tracking for lung SABR is feasible, efficient and delivers high-precision target dose and lower normal tissue dose [J].
Booth, Jeremy ;
Caillet, Vincent ;
Briggs, Adam ;
Hardcastle, Nicholas ;
Angelis, Georgios ;
Jayamanne, Dasantha ;
Shepherd, Meegan ;
Podreka, Alexander ;
Szymura, Kathryn ;
Doan Trang Nguyen ;
Poulsen, Per ;
O'Brien, Ricky ;
Harris, Benjamin ;
Haddad, Carol ;
Eade, Thomas ;
Keall, Paul .
RADIOTHERAPY AND ONCOLOGY, 2021, 155 :131-137
[5]   Feasibility Study of Convolutional Long Short-Term Memory Network for Pulmonary Movement Prediction in CT Images [J].
Ghasemi Z. ;
Miandoab P.S. .
Journal of Biomedical Physics and Engineering, 2024, 14 (01) :55-66
[6]   Technical note: MLC racking performance on the Elekta unity MRI-linac [J].
Glitzner, M. ;
Woodhead, P. L. ;
Borman, P. T. S. ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15)
[7]   A comparison of neural network approaches for on-line prediction in IGRT [J].
Goodband, J. H. ;
Haas, O. C. L. ;
Mills, J. A. .
MEDICAL PHYSICS, 2008, 35 (03) :1113-1122
[8]   Hybrid Kalman Filters for Very Short-Term Load Forecasting and Prediction Interval Estimation [J].
Guan, Che ;
Luh, Peter B. ;
Michel, Laurent D. ;
Chi, Zhiyi .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) :3806-3817
[9]   Image-to-Image Translation with Conditional Adversarial Networks [J].
Isola, Phillip ;
Zhu, Jun-Yan ;
Zhou, Tinghui ;
Efros, Alexei A. .
30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, :5967-5976
[10]   AAPM Task Group 264: The safe clinical implementation of MLC tracking in radiotherapy [J].
Keall, Paul J. ;
Sawant, Amit ;
Berbeco, Ross, I ;
Booth, Jeremy T. ;
Cho, Byungchul ;
Cervino, Laura, I ;
Cirino, Eileen ;
Dieterich, Sonja ;
Fast, Martin F. ;
Greer, Peter B. ;
Af Rosenschold, Per Munck ;
Parikh, Parag J. ;
Poulsen, Per Rugaard ;
Santanam, Lakshmi ;
Sherouse, George W. ;
Shi, Jie ;
Stathakis, Sotirios .
MEDICAL PHYSICS, 2021, 48 (05) :E44-E64