Diagnostic performance of tomosynthesis plus synthetic mammography versus full-field digital mammography with or without tomosynthesis in breast cancer screening: A systematic review and meta-analysis

被引:0
作者
Hamad, Wasim [1 ]
Michell, Michael J. [2 ,3 ]
Myles, Jonathan P. [1 ]
Gilbert, Fiona J. [4 ]
Chen, Yan [5 ]
Jin, Huajie [2 ,3 ]
Loveland, John [6 ]
Halling-Brown, Mark [6 ]
Satchithananda, Keshthra [2 ,3 ]
Morel, Juliet [2 ,3 ]
Wasan, Rema [2 ,3 ]
Taylor, Caroline [7 ]
Sharma, Nisha [8 ]
Valencia, Alexandra [9 ]
Teh, Will [10 ]
Majid, Faisal [11 ]
De Visser, Ronald M. [2 ,3 ]
Iqbal, Asif [2 ,3 ]
Duffy, Stephen W. [1 ]
机构
[1] Queen Mary Univ London, Wolfson Inst Populat Hlth, London, England
[2] Kings Coll Hosp London, Breast Radiol Dept, London, England
[3] Kings Coll Hosp London, Natl Breast Training Ctr, London, England
[4] Univ Cambridge, Sch Clin Med, Dept Radiol, Cambridge, England
[5] Univ Nottingham, Appl Vis Res Ctr, Nottingham, England
[6] Royal Surrey Cty Hosp, Sci Comp, Guildford, England
[7] Jarvis Breast Ctr, Guildford, England
[8] Leeds Teaching Hosp NHS Trust, Breast Screening Unit, Leeds, England
[9] Bristol Breast Care Ctr, Avon Breast Screening Unit, Bristol, England
[10] Edgware Community Hosp, North London Breast Screening Serv, London, England
[11] Sandwell & West Birmingham NHS Trust, Sandwell & Walsall Breast Screening Serv, Birmingham, England
关键词
breast cancer; digital breast tomosynthesis; screening; synthetic mammogram; SYNTHESIZED 2-DIMENSIONAL MAMMOGRAPHY; IMPLEMENTATION;
D O I
10.1002/ijc.35217
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Digital breast tomosynthesis (DBT) with full-field digital mammography (FFDM) exposes women to a higher radiation dose. A synthetic 2D mammogram (S2D) is a two-dimensional image constructed from DBT. We aim to evaluate the S2D performance when used alone or combined with DBT compared to FFDM alone or with DBT. Studies were included if they recruited screening participants and reported on S2D performance. Studies were excluded if they included symptomatic patients, imaging was for diagnostic purposes, or if participants had a breast cancer history. Meta-analyses for cancer detection rates (CDR) and Specificities were conducted where available. Differences in the performance of imaging modalities were calculated within individual studies, and these were pooled by meta-analysis. Out of 3241 records identified, 17 studies were included in the review and 13 in the meta-analysis. The estimated combined difference in CDRs per thousand among individual studies that reported on DBT plus S2D vs. FFDM and those reporting on DBT plus S2D versus DBT plus FFDM was 2.03 (95% CI 0.81-3.25) and - 0.15 (95% CI -1.17 to 0.86), respectively. The estimated difference in percent specificities was 1.13 (95% CI -0.06 to 2.31) in studies comparing DBT plus S2D and FFDM. In studies comparing DBT plus S2D and DBT plus FFDM, the estimated difference in specificities was 1.08 (95% CI 0.59-1.56). DBT plus S2D showed comparable accuracy to FFDM plus DPT and improved cancer detection to FFDM alone. Integrating S2D with DBT in breast cancer screening is safe and preserves performance. Digital breast tomosynthesis (DBT), when combined with full-field digital mammogram (FFDM), exhibits relatively high accuracy in breast cancer diagnosis. The combination, however, increases radiation exposure. This review evaluated the performance of DBT plus synthesized 2D (S2D), derived from reconstructed tomosynthesis images, as an alternative to DBT + FFDM. DBT + S2D was found to have a higher cancer detection rate compared to FFDM alone and exhibited superior specificity relative to DBT + FFDM. CDR, however, was similar for DBT + S2D and DBT + FFDM. DBT and S2D perform similarly to DBT combined with FFDM, while mitigating increased radiation exposure, suggesting that it is a safe and effective alternative.image
引用
收藏
页码:969 / 979
页数:11
相关论文
共 50 条
  • [21] Initial Experience with Combination Digital Breast Tomosynthesis Plus Full Field Digital Mammography or Full Field Digital Mammography Alone in the Screening Environment
    Destounis, Stamatia
    Arieno, Andrea
    Morgan, Renee
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2014, 4
  • [22] Benefit of adding digital breast tomosynthesis to digital mammography for breast cancer screening focused on cancer characteristics: a meta-analysis
    Yun, Seong Jong
    Ryu, Chang-Woo
    Rhee, Sun Jung
    Ryu, Jung Kyu
    Oh, Ji Young
    BREAST CANCER RESEARCH AND TREATMENT, 2017, 164 (03) : 557 - 569
  • [23] Comparing Tumor Characteristics and Rates of Breast Cancers Detected by Screening Digital Breast Tomosynthesis and Full-Field Digital Mammography
    Dang, Pragya A.
    Wang, Aijia
    Senapati, Gunjan M.
    Ip, Ivan K.
    Lacson, Ronilda
    Khorasani, Ramin
    Giess, Catherine S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (03) : 701 - 706
  • [24] Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications
    Clauser, Paola
    Nagl, Georg
    Helbich, Thomas H.
    Pinker-Domenig, Katja
    Weber, Michael
    Kapetas, Panagiotis
    Bernathova, Maria
    Baltzer, Pascal A. T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (12) : 2161 - 2168
  • [25] Interval cancer in the Cordoba Breast Tomosynthesis Screening Trial (CBTST): comparison of digital breast tomosynthesis plus digital mammography to digital mammography alone
    Pulido-Carmona, Cristina
    Romero-Martin, Sara
    Raya-Povedano, Jose Luis
    Cara-Garcia, Maria
    Font-Ugalde, Pilar
    Elias-Cabot, Esperanza
    Pedrosa-Garriguet, Margarita
    Alvarez-Benito, Marina
    EUROPEAN RADIOLOGY, 2024, 34 (08) : 5427 - 5438
  • [26] Breast tomosynthesis: A diagnostic addition to screening digital mammography
    El Bakry, Rehab Abdel Rahman
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (02) : 529 - 535
  • [27] Digital Breast Tomosynthesis versus MRI as an Adjunct to Full-Field Digital Mammography for Preoperative Evaluation of Breast Cancer according to Mammographic Density
    Kim, Haejung
    Yang, So Yeon
    Ahn, Joong Hyun
    Ko, Eun Young
    Ko, Eun Sook
    Han, Boo-Kyung
    Choi, Ji Soo
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (11) : 1031 - 1043
  • [28] Comparison of Full-Field Digital Mammography with Synthesized Mammography from Tomosynthesis in a Diagnostic population: Prospective Study
    Dhamija, Ekta
    Mohan, Supraja Laguduva
    Anand, Roshni
    Khan, Maroof Ahmad
    Deo, Sankaravamsam Venkata Suryanarayana
    Hari, Smriti
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2025, 35 (01) : 25 - 34
  • [29] A comparison between digital breast tomosynthesis and full-field digital mammography for the detection of breast cancers
    Woo Jung Choi
    Hak Hee Kim
    Sun Young Lee
    Eun Young Chae
    Hee Jung Shin
    Joo Hee Cha
    Byung Ho Son
    Sei Hyun Ahn
    Young-Wook Choi
    Breast Cancer, 2016, 23 : 886 - 892
  • [30] Interval breast cancer rates for digital breast tomosynthesis versus digital mammography population screening: An individual participant data meta-analysis
    Houssami, Nehmat
    Hofvind, Solveig
    Soerensen, Anne L.
    Robledo, Kristy P.
    Hunter, Kylie
    Bernardi, Daniela
    Lang, Kristina
    Johnson, Kristin
    Aglen, Camilla F.
    Zackrisson, Sophia
    ECLINICALMEDICINE, 2021, 34