Application of Kalman Filter in Gas Detection by Cavity Ring-Down Spectroscopy

被引:1
作者
Li, De-hao [1 ]
Wang, Dan [1 ]
Li, Zhi-yan [1 ]
Chen, Hao [2 ]
机构
[1] Anhui Univ Technol, Sch Microelect & Data Sci, Maanshan 243000, Peoples R China
[2] Suzhou Univ Sci & Technol, Sch Mech Engn, Suzhou 215000, Peoples R China
关键词
Cavity ring down spectroscopy; Kalman filters; Gas measurements; Noise reductions; Detection limit; TIME; NO3;
D O I
10.3964/j.issn.1000-0503(2024)10-2727-06
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Cavity Ring Down Spectroscopy (CRDS) is a highly sensitive trace gas concentration measurement technique in which the processing of ring down time is crucial. This paper adopts the Kalman filter process the cavity ring down spectroscopy to seduce the measurement error introduced by noise durin,, the collection and real-time measurement rocess. This method preprocesses with the traditional filtering method to obtain the observation noise covariance (R) of the Kalman filter Barameters adjusts the process excitation noise covariance (Q), and evaluates the filtering effect to optimize the measurement results. Using simulated ring down signals with white noise, the linear regression summation method (IRS) fits the background rendering downtimesto perform Kalman filtering. From four aspects of mean, standard deviation, residual standard deviation IRMSE) and different noise levels, the appropriate Q value range is obtained, which is less than 1x 10 and 0.001. Fespectively. An experimental gas detection system based on CRDS technology is constructed, using a 405 nm eenter wavelength diode laser and a high reflectivity mirror with a reflectivity of over 99.99% with NO, as the target gas, and the background ring down time and ring down time are processed and analyzed using Kalman filtering. The experimental results show that: (1) Selecting a Q value less than 1x10 for Kalman filtering of the background ring down time increases the lowest detection limit By 9. 12 times and reaches 4.9x10 "after filterings (2) Taking Q value of 0.001 for processing the ring down time retains the time response information and achieves significant noise reduction (3) The system's time resolution is 1 and compared to the method of reducing time resolution to improve detection limit in the past the Kalman filtering method improves the system's Jensitivity. The agreement between experimental and simulated results verifies the effectiveness of Kalman filtering in stability and noise reduction. Applying the Kalman filtering method in the CRDS spectroscopic detection of gases is practical and provides methods and references for optimizing other gas measurement results.
引用
收藏
页码:2727 / 2732
页数:6
相关论文
共 24 条
[1]  
Almagbile A., 2010, J. Glob. Position. Syst, V9, P33, DOI [DOI 10.5081/JGPS.9.1.33, 10.5081/jgps.9.1.33]
[2]   Cavity ring-down spectroscopy: Experimental schemes and applications [J].
Berden, G ;
Peeters, R ;
Meijer, G .
INTERNATIONAL REVIEWS IN PHYSICAL CHEMISTRY, 2000, 19 (04) :565-607
[3]   Cavity ring-down spectroscopy for atmospheric trace gas detection:: application to the nitrate radical (NO3) [J].
Brown, SS ;
Stark, H ;
Ravishankara, AR .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3) :173-182
[4]   CRDS with a VECSEL for broad-band high sensitivity spectroscopy in the 2.3 μm window [J].
Cermak, P. ;
Chomet, B. ;
Ferrieres, L. ;
Vasilchenko, S. ;
Mondelain, D. ;
Kassi, S. ;
Campargue, A. ;
Denet, S. ;
Lecocq, V. ;
Myara, M. ;
Cerutti, L. ;
Garnache, A. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (08)
[5]  
DALEY R, 1993, MON WEATHER REV, V121, P1554, DOI 10.1175/1520-0493(1993)121<1554:SCOKFS>2.0.CO
[6]  
2
[7]   Kalman filter-based air quality forecast adjustment [J].
De Ridder, Koen ;
Kumar, Ujjwal ;
Lauwaet, Dirk ;
Blyth, Lisa ;
Lefebvre, Wouter .
ATMOSPHERIC ENVIRONMENT, 2012, 50 :381-384
[8]   Diode laser cavity ring-down spectroscopy for atmospheric NO3 radical measurement [J].
Hu Ren-Zhi ;
Wang Dan ;
Xie Pin-Hua ;
Ling Liu-Yi ;
Qin Min ;
Li Chuan-Xin ;
Liu Jian-Guo .
ACTA PHYSICA SINICA, 2014, 63 (11)
[9]   Applications of Kalman filtering to real-time trace gas concentration measurements [J].
Leleux, DP ;
Claps, R ;
Chen, W ;
Tittel, FK ;
Harman, TL .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 74 (01) :85-93
[10]  
LI Jin-yi, 2022, Acta Optica Sinica, V42, P207