Transcritical R744 Supermarket Refrigeration System Integrated with a Heat-Driven Ejector Chiller

被引:0
作者
Sengupta, Ayan [1 ]
Gullo, Paride [2 ]
Khorshidi, Vahid [3 ]
Dasgupta, Mani Sankar [1 ]
机构
[1] BITS, Dept Mech Engn, Smart Bldg Lab, Pilani 333031, Rajasthan, India
[2] Univ Southern Denmark SDU, Inst Mech & Elect Engn, Alsion 2, DK-6400 Sonderborg, Denmark
[3] Danfoss AS, Nordborgvej 81, DK-6430 Nordborg, Denmark
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 06期
关键词
supermarket; R744; R717; R718; R600a; refrigeration; subcooling; ejector; waste heat; parallel compression; PERFORMANCE; ENERGY;
D O I
10.3390/app15062955
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The subcooling potential of a novel R717-based waste heat-driven multi-ejector chiller (HEC) integrated with an R744 refrigeration system was evaluated for use in supermarkets. The performance was compared with an R744 refrigeration system coupled to R718- and R600a-based HECs, an R744 system equipped with parallel compression (PC), and a standard R744 booster system (CB) in various warm and hot climatic locations. Integration of the R717-based HEC was found to improve the coefficient of performance by 3.7% at 27 degrees C to 12.1% at 45 degrees C compared to the R718, and by 1.6% at 27 degrees C to 7.6% at 45 degrees C compared to the R600a-based system. The energy-saving potential of the R717 system (6.2% to 9.4%) was also found to be higher than that of the R718 (0.7% to 2.8%) and R600a systems (2.5% to 6.6%). The use of the existing high-pressure controllers of the CB system was found to impose a relatively lower penalty on the system performance compared to the controllers of the PC system. Although the integration of the R718 system incurred a significantly lower additional investment, the recovery time of the R600a-based HEC (2.3-4.8 years) was found to be the shortest.
引用
收藏
页数:27
相关论文
共 50 条
  • [41] Hybrid auto-cascade refrigeration system coupled with a heat-driven ejector cooling cycle
    Hao, Xinyue
    Wang, Lin
    Wang, Zhanwei
    Tan, Yingying
    Yan, Xiaona
    ENERGY, 2018, 161 : 988 - 998
  • [42] Study on the key ejector structures of the waste heat-driven ejector air conditioning system with R236fa as working fluid
    Zhang, Bo
    Song, Xutong
    Lv, Jinsheng
    Zuo, Jixue
    ENERGY AND BUILDINGS, 2012, 49 : 209 - 215
  • [43] Marine Heat-driven Ejector Refrigeration Machine for Airconditioning System with Thermal Energy Storage Unit
    Shestopalov, Kostyantyn
    Ierin, Volodymyr
    Konstantinov, Oleh
    Khliyeva, Olga
    NASE MORE, 2024, 71 (02): : 84 - 90
  • [44] THERMODYNAMIC ANALYSIS OF BI-EVAPORATOR EJECTOR REFRIGERATION CYCLE USING R744 AS NATURAL REFRIGERANT
    Kutlu, Cagri
    Unal, Saban
    Erdinc, Mehmet Tahir
    JOURNAL OF THERMAL ENGINEERING, 2016, 2 (02): : 735 - 740
  • [45] R744 refrigeration as an alternative for the supermarket sector in small tropical island developing states: The case of Mauritius
    Sooben, Darmanaden
    Purohit, Nilesh
    Mohee, Romeela
    Meunier, Francis
    Dasgupta, Mani Sankar
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 103 : 264 - 273
  • [46] Energy and environmental performance assessment of R744 booster supermarket refrigeration systems operating in warm climates
    Gullo, Paride
    Elmegaard, Brian
    Cortella, Giovanni
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 64 : 61 - 79
  • [47] Analysis of an R744 typical booster configuration, an R744 parallel-compressor booster configuration and an R717/R744 cascade refrigeration system for retail food applications. Part 1: Thermodynamic analysis
    Amaris, Carlos
    Tsamos, Konstantinos M.
    Tassou, Savvas A.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS INCLUDING WORKSHOP ON ENERGY RECOVERY CONVERSION AND MANAGEMENT;ICSEF 2018, 2019, 161 : 259 - 267
  • [48] Performance assessment of an off-the-shelf R744 heat pump equipped with an ejector
    Minetto, Silvia
    Brignoli, Riccardo
    Banasiak, Krzysztof
    Hafner, Armin
    Zilio, Claudio
    APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) : 568 - 575
  • [49] Experimental investigation on control methods and strategies for off-design operation of the transcritical R744 two-phase ejector cycle
    Lawrence, Neal
    Elbel, Stefan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 570 - 582
  • [50] Data-driven energy efficiency comparison between operating R744 and R448A supermarket refrigeration systems based on hybrid experimental-simulation analysis
    Tsimpoukis, Dimitrios
    Syngounas, Evangelos
    Bellos, Evangelos
    Koukou, Maria
    Tzivanidis, Christos
    Anagnostatos, Stavros
    Vrachopoulos, Michail Gr.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53