A prospective study on the effect of tumor shrinkage on exit fluence gamma pass rate in high precision radiotherapy and influence of phantom setup error in patient-specific quality assurance

被引:0
作者
Tiwari, Arnav [1 ]
Das, Saikat [1 ]
Pandey, Vindhyavasini P. [1 ]
Kharade, Vipin [1 ]
Gupta, Manish [1 ]
Pasricha, Rajesh [1 ]
机构
[1] All India Inst Med Sci, Dept Radiat Oncol, Bhopal 462020, Madhya Pradesh, India
关键词
Gamma pass rate; IMRT; patient-specific QA; Quality assurance; ADAPTIVE RADIOTHERAPY; RADIATION-THERAPY; PORTAL DOSIMETRY; HEAD; PREDICT; BEAM;
D O I
10.4103/jcrt.jcrt_2472_23
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Objective parameters for decision on adaptive radiotherapy depend on patient, tumor and treatment related factors. Present study reports geometric uncertainties occurring during high precision radiotherapy, beam fluence analysis and serial exit dose measurement as a patient-specific tool for adaptive radiotherapy. Materials and Methods: Serial exit dose fluence of 24 patients (at baseline and mid-treatment) undergoing IMRT/VMAT treatment were measured. Baseline and midtreatment exit dose evaluation was done using gafchromic films in predefined region of interest. Difference of volume of GTV at baseline (from simulation CT scan) and midtreatment CBCT scan was calculated (Delta GTV). Results: Population based systematic errors (mm) were 4.15, 2.26, 0.88 and random errors (mm) were 2.56, 3.69, and 2.03 in mediolateral (ML), craniocaudal (CC) and anteroposterior (AP) directions respectively. Gamma pass rate reduced with incremental shift. For a 5 mm shift, maximum deviation was found in anteroposterior axis (22.16 7.50) and lowest in mediolateral axis (12.85 +/- 4.95). On serial measurement of exit dose fluence, tumor shrinkage significantly influenced gamma pass rate. The mean gamma pass rate was significantly different between groups with 50% shrinkage of tumor volume (86.36 vs 96.24, P = 0.008, on multivariate analysis P = 0.026). Conclusion: Rapid fall of gamma pass rate was observed for set up error of >= 3 mm. Serial measurement of exit dose fluence by radiochromic film is a feasible method of exit dose comparison in IMRT/VMAT, where EPID dosimetry is not available with linear accelerator configuration. Our study suggests that there is a significant difference between gamma pass rates of baseline and mid treatment exit dose fluence with greater than 50% tumor shrinkage.
引用
收藏
页码:935 / 942
页数:8
相关论文
共 30 条
[11]   Comparison of sources of exit fluence variation for IMRT [J].
Gardner, Joseph K. ;
Clews, Luke ;
Gordon, J. James ;
Wang, Song ;
Greer, Peter B. ;
Siebers, Jeffrey V. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19) :N451-N458
[12]   Set-up verification using portal imaging; review of current clinical practice [J].
Hurkmans, CW ;
Remeijer, P ;
Lebesque, JV ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :105-120
[13]   A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems [J].
Hussein, Mohammad ;
Rowshanfarzad, Pejman ;
Ebert, Martin A. ;
Nisbet, Andrew ;
Clark, Catharine H. .
RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) :370-376
[14]  
Low Daniel A., 2010, Journal of Physics: Conference Series, V250, DOI 10.1088/1742-6596/250/1/012071
[15]   Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry [J].
Mccaw, Travis J. ;
Micka, John A. ;
DeWerd, Larry A. .
MEDICAL PHYSICS, 2014, 41 (05)
[16]   EPID-based dosimetry and its relation to other 2D and 3D dose measurement techniques in radiation therapy [J].
Mijnheer, B. .
9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
[17]   Inter-fractional entrance dose monitoring as quality assurance using Gafchromic EBT3 film [J].
Moon, Sun Young ;
Jo, Yunhui ;
Seo, Jaehyeon ;
Shin, Dongho ;
Yoon, Myonggeun .
JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2022, 18 (04) :1152-1158
[18]   Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels [J].
Nelms, Benjamin E. ;
Chan, Maria F. ;
Jarry, Genevieve ;
Lemire, Matthieu ;
Lowden, John ;
Hampton, Carnell ;
Feygelman, Vladimir .
MEDICAL PHYSICS, 2013, 40 (11)
[19]   Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors [J].
Nelms, Benjamin E. ;
Zhen, Heming ;
Tome, Wolfgang A. .
MEDICAL PHYSICS, 2011, 38 (02) :1037-1044
[20]   Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55 [J].
Niroomand-Rad, A ;
Blackwell, CR ;
Coursey, BM ;
Gall, KP ;
Galvin, JM ;
McLaughlin, WL ;
Meigooni, AS ;
Nath, R ;
Rodgers, JE ;
Soares, CG .
MEDICAL PHYSICS, 1998, 25 (11) :2093-2115