New Refrigerant Developments For Very Low Temperature Refrigeration

被引:0
|
作者
Low, Robert [1 ]
Seeton, Christopher J. [2 ]
机构
[1] Koura Global, Runcorn WA7 4QX, England
[2] Koura Global, Waltham, MA USA
来源
7TH IIR 2022 INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN 2022 | 2022年
关键词
Refrigeration; Carbon Dioxide; System Testing; COP; GWP;
D O I
10.18462/iir.iccc2022.1138
中图分类号
O414.1 [热力学];
学科分类号
摘要
Very Low Temperature cascade refrigeration is of increasing importance in ensuring a suitable cold chain for high value materials such as vaccines or premium seafood. Koura is developing new refrigerant options for system designers including R-473A. This refrigerant was designed as a non-flammable "near drop-in" alternative to R-23 or R-508B, with Global Warming Potential (GWP) below 2000. It contains 60% of R-744 but can operate well below that refrigerant's triple point. This paper presents information on R-473A in use including: performance testing, oil and materials compatibility studies and analysis of its effective temperature range. Options will be discussed for further reduction in GWP to enable non-flammable refrigerants or weakly flammable refrigerants capable of operating at -90 degrees C evaporator conditions.
引用
收藏
页码:282 / 288
页数:7
相关论文
共 50 条
  • [1] LOW GWP REFRIGERANT R454A FOR COMMERCIAL REFRIGERATION
    Flohr, Felix
    Arimoto, Hitomi
    Ohkubo, Shun
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 224 - 230
  • [2] Performance comparison of low GWP refrigerant alternatives in a commercial refrigeration application
    Zgliczynski, Marek
    Sedliak, Jozef
    Hense, Daniel
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 1174 - 1182
  • [3] Refrigerant charge influence on the performance of a transcritical CO2 system with flash-tank for low-temperature refrigeration
    Avila-Gutierrez, Miguel
    Mejias, Manuel Delgado
    Perez, Bernardo Peris
    Besagni, Giorgio
    Lissen, Jose Manuel Salmeron
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [4] Commercial refrigeration system using CO2 as the refrigerant
    Girotto, S
    Minetto, S
    Neksa, P
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (07): : 717 - 723
  • [5] Thermodynamic Assessment of Using Water as a Refrigerant in Cascade Refrigeration Systems With Other Environmentally Friendly Refrigerants
    Alkhulaifi, Yousif M.
    Mokheimer, Esmail M. A.
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (02):
  • [6] Effect of new generation refrigerant selection to the low temperature circuit efficiency in cascade systems
    Bayrakci, Hilmi Cenk
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2011, 27 (01): : 15 - 24
  • [7] Energy and irreversibility analysis of a cascade refrigeration system for various refrigerant couples
    Kilicarslan, A.
    Hosoz, M.
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) : 2947 - 2954
  • [8] New refrigeration system using CO2 vapor-solid as refrigerant
    Huang D.
    Ding G.
    Quack H.
    Frontiers of Energy and Power Engineering in China, 2008, 2 (4): : 494 - 498
  • [9] Evaluation of the performance of solid sorption refrigeration systems using carbon dioxide as refrigerant
    Zhong, Y.
    Critoph, R. E.
    Thorpe, R.
    APPLIED THERMAL ENGINEERING, 2006, 26 (16) : 1807 - 1811
  • [10] Effect of Refrigerant Type and Insulation Thickness on Refrigeration Systems of Land and Sea Vehicles
    Dalkilic, Ahmet Selim
    Celen, Ali
    Cebi, Alican
    Wongwises, Somchai
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2016, 62 (04): : 252 - 259