Diagnostic Capability of Pattern Electroretinogram and Three Circumpapillary Retinal Nerve Fiber Layer Thickness Circle Diameter Scans in Glaucoma Suspects

被引:0
作者
Tirsi, Andrew [1 ,2 ]
Tsai, Joby [3 ]
Abizadeh, Aaron [2 ]
Kacaj, Danielle [4 ]
Procyk, Oksana [1 ]
Gliagias, Vasiliki [2 ]
Leung, Nicholas [2 ]
Yang, Hanwen [2 ]
Park, Sung Chul [1 ,2 ]
Tello, Celso [1 ,2 ]
机构
[1] Northwell Hlth, Dept Ophthalmol, Manhattan Eye Ear & Throat Hosp, 210 East 64th St, New York, NY 10065 USA
[2] Northwell Hlth, Donald & Barbara Zucker Sch Med Hofstra, Hempstead, NY USA
[3] Broward Hlth, Dept Ophthalmol, Ft Lauderdale, FL USA
[4] Cornell Univ, Ithaca, NY USA
来源
CLINICAL OPHTHALMOLOGY | 2025年 / 19卷
关键词
glaucoma suspects; glaucoma; PERG; SD-OCT; RNFL; OPTICAL COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN; PERG; DAMAGE; CELLS; OCT;
D O I
10.2147/OPTH.S483055
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the diagnostic capability of pattern electroretinography (PERG) and varying circumpapillary optical coherence tomography (OCT) scan diameters in glaucoma suspects (GS). Methods: This is a prospective, cross-sectional study. Circumpapillary retinal nerve fiber layer thickness (RNFLT) was measured using spectral domain OCT in 49 eyes from 26 patients (36 normal, 13 GS) in three circle diameters (3.5, 4.1, and 4.7 mm). PERG measurements (Magnitude [Mag], MagnitudeD [MagD], MagnitudeD/Magnitude [MagD/Mag] ratio) were used. Based on clinical examination, participants were classified as controls or GS. Independent t-test and areas under the receiver operating characteristic curve (AUC) were obtained to determine the diagnostic capability of PERG and OCT. Results: Independent t-test revealed significant differences between controls and GS in age, sex, central corneal thickness (CCT), all PERG parameters, and global RNFLT (gRNFLT) in three circle diameters. All PERG parameters were correlated to all RNFLT sectors (r > 0.291; p < 0.041), except in the temporal and nasal sectors of the three circle scans. Spearman rho was highest in 3.5 and lowest in 4.7 mm circle scan. AUC demonstrated 3.5 mm gRNFLT had the highest diagnostic capability (AUC = 0.877), followed by 4.1 mm gRNFLT (AUC = 0.852), and 4.7 mm gRNFLT (AUC = 0.821). MagD showed the foremost diagnostic capability (AUC = 0.81), followed by Mag (AUC = 0.799) and MagD/Mag (AUC = 0.762). Conclusion: Global, superior, and inferior RNFLT in 3.5 and 4.1 mm diameters, and MagD performed best in discriminating GS from controls, suggesting that a larger scan of 4.1 mm may be equally useful in glaucoma diagnosis as the conventional 3.5 mm diameter. We recommend using PERG with OCT of 3.5 or 4.1 mm diameters for glaucoma suspect diagnosis.
引用
收藏
页码:235 / 247
页数:13
相关论文
共 56 条
  • [1] Correlation of Retinal Nerve Fiber Layer Thickness and Visual Fields in Glaucoma: A Broken Stick Model
    Alasil, Tarek
    Wang, Kaidi
    Yu, Fei
    Field, Matthew G.
    Lee, Hang
    Baniasadi, Neda
    de Boer, Johannes F.
    Coleman, Anne L.
    Chen, Teresa C.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (05) : 953 - 959
  • [2] Steady-state pattern electroretinogram and short-duration transient visual evoked potentials in glaucomatous and healthy eyes
    Amarasekera, Dilru C.
    Resende, Arthur F.
    Waisbourd, Michael
    Puri, Sanjeev
    Moster, Marlene R.
    Hark, Lisa A.
    Katz, L. Jay
    Fudemberg, Scott J.
    Mantravadi, Anand V.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (01) : 54 - 61
  • [3] Update on the pattern electroretinogram in glaucoma
    Bach, Michael
    Hoffmann, Michael B.
    [J]. OPTOMETRY AND VISION SCIENCE, 2008, 85 (06) : 386 - 395
  • [4] Pattern ERG as an early glaucoma indicator in ocular hypertension: A long-term, prospective study
    Bach, Michael
    Unsoeld, Anke S.
    Philippin, Heiko
    Staubach, Flemming
    Maier, Philip
    Walter, Hans S.
    Bomer, Thomas G.
    Funk, Jens
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) : 4881 - 4887
  • [5] Angular Location of Retinal Nerve Fiber Layer Defect: Association With Myopia and Open-Angle Glaucoma
    Bak, Eunoo
    Lee, Kyoung Min
    Kim, Martha
    Oh, Sohee
    Kim, Seok Hwan
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (11)
  • [6] Progressive Loss of Retinal Ganglion Cell Function Precedes Structural Loss by Several Years in Glaucoma Suspects
    Banitt, Michael R.
    Ventura, Lori M.
    Feuer, William J.
    Savatovsky, Eleonore
    Luna, Gabriel
    Shif, Olga
    Bosse, Brandon
    Porciatti, Vittorio
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (03) : 2346 - 2352
  • [7] Enhanced Glaucoma Staging System (GSS 2) for classifying functional damage in glaucoma
    Brusini, P
    Filacorda, S
    [J]. JOURNAL OF GLAUCOMA, 2006, 15 (01) : 40 - 46
  • [8] Ganglion cell loss in early glaucoma, as assessed by photopic negative response, pattern electroretinogram, and spectral-domain optical coherence tomography
    Cvenkel, Barbara
    Sustar, Maja
    Perovsek, Darko
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2017, 135 (01) : 17 - 28
  • [9] Glaucoma: the retina and beyond
    Davis, Benjamin Michael
    Crawley, Laura
    Pahlitzsch, Milena
    Javaid, Fatimah
    Cordeiro, Maria Francesca
    [J]. ACTA NEUROPATHOLOGICA, 2016, 132 (06) : 807 - 826
  • [10] Glaucoma Diagnostic Capability of Circumpapillary Retinal Nerve Fiber Layer Thickness in Circle Scans With Different Diameters
    Ghassibi, Mark P.
    Chien, Jason L.
    Patthanathamrongkasem, Thipnapa
    Abumasmah, Ramiz K.
    Rosman, Michael S.
    Skaat, Alon
    Tello, Celso
    Liebmann, Jeffrey M.
    Ritch, Robert
    Park, Sung Chul
    [J]. JOURNAL OF GLAUCOMA, 2017, 26 (04) : 335 - 342