Sensitizing performance of air purifiers for the high-rise commercial buildings in urban core

被引:0
作者
Budde, Sandeep [1 ,2 ]
Chani, Prabhjot Singh [2 ]
Agrawal, Sandeep [1 ]
机构
[1] Univ Alberta, Sch Urban & Reg Planning, Urban Environm Observ, Edmonton, AB, Canada
[2] Indian Inst Technol IIT, Dept Architecture & Planning, Built Environm Lab, Roorkee, India
来源
FRONTIERS IN SUSTAINABLE CITIES | 2025年 / 6卷
关键词
air purifiers; urban air pollution; smart building guidelines; co-simulation mode; energy plus; ENERGY MANAGEMENT; POLLUTION; QUALITY; EXPOSURE; IMPACT;
D O I
10.3389/frsc.2024.1469803
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
There are thousands of pollution monitoring stations which are recording the data 24x7, the present research question is using this data to solve bring out a relationship between natural ventilation and air conditioning. Recently, WHO reported that 14 out of the top 15 most polluted cities are in India. Every year there is a loss of 6.2% to the global economy due to air pollution. The recent urban PM2.5 smog spread over the whole of north India covering about 50% of the country's population. This event has been increasing the use of air purifiers and affecting the building energy performance. Most air purifiers (PM 10 and PM 2.5) are energy-intensive but are not always equipped with sensors. In commercial buildings, air purifiers are operated based on publicly relayed pollution information. The air pollutants that infiltrate into buildings are based on leaks, cracks, quality of building construction and pressure differences. Since indoor pollution levels are less than outdoor pollution levels, usage of air purifiers based on outdoor information leads to overperformance and hence energy wastage. Therefore, there is a need for optimization in sensitizing the performance of air purifiers at the building level. This study intends to assess the role of building airtightness and air purifier automation in lessening the air purifiers' electricity consumption in urban areas. Transient building simulation tools do not account for infiltrated pollution levels directly. Virtually evaluating the energy savings through air purifier automation and the building's airtightness would not be a straightforward assessment. The following paper uses EnergyPlus Energy Management System Class along with air pollution data monitored to model and simulate the Business-as-usual (BAU) and proposed Automation scenarios.
引用
收藏
页数:10
相关论文
共 51 条
[1]   Experimental Application of Methods to Compute Solar Irradiance and Cell Temperature of Photovoltaic Modules [J].
Abe, Caio Felippe ;
Dias, Joao Batista ;
Notton, Gilles ;
Faggianelli, Ghjuvan Antone .
SENSORS, 2020, 20 (09)
[2]  
Abougendia S. M., 2020, WIT Trans. Ecol. Environ, V241, P309, DOI [10.2495/SDP200251, DOI 10.2495/SDP200251, 10.2495/sdp200251]
[3]   Biomonitoring of human exposures to chlorinated derivatives and structural analogs of bisphenol A [J].
Andra, Syam S. ;
Charisiadis, Pantelis ;
Arora, Manish ;
van Vliet-Ostaptchouk, Jana V. ;
Makris, Konstantinos C. .
ENVIRONMENT INTERNATIONAL, 2015, 85 :352-379
[4]   Economic Costs of Childhood Lead Exposure in Low- and Middle-Income Countries [J].
Attina, Teresa M. ;
Trasande, Leonardo .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2013, 121 (09) :1097-1102
[5]  
Bapat S., 2012, Microeconomics of competitiveness Tamil Nadu automotive cluster Harvard Business School Spring 2012 section
[6]   Low-income housing layouts under socio-architectural complexities: A parametric study for sustainable slum rehabilitation [J].
Bardhan, Ronita ;
Debnath, Ramit ;
Malik, Jeetika ;
Sarkar, Ahana .
SUSTAINABLE CITIES AND SOCIETY, 2018, 41 :126-138
[7]   Children's microenvironmental exposure to PM2.5and ozone and the impact of indoor air filtration [J].
Barkjohn, Karoline K. ;
Norris, Christina ;
Cui, Xiaoxing ;
Fang, Lin ;
He, Linchen ;
Schauer, James J. ;
Zhang, Yinping ;
Black, Marilyn ;
Zhang, Junfeng ;
Bergin, Michael H. .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2020, 30 (06) :971-980
[8]   Framework for Evaluating and Mitigating Industrial Air Pollution in India: Systematic Review of Concepts and Unmet Needs [J].
Budde, Sandeep ;
Chani, P. S. ;
Agrawal, Sandeep .
JOURNAL OF HAZARDOUS TOXIC AND RADIOACTIVE WASTE, 2025, 29 (01)
[9]   Utilising GIS for studying urban entropy, population dynamics, and ventilation disparity: A case study of changing land use, land cover, and socially vulnerable hotspots in Hyderabad, India [J].
Budde, Sandeep ;
Agrawal, Sandeep ;
Chani, P. S. .
PHYSICS AND CHEMISTRY OF THE EARTH, 2024, 136
[10]   Comprehensive analysis of classroom microclimate in context to health-related national and international indoor air quality standards [J].
Caciora, Tudor ;
Ilies, Alexandru ;
Berdenov, Zharas ;
Al-Hyari, Hadeel Sa'ad ;
Ilies, Dorina Camelia ;
Safarov, Bahodirhon ;
Hassan, Thowayeb H. ;
Herman, Grigore Vasile ;
Hodor, Nicolaie ;
Bilalov, Bahadur ;
Peres, Ana Cornelia .
FRONTIERS IN PUBLIC HEALTH, 2024, 12