Postoperative maxilary stability after Le Fort I osteotomy using a u-HA/PLLA system: threedimensional analysis by surface superimposition based on virtual Le Fort I osteotomy

被引:0
|
作者
Yamamoto, S. [1 ]
Iwadate, R. [2 ]
Maeda, K. [1 ]
Taniike, N. [1 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Oral & Maxillofacial Surg, 2-1-1 Minatojima Minamimachi,Chuo Ku, Kobe, Hyogo 6500047, Japan
[2] Josai Univ, Fac Pharm & Pharmaceut Sci, Sakado, Saitama, Japan
关键词
Orthognathic surgery; Le Fort os- teotomy; Bone plates; Absorbable implants; Three-dimensional imaging; 3-DIMENSIONAL ANALYSIS; ORTHOGNATHIC SURGERY; MAXILLARY STABILITY; SKELETAL STABILITY; PLATES; TITANIUM; SCREWS;
D O I
10.1016/j.ijom.2024.09.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The postoperative stability achieved with Le Fort I osteotomy (LFI) using bioabsorbable systems remains controversial. A new method - multipoint measurement method - was devised for detailed three-dimensional examination of postoperative stability following LFI, and the stability after LFI when using SuperFIXSORB-MX made of u-HA/PLLA was investigated. Thirty-one patients who underwent LFI using SuperFIXSORB-MX were evaluated retrospectively. The patients were divided into four malocclusion types: open bite, mandibular retrognathia, mandibular protrusion, and facial asymmetry. Seven maxillary reference points were measured three-dimensionally using computed tomography scans obtained preoperatively (T0), 4 days post-surgery (T1), and 1 year post-surgery (T2). Surgical changes (T1-T0) and the postoperative discrepancy (T2-T1) of the maxilla were analysed to evaluate postoperative stability by surface superimposition of the virtual LFI segments. Postoperative discrepancy was the largest for the facial asymmetry type, ranging from 0.75 +/- 0.45 mm to 0.98 +/- 0.52 mm in threedimensional distance (minimum to maximum mean +/- standard deviation values for the individual reference points). The relapse at U1 was 16% in the transverse axis, and the anterior nasal spine moved further upward by 17% of the amount of movement of the maxilla. Fixation with SuperFIXSORB-MX was considered to be within clinically acceptable limits.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 50 条
  • [41] Assessment of bone healing after Le Fort I osteotomy with 3-dimensional computed tomography
    Ueki, Koichiro
    Miyazaki, Mao
    Okabe, Katsuhiko
    Mukozawa, Aya
    Marukawa, Kohei
    Moroi, Akinori
    Nakagawa, Kiyomasa
    Yamamoto, Etsuhide
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2011, 39 (04) : 237 - 243
  • [42] Skeletal stability of Le Fort I osteotomy in patients with unilateral cleft lip and palate
    Heliövaara, A
    Ranta, R
    Hukki, JH
    Rintala, A
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2001, 35 (01): : 43 - 49
  • [43] Three-dimensional evaluation of the alar cinch suture after Le Fort I osteotomy
    van Loon, B.
    Verhamme, L.
    Xi, T.
    de Koning, M. J. J.
    Berge, S. J.
    Maal, T. J. J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (10) : 1309 - 1314
  • [44] Maxillary Aseptic Necrosis After Le Fort I Osteotomy: A Case Report and Literature Review
    Pereira, Felipe Ladeira
    Faria Yaedu, Renato Yassutaka
    Sant'Ana, Adriana Passanezi
    Sant'Ana, Eduardo
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (06) : 1402 - 1407
  • [45] Biomechanical testing of zirconium dioxide osteosynthesis system for Le Fort I advancement osteotomy fixation
    Hingsammer, Lukas
    Grillenberger, Markus
    Schagerl, Martin
    Malek, Michael
    Hunger, Stefan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 34 - 39
  • [46] Comparison of Skeletal Stability after Le Fort I Osteotomy With Bone Fixation Using Biodegradable and Titanium Systems: A Retrospective Study
    Shido, Rena
    Ohba, Seigo
    Moriuchi, Emi
    Yasuda, Gou
    Hara, Masahito
    Narahara, Shun
    Ogata, Kinuko
    Yoshida, Noriaki
    Yamada, Tomohiro
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (05) : 1513 - 1516
  • [47] Non-union of the maxilla: A rare complication after Le Fort I osteotomy
    Imholz, B.
    Richter, M.
    Dojcinovic, I.
    Hugentobler, M.
    REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2010, 111 (5-6) : 270 - 275
  • [48] Bone healing after Le Fort I osteotomy with SSRO, using uHA/PLLA plates and screws, in class II and III patients
    Ueki, Koichiro
    Yoshizawa, Kunio
    Moroi, Akinori
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (09) : 1338 - 1342
  • [49] Evaluation of the Pterygomaxillary Separation Pattern in Le Fort I Osteotomy Using Different Cutting Instruments
    Bilge, Suheyb
    Kaba, Yusuf Nuri
    Demirbas, Ahmet Emin
    Kutuk, Nukhet
    Kilic, Erdem
    Alkan, Alper
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 78 (10) : 1820 - 1831
  • [50] Assessment of Nasal Septum Change after Le Fort I Osteotomy Using Cone Beam Computed Tomography
    Rattana-arpha, Pornpop
    Boonsiriseth, Kiatanant
    Kretapirom, Kornkamol
    Kriangcherdsak, Yutthasak
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (04) : 799 - 805