Postoperative maxilary stability after Le Fort I osteotomy using a u-HA/PLLA system: threedimensional analysis by surface superimposition based on virtual Le Fort I osteotomy

被引:0
作者
Yamamoto, S. [1 ]
Iwadate, R. [2 ]
Maeda, K. [1 ]
Taniike, N. [1 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Oral & Maxillofacial Surg, 2-1-1 Minatojima Minamimachi,Chuo Ku, Kobe, Hyogo 6500047, Japan
[2] Josai Univ, Fac Pharm & Pharmaceut Sci, Sakado, Saitama, Japan
关键词
Orthognathic surgery; Le Fort os- teotomy; Bone plates; Absorbable implants; Three-dimensional imaging; 3-DIMENSIONAL ANALYSIS; ORTHOGNATHIC SURGERY; MAXILLARY STABILITY; SKELETAL STABILITY; PLATES; TITANIUM; SCREWS;
D O I
10.1016/j.ijom.2024.09.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The postoperative stability achieved with Le Fort I osteotomy (LFI) using bioabsorbable systems remains controversial. A new method - multipoint measurement method - was devised for detailed three-dimensional examination of postoperative stability following LFI, and the stability after LFI when using SuperFIXSORB-MX made of u-HA/PLLA was investigated. Thirty-one patients who underwent LFI using SuperFIXSORB-MX were evaluated retrospectively. The patients were divided into four malocclusion types: open bite, mandibular retrognathia, mandibular protrusion, and facial asymmetry. Seven maxillary reference points were measured three-dimensionally using computed tomography scans obtained preoperatively (T0), 4 days post-surgery (T1), and 1 year post-surgery (T2). Surgical changes (T1-T0) and the postoperative discrepancy (T2-T1) of the maxilla were analysed to evaluate postoperative stability by surface superimposition of the virtual LFI segments. Postoperative discrepancy was the largest for the facial asymmetry type, ranging from 0.75 +/- 0.45 mm to 0.98 +/- 0.52 mm in threedimensional distance (minimum to maximum mean +/- standard deviation values for the individual reference points). The relapse at U1 was 16% in the transverse axis, and the anterior nasal spine moved further upward by 17% of the amount of movement of the maxilla. Fixation with SuperFIXSORB-MX was considered to be within clinically acceptable limits.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 24 条
[1]   Comparison between traditional 2-dimensional cephalometry and a 3-dimensional approach on human dry skulls [J].
Adams, GL ;
Gansky, SA ;
Miller, AJ ;
Harrell, WE ;
Hatcher, DC .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 126 (04) :397-409
[2]  
BELL WH, 1975, J ORAL SURG, V33, P412
[3]   LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[4]   A Randomized Clinical Trial of Biodegradable and Titanium Fixation Systems in Maxillofacial Surgery [J].
Buijs, G. J. ;
van Bakelen, N. B. ;
Jansma, J. ;
de Visscher, J. G. A. M. ;
Hoppenreijs, T. J. M. ;
Bergsma, J. E. ;
Stegenga, B. ;
Bos, R. R. M. .
JOURNAL OF DENTAL RESEARCH, 2012, 91 (03) :299-304
[5]   Stability of skeletal class III malocclusion after combined maxillary and mandibular procedures: Titanium versus resorbable plates and screws for maxillary fixation [J].
Costa, F ;
Robiony, M ;
Zorzan, E ;
Zerman, N ;
Politi, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (04) :642-651
[6]   LeFort I maxillary advancement: 3-year stability and risk factors for relapse [J].
Dowling, PA ;
Espeland, L ;
Sandvik, L ;
Mobarak, KA ;
Hogevold, HE .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (05) :560-567
[7]   Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances [J].
Gareb, Barzi ;
Van Bakelen, Nico B. ;
Vissink, Arjan ;
Bos, Ruud R. M. ;
Van Minnen, Baucke .
POLYMERS, 2022, 14 (14)
[8]   Efficacy and morbidity of biodegradable versus titanium osteosyntheses in orthognathic surgery: A systematic review with meta-analysis and trial sequential analysis [J].
Gareb, Barzi ;
van Bakelen, Nico B. ;
Dijkstra, Pieter U. ;
Vissink, Arjan ;
Bos, Ruud R. M. ;
van Minnen, Baucke .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2021, 129 (05)
[9]   Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures [J].
Haers, PE ;
Sailer, HF .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (06) :363-372
[10]   Accuracy of a Computer-Aided Surgical Simulation Protocol for Orthognathic Surgery: A Prospective Multicenter Study [J].
Hsu, Sam Sheng-Pin ;
Gateno, Jaime ;
Bell, R. Bryan ;
Hirsch, David L. ;
Markiewicz, Michael R. ;
Teichgraeber, John F. ;
Zhou, Xiaobo ;
Xia, James J. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (01) :128-142